Resumen del manual


Diagnostic Messages Message Meaning Action Required No message on display 1) Spa temperature is unknown. 1) After pump has been running for 2 minutes temperature will be displayed. 2) Spa is in Economy or Sleep mode. 2) In Economy or Sleep mode, the pump may be off for hours outside a filter cycle. If you wish to see the current spa temperature, either switch to Standard mode or turn Jets1 on for at least two minutes. 3) Power has been cut off to the spa. 3) The control panel will be disabled until power returns. Spa settings and time of day will be preserved for 30 days with a battery back-up. dr Insufficient water detected in heater. Spa will be shut down for 15 minutes. Check water level in spa. Refill if necessary. Make sure pumps are been primed and filter cartridges are clean. Press any button to reset or wait 15 minutes and spa will automatically reset. If message spa does not reset, call your dealer or service organization. drY Insufficient water detected in heater. Spa is shut down. (Displays on third occurrence of dr message.) Follow directions for dr message and press any button to reset spa. Spa will not automatically reset when dry or dY is displayed. Ec Indicates heater is in Economy Mode. None. -- Temperature unknown After the pump has been running for two minutes, the temperature will be displayed. HFL A difference in readings between temperature sensors has been detected indicating a possible water flow problem. Make sure spa is filled to proper level and that pumps are primed and filter cartridges are clean. If message does not reset, call your dealer or service organization. ICE Potential freeze condition detected. No action required. The pumps and the blower will automatically activate regardless of spa status. LF Persistent low flow problems. Heater is shut down, but other spa functions continue to run normally. Displays on the fifth occurrence of the HL or HFL message within 24 hours. Follow action required for HL or HFL message. Heating capacity of the spa will not reset automatically. Press any button to reset. OHS Overheat protection. The spa has shut down. One of the sensors has detected that the spa water is 110°F. DO NOT ENTER THE WATER. Remove the spa cover and allow water to cool. At 107°F, the spa should automatically reset. If spa does not reset, shut off the power to the spa and call your dealer or service organization. Message Meaning Action Required OHH Overheat protection (spa is shutdown). One sensor has detected 118.F (48.C) at the heater. DO NOT ENTER THE WATER! Remove the spa cover and allow spa to cool below 107.F (42.C). Press any button on the topside display to reset spa. If spa will not reset after spa has cooled, turn off power for approximately 30 seconds and then turn power back on. If display message is repeated then shut the power off to the spa and call your dealer or service organization. Pr When your spa is first actuated, it will go into priming mode. The priming mode will last for up to four minutes and then the spa will begin to heat and maintain the water temperature in the Standard mode. SL Indicates heater is in Sleep Mode. None. SnA Snb Spa is shut down. The sensor that is plugged into the sensor “A” or “B” jack is not working. If the problem persists, contact your dealer or service organization. (May appear temporarily in an overheat situation and disappear when the heater cools.) SnS Sensors are out of balance. If this is alternating with the • temperature, it may just be a temporary condition. If the display shows only this • message (periodically blinking), the spa is shut down. Contact your dealer or service organization. ST Indicates heater is in Standard Mode. None. Jets Almost all of the jets in your spa are adjustable. Rotating the face of an adjustable jet to the left (counter-clockwise) will decrease the amount of water flow through the jet. Rotating the face of an adjustable jet to the right (clockwise) will increase the amount of water flow through the jet. (See example shown below.) Neck jets adjust in the opposite directions (counter- clockwise to increase, clockwise to decrease). LED Light Operation Press the LIGHT button on the topside control panel to turn the spa light on. If your spa has LED lights, they will also light up at the same time as the spa light. The LED lights operate in three three modes: Cycle: 1. The first time you press the LIGHT button, the lights will cycle through all the colors in this order: White Cyan Magenta Blue Yellow/green Green Red To cycle through the different color choices, press the button repeatedly. Each time you press the button, you advance to the next color. Flashing white: 2. When you have cycled through all the colors, the next time you push the LIGHT button, the LED lights will flash white. Fading cycle: 3. The next time you push the LIGHT button, the lights will gradually fade from one color to the next in the order shown above. Clear Water Plan This section is intended for new spa owners ...


Comentarios



Tu reseña
Tu nombre:
Introduzca dos números de la imagen:
capcha





Categoría