Iniciar sesión:
Votos - 4, Puntuación media: 4 ( )

Manual de usuario Cooper Lighting, modelo Galleria Round 150-1000W

Fabricar: Cooper Lighting
Tamaño del archivo: 44.22 kb
Nombre del archivo: e8d614c6-f940-4c3d-855e-9b8683de1c63.pdf
Idioma del manual:en
Enlace gratuito para este manual disponible en la parte inferior de la página



Resumen del manual


Rotatable optics standard • Formed aluminum door for arm-mount fixture has retaining springs, while spider-mount unit has a heavy-duty hinge and captive retaining screws • Flat or convex tempered glass lens • U.L. listed for wet locations. CSA certified • Approximate net weight: 86 lbs. (40 kgs.) 1164 COOPER LIGHTING DESCRIPTION DIMENSIONS The Galleria Round combines beauty and versatility to make it the optimum choice in today's energy- and design-conscious A environment. An aesthetic reveal in the roll-formed aluminum housing carries on the Galleria family look while a variety of mounting options and lamp B wattages provide maximum flexibility. EFD Fixture ABC DE F Powered by GRM 150-1000W 18 1/4" 3 1/2" 19 3/4" 24 1/2" 6" or 14" 16" [464mm] [89mm] [502mm] [676mm] [152mm] or [356mm] [406mm] GRL 1000W 19 3/4" 4 1/2" 25 5/8" 32 15/16" 6" or 14" 19 3/4" [502mm] [108mm] [651mm] [837mm] [152mm] or 356mm] [502mm] technology CD ORDERING INFORMATION SAMPLE NUMBER: GRM-AM-250-MH-120-FT-FG-DP-L Product Family GRM=Galleria Round Medium GRL=Galleria Round Large Mounting Method AM=Arm Mount 1 AIR=Arm Included for Round Pole 2 AIS=Arm Included for Square Pole 2 SM=Spider for 3" O.D. Tenon Lamp Wattage 3 150=150W 175=175W 250=250W 320=320W 4 350=350W 4 400=400W 5 1000=1000W 6 Lamp Type MH=Metal Halide Voltage 9 120=120V 208=208V 240=240V 277=277V 480=480V MT=Multi-Tap 10 TT=Triple-Tap 10 E1=Electronic 120-277V 11 E2=Electronic (See Below) Options & Accessories MP=Pulse Start Metal Halide (CWA) HPS=High Pressure Sodium MPE=ECONTM 200-277V Electronic Powered Pulse Start Metal Halide 7 Distribution Horizontal 1F=Type I Formed 12 2F=Type II Formed 3F=Type III Formed FT=Forward Throw Vertical AR=Area Round AS=Area Square 3V=Type III Vertical RW=Rectangular Wide 13 Lens Type FG=Flat Glass 14 SG=Sag Glass Colors 15 (add as suffix) BZ=Bronze AP=Grey BK=Black WH=White DP=Dark Platinum GM=Graphite Metallic MPD=ECONTM Dimmable Electronic Powered Pulse Start Metal Halide 7, 8 E.P.A. Single Medium Fixture (without arm): 1.7 / Single Large Fixture (without arm): 2.5 Spider Mount Medium: 2.0 / Spider Mount Large: 2.8 Options 16 F=Single Fuse (120, 277 or 347V) FF=Double Fused (208, 240 or 480V) EM=Quartz Restrike with Delay (Hot Restrike Only) Q=Quartz Restrike (Hot Restrike Only) R=NEMA Twistlock Photocontrol Receptacle HS=House Side Shield 17 VS=Vandal Shield 18 L=Lamp Included Accessories 19 MA1061 =House Side Shield—Medium Housing (Field Installed) MA1062 =House Side Shield—Large Housing (Field Installed) OA/RA1016=Photocontrol–Multi-Tap OA/RA1027=Photocontrol–480V OA1201=NEMA Twistlock Photocontrol—347V MA1025XX=14" Arm for Square Pole. 1.0 EPA MA1026XX=6" Arm for Square Pole. 0.5 EPA MA1027XX=14" Arm for Round Pole. 1.0 EPA MA1028XX=6" Arm for Round Pole. 0.5 EPA MA1029XX=Wall Mount Bracket with 10" Arm MA1010XX=Single-Arm Tenon Adapter for 3 1/2" O.D. Tenon MA1011XX=2 @ 180° Tenon Adapter for 3 1/2" O.D. Tenon MA1012XX=3 @ 120° Tenon Adapter for 3 1/2" O.D. Tenon MA1013XX=4 @ 90° Tenon Adapter for 3 1/2" O.D. Tenon MA1014XX=2 @ 90° Tenon Adapter for 3 1/2" O.D. Tenon MA1015XX=2 @ 120° Tenon Adapter for 3 1/2" O.D. Tenon MA1016XX=3 @ 90° Tenon Adapter for 3 1/2" O.D. Tenon MA1017XX=Single-Arm Tenon Adapter for 2 3/8" O.D. Tenon 12 MA1018XX=2 @ 180° Tenon Adapter for 2 3/8" O.D. Tenon 12 MA1019XX=3 @ 120° Tenon Adapter for 2 3/8" O.D. Tenon 12 MA1045XX=4 @ 90° Tenon Adapter for 2 3/8" O.D. Tenon 12 MA1048XX=2 @ 90° Tenon Adapter for 2 3/8" O.D. Tenon 12 MA1049XX=3 @ 90° Tenon Adapter for 2 3/8" O.D. Tenon 12 NOTES: 1 Arm not included. See Accessories. 2 Arm length varies based on housing size: 11-1/2" for GRM and 14" for GRL. 3 150W medium-base socket. 175W-1000W mogul-base. 4 Pulse Start Metal Halide only. 5 Requires reduced envelope ED-28 lamp when used with GRM housing and flat glass vertically lamped optics. 6 1000W in GRM housing requires reduced envelope BT-37 lamp. 7 Only available in 250-400W Pulse Start Metal Halide and vertical optics. Must specify E1 or E2 voltage. 8 Provides 0-10V DC low voltage, leads used in dimming control. 9 Product also available in non-US voltages and 50Hz for international markets. Consult factory for availability and ordering information. 10 Multi-Tap ballast is 120/208/240/277V wired 277V. Triple-Tap ballast is 120/277/347V wired 347V. 11 250W only. 12 Medium housing fixture only. 13 RW optic not available with flat glass. 14 1000W GRL with flat glass requires BT-37 lamp and is not available in AS, RW or 3V distributions. 15 Other finish colors available, including a full line of RAL color matches. Consult your Cooper Lighting Representative. 16 Add as suffix in the order shown. 17 House side shield available on 2F, 3F, FT and all vertically lamped distributions when combined with sag glass. 18 Arm mount only, 400W Maximum. 19 Order separately, replace XX with color suffix. 20 Specifications and dimensions subject to change without notice. ...


Comentarios



Tu reseña
Tu nombre:
Introduzca dos números de la imagen:
capcha





Categoría