|
Resumen del manual
Follow the gas supplier's instructions • if you cannot reach you gas supplier, call the fire department. 4. Never install the fireplace • in a recreational vehicle • where curtains, furniture, clothing or other flammable objects are less than 42" from the front, top or sides of the fireplace • in high traffic areas • in windy or drafty areas 5. This fireplace reaches high temperatures. Keep children and adults away from hot surfaces to avoid burns or clothing ignition. Fireplace will remain hot for a time after shutdown. Allow surfaces to cool before touching. 6. Carefully supervise young children when they are in the room with fireplace. 7. A hearth extension is not required with this appliance. If one is installed, it is for aesthetic purposes only and does not have to meet the standard requirements. 8. Turn fireplace off and let cool before servicing or repairing. Only a qualified service person should install, service or repair this fireplace. Have fireplace inspected annually by a qualified service person. 9. You must keep control compartments, burners and circulating air passages clean. More frequent cleaning may be needed due to excessive lint and dust from carpeting, bedding material, etc. Turn off the gas valve and pilot light before cleaning fireplace. 10. Have venting system inspected annually by a qualified service person. If needed, have venting system cleaned or repaired. See Cleaning and Maintenance, page 14. 11. Keep the area around your fireplace clear of combustible materials, gasoline and other flammable vapor and liquids. Do not run fireplace where these are used or stored. Do not place items such as clothing or decorations on or around fireplace. 12. Do not use this fireplace to cook food or burn paper or other objects. 13. Do not use any solid fuels (wood, coal, paper, cardboard, etc.) in this fireplace. Use only the gas type indicated on fireplace nameplate. 14. This appliance, when installed, must be electrically grounded in accordance with local codes or, in the absence of local codes, with the National Electrical Code, ANSI/NFPA 70 or the Canadian Electrical Code, CSA C22.1. 15. Do not obstruct the flow of combustion and ventilation air in any way. Provide adequate clearances around air openings into the combustion chamber along with adequate accessibility clearance for servicing and proper operation. 16. Do not install fireplace directly on carpeting, vinyl tile or any combustible material other than wood. The fireplace must set on a metal or wood panel extending the full width and depth of the fireplace. 17. Do not use fireplace if any part has been exposed to or under water. Immediately call a qualified service person to arrange for replacement of the unit. 18. Do not operate fireplace if any log is broken. 19. Do not use a blower insert, heat exchanger insert or other accessory not approved for use with this fireplace. 20. Provide adequate clearances around air openings. Dimensions Safety information Continued SIDE VIEWFRONT VIEWTOP VIEW4 1/2" 12" 2 1/2" 24"40" 36 1/2" 8" 37 1/2" 3 1/4" 40" 9 1/2" 2 1/2" 24" BACK VIEW16"12" 5 1/4" 5 1/2"9" 13" 2 1/2" 20 1/2" 23" 19 1/4" 19 3/8"20 5/8" 6" 24" 19 1/4"4" 6" O.D. 16" 52 1/2" Figure 1 - Fireplace Dimensions Introduction Models (V)GL36CR(P)/CL(P) are decorative gas fireplaces that use a millivolt gas control valve with millivolt ignition system. Models (V)GL36CR(P)E/CL(P)E use an electronic gas control valve with electronic ignition system. These systems require a 6" B-type vent that is not supplied by DESA. For installation guidelines, check your B-vent instructions. WARNING: This gas appliance must not be connected to a chimney flue servicing a solid fuel burning appliance. If you are uncertain as to what gas your unit is approved and tested for, check rating plate on inside of fireplace opening or consult your local distributor of DESA products. BEFORE YOU BEGIN Before beginning the installation of your appliance, read these instructions through completely. This DESA appliance and its approved components are safe when installed according to this installation manual and are operated as recommended by DESA. Unless you use DESA approved components tested for this appliance, YOU MAY CAUSE A FIRE HAZARD! The DESA warranty will be voided by and DESA disclaims any responsibility for the following actions : A) Modification of the appliance or any of the components manufactured by DESA unless otherwise permitted by DESA. B) Use of any component part not approved by DESA in combination with this appliance. C) Installation and/or operation in a manner other than instructed in this manual. D) The burning of anything other than the type of gas approved for use in this gas appliance. This appliance, when installed, must be electrically grounded in accordance with local codes or, in the absence of local codes, with the National Electrical Code, ANSI/NFPA 70-1987 and the CSA C22.1 Canadian Electrical Code for Canada. The installation must conform...
Otros modelos de este manual:Otros accesorios para la casa - GL36CLP (1.28 mb)
Otros accesorios para la casa - GL36CR (1.28 mb)
Otros accesorios para la casa - GL36CRP (1.28 mb)