Resumen del manual
Flip the light switch off for one second then back on to toggle between AUTO and MANUAL MODE. Manual mode works only with the ON-TIME switch in the 1, 5, or 10 position. 240-026-A © 2008 Atlas Lighting Products, Inc. 598-1092-02 Mode Switching Summary TEST Move ON-TIME Switch to 1, 5, or 10 minutes AUTO Flip light switch off for one second then back on* MANUAL MODE * If you get confused while switching modes, turn the power off for one minute, then back on. After the calibration time the control will be in the AUTO mode. INSTALLATION For easy installation, select an existing light with a wall switch for replacement. For best performance, mount the fixture about 8 ft.(2.4 m) above the ground.NOTE: If fixture is mounted higher than 8 ft.(2.4 m), aiming the sensor down will reduce coverage distance. Wall Mount Eave Mount For under eave installation, the sensor head must be rotated as shown in the next two steps for proper operation and to avoid the risk of electrical shock. For eave mount only: .Swing the sensor head towards the clamp screw joint. If the sensor pops out of the ball joint, loosen the clamp screw and push the sensor back into the ball joint. Tighten the clamp screw when done. .Then rotate the sensor head clockwise 180° so the controls face down. Controls Controls Controls Clamp Screw 2 598-1092-02 Wire the Light Control WARNING: Turn power off at circuit breaker or fuse. . Remove the existing light fixture. . Installthemountingstrapasshownusingtwoscrews that fit your junction box. . The plastic hanger can be used to hold the fixture while wiring. The small end of the plastic hanger can be threaded through the hole in the center of the cover plate. The small end then goes into one of the slots on the mounting strap. . Route the light control’s wires through the large gasket holes. . Twistthejunctionboxwiresandfixturewirestogether as shown. Secure with wire connectors. White to White Black to Black Junction box ground wire to green ground screw on fixture. Gasket Mounting Strap Mounting Bolt Rubber Plug Mount the Light Control . Align the light control cover plate and cover plate gasket. Secure with the mounting bolt. . Push the rubber plug firmly into place. . If a wet location junction box was not used, caulk the wall plate mounting surface with silicone weather sealant. To avoid water damage and electrical shock, keep bulb holders 30° below horizontal. Keep bulbs at least 1" (25 mm) from the Lock Nut sensor.Do not allow the bulbs to block Lens the lens. . Adjustthebulbholdersbylooseningthelocknutsbut do not rotate the bulb holders more than 180° from thefactorysetting.Whenscrewinginthefloodlamps, do not overtighten. 598-1092-02 3 NOTE: Iffixtureismountedhigherthan8ft.(2.4m),aiming the sensor down will reduce coverage distance. The detector is less sensitive to motion directly towards it. TEST AND ADJUSTMENT . Turn on the circuit breaker and light switch. NOTE: Sensor has a 1 1/2 minute warm up period before it will detect motion. When first turned on, wait 1 1/2 minutes. NOTE: Meets the ENERGY STAR® guidelines when used with 120 W Max bulbs. . Turn the RANGE control to the medium position (halfway between MIN and MAX) and the ON-TIME control to the TEST position. RANGE ON-TIME 10 5 1 TEST MIN MAX Bottom of Sensor Avoid aiming the control at: • Objects that change temperature rapidly, such as heating vents and air conditioners. These heat sources could cause false triggering. • Areas where pets or traffic may trigger the control. • Nearby large, light-colored objects reflecting light may trigger the shut-off feature. Do not point other lights at the sensor. 8 ft. (2.4 m) 180° 70 ft. (21 m) Maxi...
Otros modelos de este manual:Otros accesorios para la casa - Guardian Pro 180 Series (138.41 kb)
Otros accesorios para la casa - Guardian Pro MLG180W (138.41 kb)