|
Resumen del manual
8. Close sump drain by moving handle all of the way forward until it stops. See Figure 8. 9. Reinstall perforated water baffle/false bottom in correct position. 10.Follow normal operation instructions. 9 Form No. FR2M-0604 MAINTENANCE WEEKLY (See Figure 8) 1. Turn power switch to the OFF position. 2. Drain holding vessel to discharge visible water and debris. 3. Wipe visible deposits from the sink or tank. 4. Remove clean-out caps (2- or 3-element units only). 5. Inspect for lime and sediment build-up at the sump drain outlet and heating element chamber outlets (2 or 3 element units only have heating element chamber outlets). 6. Remove any visible lime sediment or debris deposits from the outlets using the cleaning brush supplied with the unit, Hatco part number 03.40.060.00. To remove, insert brush into the clean-out and sump drain outlets and use a scrubbing motion until clean. 7. Remove brush and flush clean water through the chambers until discharge is clear. 8. Reinstall clean-out caps removed in step 4. 9. Close all drains and fill with water before restarting. DELIMING INSTRUCTIONS CAUTION Inspect weekly for lime buildup inside unit. Excessive amounts can affect unit performance and reduce the operating life of the unit. NOTE: Product failure caused by liming or sediment buildup is not covered under warranty. CAUTION To avoid any damage to the heater unit use only delimers that are non-corrosive to aluminum, brass and stainless steel. Damage caused by corrosive material or solutions is not covered under warranty. The amount of lime and mineral content in the water and how often the unit is operated will dictate how often the unit needs to be delimed. Units supplied with water that contains high lime and mineral content may require deliming on a daily basis. NOTE: The delimer used should be a safe, non-toxic, non-corrosive solution. Follow the delimer’s instructions. In order to dissolve water scale, lime and rust deposits from the heating chamber, thermostat probes and interior surfaces of the unit, perform the following procedure: 1. Disconnect power supply to heater at breaker and turn power switch to OFF position. 2. Connect one end of a drain hose onto the sump drain outlet with the other end in a bucket or open site drain in a manner according to local plumbing codes. 3. Open sump drain valve and drain all water. 4. When draining is finished, close sump drain valve. 5. Slowly add delimer and water mixture into heat tank through sink strainer assemblies. Allow the unit to stand with the mixture in the reservoir for the recommended period of time. NOTE: The time required will vary depending on the solution used and amount of deposits in the reservoir. Form No. FR2M-0604 10 MAINTENANCE 6. After cleaning, drain all expended solution from the unit through the sump drain. 7. Thoroughly wash heater tank with fresh water for several minutes until discharge is clear and all deliming solution has been removed and rinsed. 8. Close sump drain by moving handle all of the way forward until it stops. 9. Follow normal operation instructions. CAUTION Do not turn the electrical current to the unit on until the holding vessel has been filledwith water or element burnout may occur. WARNING If service is required on this unit, contact your Authorized Hatco Service Agent, or contact the Hatco Service Department at 800-558-0607 or 414-671-6350; fax 800-690-2966 or international fax 414-671-3976. WARNING This product has no “user” serviceable parts. To avoid damage to the unit or injury to personnel, use only Authorized HatcoService Agents and Genuine Hatco Parts when service is required. WARNING Genuine Hatco Replacement Parts are specified to operate safely in the environments in which they are used. Some aftermarket or generic replacement parts do not have the characteristics that will allow them to operate safely in Hatco equipment. Itis essential to use Hatco Replacement Partswhen repairing Hatco equipment. Failure to use Hatco Replacement Parts may subjectoperators of the equipment to hazardouselectrical voltage, resulting in electrical shock or burn. 11 Form No. FR2M-0604 HATCO LIMITED WARRANTY 1. PRODUCT WARRANTY Hatco warrants the products that it manufactures (the “Products”) to be free from defects in materials and workmanship, under normal use and service, for a period of one (1) year from the date of purchase when installed and maintained in accordance with Hatco’s written instructions or 18 months from the date of shipment from Hatco. Buyer must establish the product’s purchase date by returning Hatco’s Warranty Registration Card or by other means satisfactory to Hatco in its sole discretion. Hatco warrants the following Product components to be free from defects in materials and workmanship from the date of purchase (subject to the foregoing conditions) for the period(s) of time and on the conditions listed below: a) One (1) Year Parts and Labor PLUS One (1) Additional Year Parts-Only Warranty: Toaster E...
Otros modelos de este manual:Otros aparatos de cocina - FR2 Series (571.58 kb)
Otros aparatos de cocina - FR2 Series (571.58 kb)