Iniciar sesión:
Votos - 4, Puntuación media: 3.5 ( )

Manual de usuario Lanier, modelo T 6055

Fabricar: Lanier
Tamaño del archivo: 15.34 kb
Nombre del archivo: cp239.pdf
Idioma del manual:en
Enlace gratuito para este manual disponible en la parte inferior de la página



Resumen del manual


E. Atlanta, GA 30345-2979 Emergency Telephone: (800) 526-4371 MATERIAL SAFETY DATA SHEET Section 1: Chemical Product and Company Information Identity: T 6055 Black Toner Product ID: 117- 0098 Synonyms & Common Names: Toner, Black Toner Uses: M6055, 6155, 6260, 6360 Copier Chemical Mixture Formula: MSDS No. Issued: Supersedes: Date: Prepared by: Approved by: European Contact: CP-239 1/5/01 8/7/95 01/05/01 EH&S Department 770-496-9500 Larry Choskey, Manager, CEH&S Lanier Worldwide, Inc. Walter Fricke, Manager, Safety & Environment Im Taubental D-41468 Neuss, Germany +49-2131-387-177 Section 2: Composition / Information on Ingredients PERCENT CAS No. EXPOSURE LIMITS SOURCE Styrene acrylate copolymer 90 27136-15-8 Not listed N/a Carbon black 4 1333-86-4 3.5mg/m3 3.5mg/m3 OSHA PEL ACGIH TLV Polypropylene wax 4 9003-07-0 Not listed N/a Organic pigment 2 84179-66-8 Not listed N/a *PEL as the product: 15mg/m3 (total dust), 5mg/m3 (respirable dust) *TLV as the product: 10mg/m3 (total dust), 5mg/m3 (respirable dust) Section 3: Hazards Identification Hazard Rating: FIRE = 0 HEALTH = 0 REACTIVITY = 0 SPECIAL = none Health Hazards (Acute, Chronic, Immediate and Potential): Minimum irritation to respiratory tract may occur as with exposure to any non-toxic dust. May cause gasping if inhaled. Inhalation should be avoided. May cause temporary eye discomfort. Health Hazards of Long Term exposure (Chronic): A manufacturer sponsored chronic inhalation study in rats using a special test toner revealed there were no lung changes at all in the lowest exposure level (1mg/m3), the most relevant level to potential human exposures. A very slight degree of fibrosis was noted in 25% of the animals at the middle exposure level (4mg/m3), while a slight degree of fibrosis was observed at the highest exposure level (16mg/m3) in all animals. These findings are attributed to “Lung Overloading”, a generic response to excessive amount of any dust retained in the lungs for a prolonged interval. The special test toner was ten times more respirable than commercially available toner to comply with EPA testing protocol and would not function properly in Xerographic equipment. Section 4: First Aid Measures Inhalation: Remove to fresh air if effects occur. Consult Eye Contact: In case of contact, immediately flush eyes with local medical personnel water for 5 minutes. Skin Contact: Wash with soap and water. Ingestion: Rinse mouth with water. Call a physician. 1 MATERIAL SAFETY DATA SHEET Page 2 of CP-239 Section 5: Fire Fighting Measures Suitable extinguishing media: CO2, dry chemical, foam or water. Extinguishing media which may not be used for safety reasons: none This material will burn in case of fire. The decomposition products are CO, CO2, and Nox. Avoid inhalation of smoke. Special protective equipment for fire fighters: none UEL: n/a LEL: n/a Section 6: Accidental Release Measures Sweep up or clean up with an approved toner vacuum. Section 7: Handling and Storage Special Handling: none Special Storage: No special storage requirements for safety reasons. Store in a cool dry place. Section 8: Exposure Control and Personal Protection Information: Respiratory Protection: none required under normal use. Hand Protection: none required under normal use. Eye Protection: none required under normal use. Skin Protection: none required under normal use. Section 9: Physical and Chemical Properties CHARACTERISTICS: Appearance: Black Melting point: N/a Form: Fine powder Vapor pressure: n/a Odor: Practically odorless Vapor density: n/a Solubility in Water: Negligible Evaporation rate: n/a Specific gravity: 1.1 Boiling point: n/a Section 10: Stability and Reactivity Conditions to avoid: none Materials to avoid: none Stability: Stable Hazardous decomposition products: CO, CO2, and NOx when burned. Section 11: Toxicological Information: Acute oral toxicity (rat) LDLO: Over 5.0 g/kg Ames Test result: Negative Carcinogenicity: In 1996, the IARC reevaluated carbon black as a GROUP 2B carcinogen (possible human carcinogen). This evaluation is given to carbon black for which there is inadequate human evidence, but sufficient animal evidence. The latter is based upon the development of lung tumors in rats receiving chronic inhalation exposures to free carbon black at a level that induce particle overload of the lungs. Studies performed in mice have not demonstrated an association between carbon black and lung tumors. Moreover, a two-year cancer bioassay using a typical toner preparation containing carbon black demonstrated no association between toner and tumor development in rats. Section 12: Environmental / Ecological Information None Section 13: Disposal Consideration Waste material may be dumped or incinerated under conditions, which meet all federal, state and local environmental regulations. Section 14: Transportation Information None Section 15: Regulatory Information None Section 16: Miscellaneous Information Information on this data sheet represents our cur...


Comentarios



Tu reseña
Tu nombre:
Introduzca dos números de la imagen:
capcha





Categoría