|
Resumen del manual
Choosing Single Action Programs 1. Press the MODE button until the display shows .M System Setup.. 2. Press the UP button to arrive at .M Single Action.. 3. Press the SETUP button to enter menu function. 4. Press the UP and DOWN buttons to toggle built in programs. Press SETUP button to choose the presently viewed program number. 5. Upon selecting the program, the menu will immediately display whatever modifier may exist for that individual program selected. It can display .Flash Speed: 100.or .Run Speed: 100.for example. Pressing the SETUP button will toggle the various modifiers available for the program as listed in the table above. 6. Use the UP and DOWN buttons to adjust the values of modifiers accordingly. Remember that SETUP will toggle the various options while UP and DOWN changes the values. 7. Press the MENU button to retain the new settings.. 8. Press MENU again if necessary to return to the Main Menu. COLORmist System User Manual 8 2005-10-10/18:36 Operating Instructions DMX Control Mode With exception to the system setup process all control functions on the controller can be accessed and executed externally via a Universal DMX controller. First you must connect the LED-CHVA controller to an existing DMX daisy chain. The controller is addressable just like any other DMX device or fixture and it will be controlled as if it were a fixture in most intelligent light consoles. Setting the DMX address 1. Press the MODE button until the display shows .M System Setup.. 2. Press the SETUP button to enter the .M System Setup.menu function. 3. The controller should display immediately .1 Dmx Ch.. Press the SETUP button to select function. 4. Use the UP and DOWN buttons to increase or decrease the channel values. This value represents the starting address for this device. The controller occupies 4 channels of DMX 5. The unit will now respond to DMX command. Do not press any other buttons other than to change the channel values. The next step may require you to create a device profile within your lighting controller. Proceed to section .DMX Channel Values.for a detailed chart of the control values for each channel of DMX. Running in DMX Mode If the control panel menu displays .1 Dmx Ch.press SETUP to activate DMX control mode. For instructions on arriving at this menu item repeat the instructions .Setting the DMX address.located directly above this subject. Daisy Chain Connection 1. Connect the (male) 3 pin connector side of the DMX cable to the output (female) 3 pin connector of the first fixture. 2. Connect the end of the cable coming from the first fixture which will have a (female) 3 pin connector to the input connector of the next fixture consisting of a (male) 3 pin connector. Then, proceed to connect from the output as stated above to the input of the following fixture and so on. System Configuration & Connection COLORmist DMX Daisy Chain From Controller COLORmist Controller COLORmist Power Unit DMX line DMX line Power-Signal Cable Please read the Appendix Section .MIST-PS8 Power Unit Configurations., for a detailed description and illustration of the maximum length and load capacity of the power unit. COLORmist Panel COLORmist System User Manual 9 2005-10-10/18:36 APPENDIX E DMX Primer There are 512 channels in a DMX-512 connection. Channels may be assigned in any manner. A fixture capable of receiving DMX-512 will require one or a number of sequential channels. The user must assign a starting address on the fixture that indicates the first channel reserved in the controller. There are many different types of DMX controllable fixtures and they all may vary in the total number of channels required. Choosing a start address should be planned in advance. Channels should never overlap. If they do, this will result in erratic operation of the fixtures whose starting address is set incorrectly. You can however, control multiple fixtures of the same type using the same starting address as long as the intended result is that of unison movement or operation. In other words, the fixtures will be slaved together and all respond exactly the same. DMX fixtures are designed to receive data through a serial Daisy Chain. A Daisy Chain connection is where the DATA OUT of one fixture connects to the DATA IN of the next fixture. The order in which the fixtures are connected is not important and has no effect on how a controller communicates to each fixture. Use an order that provides for the easiest and most direct cabling. Connect fixtures using shielded two conductor twisted pair cable with three pin XLR male to female connectors. The shield connection is pin 1, while pin 2 is Data Negative (S-) and pin 3 is Data positive (S+). CHAUVET carries 3-pin XLR DMX compliant cables, DMX-10 (33.), DMX-4.5 (15.) and DMX-1.5 (5.) COMMON DMX + DMX INPUT OUTPUT 1 3 2 1 3 2 1 3 2 Resistance 120 ohm 1/4w between pin 2 (DMX -) and pin 3 (DMX +) of the last fixture. Termination reduces signal errors and to avoid signal transmission p...
Otros modelos de este manual:Otros accesorios para la casa - COLORMIST MIST-PANEL (419.93 kb)
Otros accesorios para la casa - COLORMIST MIST-PAR80 (419.93 kb)
Otros accesorios para la casa - COLORMIST MIST-PS8 (419.93 kb)