Iniciar sesión:
Votos - 1, Puntuación media: 4 ( )

Manual de usuario Elation Professional, modelo Indoor Furnishings

Fabricar: Elation Professional
Tamaño del archivo: 211.16 kb
Nombre del archivo: waterfall.pdf
Idioma del manual:en
Enlace gratuito para este manual disponible en la parte inferior de la página



Resumen del manual


Service Hours are Monday through Friday 9:00 a.m. to 5:00 p.m. Pacific Standard Time. Voice: (800) 322-6337 Fax: (323) 582-2610 E-mail: support@elationlighting.com Warning! To prevent or reduce the risk of electrical shock or fire, do not expose this unit to rain or moisture. Caution! There are no user serviceable parts inside this unit. Do not attempt any repairs yourself, doing so will void your manufactures warranty. In the unlikely event your unit may require service please contact your nearest Elation dealer. DISCHARGE LAMP WARNING! This fixture is fitted with a discharge lamp which is highly susceptible to damage if improperly handled. Never touch lamp with your bare fingers as the oil from your hands will shorten lamp life. Also, never move the fixture until the lamp has had ample time to cool. Remember, lamps are not covered under warranty conditions. ©Elation Lighting® - - Waterfall™ Instruction Manual Page 2 Waterfall™ Lamp Replacement Caution! Never open the unit when in use. Always disconnect the main power before attempting to replace the lamp. Remember always replace with the same type lamp and fuse. 1. Be sure to follow the proper procedures when handling discharge lamp. 2. Remove the thumb screw on the trap door located at the rear of the unit. 3. Pull down the trap door to expose the socket assembly. 4. Remove and replace the lamp. 5. Reassemble. Waterfall™ Cleaning Due to fog residue, smoke, and dust cleaning the internal and external optical lenses must be carried out periodically to optimize light output. 1. Use normal glass cleaner and a soft cloth to wipe down the outside casing. 2. Use a brush to wipe down the fan grill and remove as much built up as possible. 3. Clean the external optics with glass cleaner and a soft cloth every 20 days. 4. Clean the internal optics with glass cleaner and a soft cloth every 30-60 days. 5. Always be sure to dry all parts completely before plugging the unit in. Cleaning frequency depends on the environment in which the fixture operates (i.e. smoke, fog residue, dust, dew). Waterfall™ Warranty Card The Waterfall™ carries a two year limited warranty. We recommend you fill out the enclosed warranty card to validate your purchase. All returned service items whether under warranty or not, must be freight pre-paid and accompany a R.A. Number. If the unit is under warranty, you must provide a proof of purchase invoice. ©Elation Lighting® - - Waterfall™ Instruction Manual Page 7 Waterfall™ Dip Switch Settings MASTER - HEAD 1 HEAD 3 HEAD 2 HEAD 4 Waterfall™ DMX Traits The Waterfall™ uses one DMX channel. The chart to the right details the DMX traits. The color scroll option will increase in speed as the DMX value progresses from 144 to 255. 144-255 Color Scroll 135-143 Half Pink 12b -13 4 Pink 117-125 Orng/Pink IDA - lib Orange TT-1D7 Yell/Orng TD-Tfl Yellow Ö1-ÖT Grn/Yellow 72-flD Green b3 - 71 Blue/Grn 5 4 - b2 Blue 45-53 Red/Blue 3b - 44 Red ru i uu Ln White/Red Ifl - 2b White □ T-17 1/2 White Blackout ©Elation Lighting® - - Waterfall™ Instruction Manual Page 6 Waterfall™ Set Up Power Supply: Before plugging your unit in be sure the source voltage in your area matches the required voltage for your Elation® Waterfall.™ The Elation® Waterfall™ is available in a 115v and 230v version. Line voltage may vary from venue to venue. Be sure to plug your unit into a matching wall outlet before attempting to operate. Data Cable (DMX Cable) Requirements (For DMX Operation Only and Master-Slave): The Waterfall can be controlled via DMX-512 protocol. The Elation® Waterfall™ is a single channel DMX unit. The DMX address is set on the rear panel of the Waterfall. Your unit and your DMX controller require a standard 3-pin XLR connector for data input and data output (Figure 1). If you are making your own cables, be sure to use standard two conductor shielded cable (This cable may be purchased at almost all pro sound and lighting stores). Your cables should be made with a male and female XLR connector on either end of the cable. Also remember that DMX cable must be daisy chained and can not be Figurel split. Notice: Be sure to follow figure three when making your own cables. Do not use the ground lug on the XLR connector. Do not connect the cable’s shield conductor to the ground lug or allow the shield conductor to come in contact with the XLR’s outer casing. Grounding the shield could cause a short circuit and erratic behavior. XLR Male Socket XLR Female Socket 1 Ground 2 Cold 2 Cold 1 Ground u"ultL 3Hot RanrP? 3 Hot Figure 2 I_______________________________________________________I XLR Pin Configuration Pin 1 = Shield Pin 2 = Data Compliment (negative) Pin 3 = Data True (positive) COMMON DMX512 OUT 3-PIN XLR Figure 3 ©Elation Lighting® - - Waterfall™ Instruction Manual Page 3 Waterfall™ Set Up Special Note:...


Comentarios



Tu reseña
Tu nombre:
Introduzca dos números de la imagen:
capcha





Categoría