Fabricar: Baxi Potterton
Tamaño del archivo: 1004.75 kb
Nombre del archivo: 888f5f02-bbde-495b-8756-bfce6bd17d13.pdf
|
Resumen del manual
However, if further information is required, our Baxi Fires Division Technical Helpline will be pleased to help. Telephone 08706 061 065 (National call rates apply in the United Kingdom). In the Republic of Ireland Telephone 0044 8706 061 065. This guide is intended to help you care for your Baxi Fires Division gas fire. Please read thoroughly before using and keep for future reference. INSTALLER: Please leave this guide with the owner © Baxi Heating U.K. Limited 2007. OWNER GUIDE OWNER GUIDE THIS APPLIANCE IS FOR USE WITH NATURAL GAS (G20). THIS APPLIANCE IS SUITABLE ONLY FOR INSTALLATION IN THE UNITED KINGDOM (GB) AND THE REPUBLIC OF IRELAND (IE). © Baxi Heating U.K. Limited 2007. All rights reserved. No part of this publication may be reproduced in any material form (including photocopying), stored in any medium by electronic means (including in any retrieval system or database) or transmitted, in any form or by any means, whether electronic, mechanical, recording or otherwise, without the prior written permission of the copyright owner. Applications for the copyright owner's permission to reproduce any part of this publication should be made, giving details of the proposed use, to the following address: The Company Secretary, Baxi Heating UK Limited, Pentagon House, Sir Frank Whittle Road, Derby, DE21 4XA. Warning: Any person who does any unauthorised act in relation to a copyright work may be liable to criminal prosecution and civil claims for damages. Baxi Fires Division, Erdington, Birmingham B24 9QP Because our policy is one of constant development and improvement, details may vary slightly from those given in this publication © Baxi Heating U.K. Limited 2007. Page 2 OWNER GUIDE OWNER GUIDE Safety First. Baxi Fires Division fires are CE Approved and designed to meet the appropriate British Standards and Safety Marks. Quality and Excellence. All Baxi Fires Division fires are manufactured to the highest standards of quality and excellence and are manufactured under a BS EN ISO 9001 quality system accepted by the British Standards Institute. The Highest Standards Baxi Fires Division is a member of the Society of British Gas Industries which works to ensure high standards of safety, quality and performance. Careful Installation Baxi Fires Division is a CORGI registered company. All our gas fires must be installed by a competent CORGI Registered Installer in accordance with our Installer Guide and should not be fitted directly on to a carpet or floor of combustible material. © Baxi Heating U.K. Limited 2007. Page 3 LIST OF CONTENTS OWNER GUIDE LIST OF CONTENTS OWNER GUIDE Section Page SAFETY 4 APPLIANCE DIMENSIONS 6 GAS CONSUMPTION 6 OPERATING YOUR FIRE 7 CLEANING YOUR FIRE 9 MAINTENANCE 10 USEFUL TELEPHONE NUMBERS 11 This gas fire is designed to meet the most stringent quality, performance and safety requirements to provide you with many years’ trouble-free service. This guide aims to improve your understanding and appreciation of your gas fire by providing simple and informative instructions to ensure that you benefit from the excellent performance and features it has to offer. SAFETY IF YOU SMELL GAS ! DON’T SMOKE. ! EXTINGUISH ALL NAKED FLAMES. ! DON’T TURN ELECTRICAL SWITCHES ON OR OFF. ! TURN OFF THE GAS SUPPLY AT THE METER. ! OPEN DOORS AND WINDOWS TO GET RID OF THE GAS. ! IMMEDIATELY CALL THE GAS EMERGENCY SERVICE FROM A NEIGHBOURS PHONE - SEE YOUR LOCAL TELEPHONE DIRECTORY. Do have the fire installed by a competent person. In the United Kingdom, installation must be in accordance with the latest edition of the Gas Safety (installation & use) Regulations. In the Republic of Ireland, installation must be in accordance with all national and local regulations in force. Do have the chimney swept prior to installation if it was previously used for solid fuel. Do have the fire installed in accordance with the installer guide. Do provide a suitable guard that complies with BS 8423 for the protection of young children, the elderly and the infirm. Such a guard is also recommended for the protection of pet animals. (Although this fire conforms to all the applicable standards, it is a heating appliance and certain parts of its surface will become hot). Note: The glass panel supplied with the fire acts as a fireguard conforming to BS1945:1971 and satisfies the Heating Appliance (Fireguard) (Safety) Regulations1991. © Baxi Heating U.K. Limited 2007. Page 4 OWNER GUIDE OWNER GUIDE Do wait three minutes before attempting to relight if the fire is switched off or the flames are extinguished for any reason. (Your fire is fitted with a safety device that will automatically shut off the gas supply to the fire if, for any reason, the flames go out). Do get advice about the suitability of any wall covering near your fire. Soft wall coverings (e.g. embossed vinyl, etc.) which have a raised pattern are easily affected by heat. They may, therefore, scorch or become discoloured when close to a he...