Iniciar sesión:
Votos - 3, Puntuación media: 3.3 ( )

Manual de usuario GE Monogram, modelo ZKD910

Fabricar: GE Monogram
Tamaño del archivo: 93.47 kb
Nombre del archivo: 1678f77f-423e-4c32-876a-8914b73e4f9c.pdf
Idioma del manual:en
Enlace gratuito para este manual disponible en la parte inferior de la página



Otros manuales para este modelo:

Resumen del manual


• Wood screws and adhesive or other hardware for installing Tools and runners or shelf to support warmer drawer. Materials • 2 x 4 or 2 x 2 lumber for runners • 2 x 4 or 2 x 2 wood block for anti-tip security Required • Saw • Level • Drill and 1/16” bit • Phillips screwdriver Runners must be level, rigidly mounted and capable of supporting 150 pounds. Product Dimensions JXPN2 – Warming drawer pan kit. This kit includes supports and one full size and one half size pan with lids. The pans fit 27" and 30" wide models. Design Information Warming Drawer Advance Planning • The drawer may be installed below a countertop, a cooktop, a single or double oven and side by side using 2 drawers. • The warming drawer can be installed below approved cooktops. Allow 2" min. clearance from bottom of cooktop burner box to top of warming drawer cutout. See page 5. • The warming drawer can be installed below approved ovens. Allow a 2" min. clearance between cutouts. Additional clearances may be required. See page 6. • Electrical power cord is located on the right side of the warming oven. Locate the outlet within reach of the 56" long power cord in an adjacent cabinet, within 42" of the right side or 16" from the left side of the cutout. A recessed receptacle can be installed on the right side of the cutout, 7" max. from the rear of cabinet. Grounding the Appliance IMPORTANT – (Please read carefully) FOR PERSONAL SAFETY, THIS APPLIANCE MUST BE PROPERLY GROUNDED. Do not use an extension cord or adapter plug with this appliance. Follow National electrical codes or prevailing local codes and ordinances. This warming drawer must be supplied with 120V, 60Hz, and connected to an individual, properly grounded branch circuit, and protected by a 15 or 20 amp circuit breaker or time delay fuse. • A properly grounded 3-prong receptacle should be located within reach of the drawers’ 56" long power cord. • Locate the receptacle in an adjacent cabinet. – within 42" of the right side or, – within 16" of the left side or, – A recessed receptacle may be located on the right side of the cutout, 7" from the back of the cabinet. In this location, the excess power cord should be coiled and taped to the right side of the unit. • When two warming drawers are installed side to side, they can operate from the same receptacle. Recessed Receptacle 7" Max. From Rear on Right Side. Drill 1-1/2" Hole For Power Cord For Left or Right Side Outlet Location IMPORTANT – (Please read carefully) The power cord of this appliance is equipped with a 3-prong (grounding) plug that mates with a standard 3-prong grounding wall receptacle to minimize the possibility of electric shock. The customer should have the wall receptacle and circuit checked by a qualified electrician to make sure the receptacle is properly grounded and has the correct polarity. • Where a standard 2-prong wall receptacle is encountered, it is the personal responsibility and obligation of the customer to have it replaced with a properly grounded 3-prong wall receptacle. Do not, under any circumstances, cut or remove the third (ground) prong from the power cord. DO NOT USE AN EXTENSION CORD. Remove Packaging and Parts Installation Below a Countertop • Place carton on a flat surface. • Open one end of the carton and lift off the top piece. • Lift the warmer up and out of the carton. • Place the drawer on top of the shipping carton to protect the drawer front and the finished flooring. Install Electrical Outlet 42" Max. 2x4 or 2x2 From Right Side. Anti-Tip Block Installation Preparation Warming Drawer • Remove all packing materials and tape. • Locate package containing 4 wood screws and set aside. Parts provided: • 4 Wood Screws Dim. A ZTD910 28-1/2” ZKD910 25-1/2” *NOTE: When installing the warming drawer below a cooktop, a solid barrier must be installed at least 1" from the lowest point of the bottom of cooktop burner box to the top of cutout. Use any solid material such as 1/4" thick plywood. Allow at least 1/4" air gap between the barrier and the top of the warming drawer. See label on top of the warming drawer for approved cooktop models. Electrical Outlet 16" Max. From Left Side. Installation Below a Drawer 23-1/2" Min. Solid Barrier 1/4" Air Gap 25" 1-1/2" Cabinet Top 36" Countertop Height 1" Min.* A 9-1/4" Install a Solid Barrier Below a Cooktop See Note Flush With Side of Cabinet 7" Max. 9" Against Rear Cabinet Wall 9" From Floor to Bottom of Block 7" Install a Solid Barrier and a 1/4" Air Gap Above Warming Drawer Electrical Outlet • When installed, the front face of the drawer will be nearly flush with adjacent cabinetry doors. • Drawer overlaps will conceal cut edges on all sides of the opening. The rough opening for the drawer must be: – Depth: 23-1/2" min. from inside back to front of cabinet frame. – Width: 25-1/2" for 27" wide models, 28-1/2" for 30" wide models. – Height: 9-1/4". • 5" min. above floor or 1" above toekick. 23-1/4" from floor to bottom of cutout is recommended for under ...

Otros modelos de este manual:
Otros aparatos de cocina - ZTD910 (93.47 kb)

Comentarios



Tu reseña
Tu nombre:
Introduzca dos números de la imagen:
capcha





Categoría