Iniciar sesión:
Votos - 2, Puntuación media: 4.5 ( )

Manual de usuario Martin Fireplaces, modelo BV5142

Fabricar: Martin Fireplaces
Tamaño del archivo: 1.07 mb
Nombre del archivo:
Idioma del manual:en
Enlace gratuito para este manual disponible en la parte inferior de la página



Resumen del manual


The appliance will malfunction or the valve will be damaged. CAUTION Electrical connections should only be performed by a qualified, licensed electrician. Main power must be off when connecting to main electrical power supply or performing service. All wiring shall be in compliance with all local, city, and state codes. The appliance, when installed, must be electrically grounded in accordance with local codes, or in the absence of local codes, with the National Electrical Code ANSI / NFPA 70 (latest edition), or the Canadian Electrical Code, CSA C22.1. Label all wires prior to disconnection when servicing controls. Wiring errors can cause improper and dangerous operations. Verify proper operation after servicing. Remote Wall Switch Fifteen (15) feet of 18 Ga. wire is provided as standard with this fireplace, that may be routed to a remote wall switch. The wire has been pre-wired at the valve and routed through the right side, outer shell. (Access is also available on the left side through the square hole on that side). Position the wall switch inside of a non-metallic junction box (not provided) at the desired location on the wall. Refer to Figure 13: Wiring Diagram for Standing Pilot - Millivolt System. Do not extend beyond the wall switch wire length provided. NOTE Extended lengths of wire may cause the fireplace not to function properly. Longer length of wire is permitted if the wire is a larger gauge (diameter) wire. Always check with local codes. GAS LIINE AND ELECTRIICAL IINSTALLATIION 17 Figure 13: Wiring Diagram for Standing Pilot - Millivolt System Optional DC Remote Systems These instructions supersede the section entitled “Hearth Mount” in the Millivolt hand held remote instructions supplied with the remote. NOTE Remote receiver must be mounted outside the appliance, due to high temperatures inside the chamber. This will prevent failures and longer battery life. 1. Plug in the remote connector wire to the remote receiver. 2. Mount remote control receiver at junction box (for your wall switch) 3. Connect the _” female connector to the valve TPTH and TH terminal. Millivolt Control Valve Checklist: The millivolt (thermopile) control is a self-powered combustion gas control. Refer to Figure 13: Wiring Diagram for Standing Pilot - Millivolt System. The millivolt system and individual components may be checked with a millivolt meter having 1-1000 mV range. Conduct each check listed below by connecting the meter test leads to the terminals indicated. Refer to OPERATING INSTRUCTIONS for safety and lighting instructions. Thermopile Output Check Pilot must be lit and the valve control knob turned to the “PILOT” or “ON” position. “RS-ON-OFF” switch must be in the “OFF” position. Meter leads must be connected to the TP and the TH/TP terminals on the control valve. If the meter reading is not 500-millivolt minimum, then readjust pilot for maximum millivolt output. If millivolt reading is still below minimum specified, check wire connection and then replace the thermopile. Complete Millivolt System Check Pilot must be lit and the valve control knob turned to the “ON” position. Meter leads must be connected to the TP and the TH/TP terminals on the control valve. GAS LIINE AND ELECTRIICAL IINSTALLATIION 18 • Turn RS-ON-OFF switch to the “ON” position. If meter is reading more than 175 millivolt and the main burner does not come on, then replace control valve. If meter is reading less than 175 millivolt, then refer to TROUBLESHOOTING section of this manual to determine the cause of the low reading. • Turn RS-ON-OFF switch to the “RS ” position and wall switch to “ON” If meter is reading more than 175 millivolt and the main burner does not come on, then replace control valve. If meter is reading less than 175 millivolt, then refer to TROUBLESHOOTING section of this manual to determine the cause of the low reading. Electronic Pilot Ignition Wiring: WARNING Do not connect 110-120 VAC to the Remote Wall Switch. The appliance will malfunction or be destroyed. Figure 14: Wiring Diagram for Electronic Ignition System Remote Wall Switch Position the wall switch. Refer to Figure 14: Wiring Diagram for Electronic Ignition System. Do not extend beyond the 15 feet of wire. Optional DC Remote Systems These instructions supersede the section entitled “Hearth Mount” in the Millivolt hand held remote instructions supplied with the remote. GAS LINE AND ELECTRICAL INSTALLATION GAS LINE AND ELECTRICAL INSTALLATION NOTE Remote receiver must be mounted outside the appliance, due to high temperatures inside the chamber. This will prevent failures and longer battery life. 1. Plug in the remote connector wire to the remote receiver. 2. Connect the wire terminal from the remote receiver to replace the 15’ wall switch connection to the switch as shown in the Figure 14. 3. Mount remote control receiver at junction box (for your wall switch). 19 FINAL INSTALLATION FINAL INSTALLATION FINAL INSTALLATION Wall Finishing: Definitions: Combu...

Otros modelos de este manual:
Otros accesorios para la casa - BV4536 (1.07 mb)

Comentarios



Tu reseña
Tu nombre:
Introduzca dos números de la imagen:
capcha





Categoría