Iniciar sesión:
Votos - 2, Puntuación media: 5 ( )

Manual de usuario KitchenAid, modelo 4KUIS185S

Fabricar: KitchenAid
Tamaño del archivo: 438.25 kb
Nombre del archivo: 2229fef8-b3a5-4df8-b7d4-0c3289d18d06.pdf
Idioma del manual:en
Enlace gratuito para este manual disponible en la parte inferior de la página



Resumen del manual


Cut it to the same size as the production metal panel. See Figure 1. To change the bin door panel: 1. Open the bin door. 2. Remove the two screws on top of the door which hold the handle. 3. Remove the handle. 4. Slide the metal panels out. 5. Break off the ribs on the door insulation to allow for the wood thickness. See Figure 2. 6. Slide the wood panel into the door frame. 7. Replace handle and screws. To change the lower panel: 1. Remove the two screws at the bottom that hold the lower panel assembly to the ice maker. 2. Remove the two screws on the top of the panel assembly. 3. Slide the metal panels and spacers out. 4. Slide the wood panel into the door frame. 5. Replace the top of the panel assembly. NOTE: Make sure the galvanized panel is replaced in back of the panel assembly. DOOR LOWER BIN PANEL WOOD 11’Y.” ll’y,e” PANEL (285 mm) (303 mm) DIMENSIONS c I- (43 mm) - A FIGURE 1 REMOVE ALL DOOR INSULATION RIBS TO ACCEPT WOOD PANEL THICKNESS FIGURE 2 THERMOSTAT CALIBRATIONS If ice maker is installed above two thousand feet of altitude, the bin and evaporator thermostats must be adjusted to a warmer setting. Disconnect electricity, remove thermostat and follow the directions for turning the altitude adjustment screw as shown in the label on each thermostat. SHIPBOARD OPERATION When this ice cube maker is installed aboard a ship, it will be necessary to purchase and install a water deflector. This deflector hangs between the lower edge of the evaporator and the cutter grid. It keeps the water flowing over the evaporator from spilling into the storage bin area. Order the necessary parts from your local ice maker dealer. GENERAL INFORMATION . UNPACK INTERIOR PACKING OPEN BOTTOM FLAPS FIGURE 3 FIGURE 4 1 Lay carton on rear face and break open bottom flaps. 2 Set carton upright with all four flaps outward. See Figure 3. 3 Lift carton up and off of machine. 4 Remove all tape and packaging material from the outside and inside of the cabinet. See Figure 4. 5 Remove the front grill; take out the screws securing the grill at the bottom and lift it free of cabinet 6 Turn the fan by hand to make certain it moves freely 7 Loosen thumb screws holding cutter grid and water pan to “thumb tight” . UTILITIES ELECTRICITY OBSERVE LOCAL CODES Each installation is unique but will require: 1 A cold water inlet of 114” (6 mm) OD soft copper tubing and a shut-off valve. 2 Either a gravity drain system or a sump pump to lift the water to an existing drain. 3 An electrical branch circuit of 115 Volt, 60 Hz, 1 phase, with a 15 Amp delayed action fuse or circuit breaker. l LOCATE UNIT THIS UNIT MUST BE (32.2%) INSTALLED IN AN 90° F 1 BEST AREA PROTECTED FROM \ RANGE THE ELEMENTS, SUCH (21.1%) AS WIND, RAIN, WATER 70°F SPRAY OR DRIP. H CR 66 A 1 Place unit so the front side will be completely unobstructed to provide proper air flow. 2 Area should be well ventilated with temperature above 55’JF, 12.6% and below llOOF, 43.4OC. Best results are obtained between 7OOF, 21 .lOC and gOOF, 32.2OC. 3 Provision for electricity, water and drain connections should be determined. 4 Tne uni? may be closed in on the iop and three sides, bu? the front MUST BE unobstructed for air circula- rion and proper operation. Installation shoti~d be such that the cabinet can be moved iorward foi :sr- vicing, if necesczry. . LEVEL UMZT 1 After placing unit in position, check to make certain the unit is level side to side and front to back. 2 Accurate leveling is essential for proper operation. 3 Unit should be shimmed so that it is solid as well as level. The shims should be of hard permanen? type material such as masonite. 4 Compliance with National Sanitation Foundation standards require that this type of product be sealed to the floor at the bottom rail in order to prevent contamination from spills or the entrance of vermin. Therefore, we recommend that when in- stalling this product you seal it to the floor in accor- dance with those standards. A silicone-type sealer is recommended. FOR THE PLUMBER . CONNECT TO WATER . CONDENSATE PUMP (observe local codes) 1 Use l/4” (6 mm) OD soft copper tubing for the cold water supply. 2 Provide a convenient manual shut-off valve in the water line. 1 2 When drain connection below the level of the unit is not available a condensate pump may be used to lift the water to an available drain. Install condensate pump on floor behind ice maker with discharge tube to the rear. Run drain bin directly into pump as shown in Figure 5A. 3 Position the t ub’rng so it can enter the access located in the right-hand rear of the cabinet. tubing should extend beyond the cabinet when the cabinet is pushed back into position. Figure 5. hole The front See 3 4 5 Run power cord through hole into unit compartment. (See Figure 5A) Remove lower grille assembly. (See Figure 58) Remove shunt from receptable and plug in conden- sate pump. (See Figure 5C) NOTE: Always purge the water line before connection to the inlet of the water possible water val...


Comentarios



Tu reseña
Tu nombre:
Introduzca dos números de la imagen:
capcha





Categoría