Iniciar sesión:
Votos - 4, Puntuación media: 4 ( )

Manual de usuario Furuno, modelo PG-1000

Fabricar: Furuno
Tamaño del archivo: 469.94 kb
Nombre del archivo: d5ac2c43-49e8-4ace-9336-48b3dd55adde.pdf
Idioma del manual:en
Enlace gratuito para este manual disponible en la parte inferior de la página



Resumen del manual


2, 2000 All rights reserved. Printed in Japan PUB. No. OME-72460 PG-1000 (HIMA) SAFETY INSTRUCTIONS SAFETY INSTRUCTIONS Safety Information for the Installer WARNING Turn off the power at the mains switchboard before beginning the installation. Post a sign near the switch to indicate it should not be turned on while the equipment is being installed. Fire or electrical shock can result if the power is left on or is applied while the equipment is being installed. CAUTION Confirm that the power supply voltage is compatible with the voltage rating of the equipment. Connection to the wrong power supply can cause fire or equipment damage. Use the supplied power cable. Use of a wrong power cable can cause fire or equipment damage. Maintain the compass safe distance. Standard compass Steering compass 0.5 m 0.4 m Safety Information for the Operator WARNING Do not disassemble or modify the equipment. Fire, electrical shock or serious injury can result. Turn off the power immediately if water leaks into the equipment or the equipment is emitting smoke or fire. Continued use of the equipment can cause fire or electrical shock. Do not place liquid-filled containers on the top of the equipment. Fire or electrical shock can result if a liquid spills into the equipment. CAUTION Turns off the autopilot before selecting output data format. The autopilot may turn the rudder suddenly. Turns off the autopilot before aligning heading. The autopilot may turn the rudder suddenly. i iiiiiiiiiiiii i FOREWORD A Word to PG-1000 Owners Congratulations on your choice of the FURUNO PG-1000 Integrated Heading Sensor. We are confident you will see why the FURUNO name has become synonymous with quality and reliability. For over 50 years Furuno Electric Company has enjoyed an enviable reputation for innovative and dependable marine electronics equipment. This dedication to excellence is furthered by our extensive global network of sales and service. Your heading sensor is designed and constructed to meet the rigorous demands of the marine environment. However, no machine can perform its intended function unless operated and maintained properly. Please carefully read and follow the recommended procedures for installation, operation and maintenance. We would appreciate hearing from you about whether we are achieving our purposes. Thank you for choosing FURUNO equipment. Features • The PG-1000 uses a flaxgate magnetic sensor in conjunctions with solid-state angular rate sensor to find heading. • Automatic correction of magnetic variation • Can convert magnetic heading to true heading (requires Furuno GPS Navigator). TABLE OF CONTENTS SYSTEM CONFIGURATION.............................................................. iv SPECIFICATIONS..........................................................................SP-1 1 INSTALLATION 1.1 Equipment List .................................................................................................................... 1 1.2 Selecting Mounting Location .............................................................................................. 2 1.3 Mounting ............................................................................................................................. 3 1.4 Connections ......................................................................................................................... 4 1.5 Correcting Magnetic Field Distortion (Deviation) .............................................................. 5 1.6 Heading Alignment .............................................................................................................. 6 1.7 Setting Output Data ............................................................................................................. 6 2 CORRECTING MAGNETIC ANOMALIES 2.1 Controls and Indications ...................................................................................................... 8 2.2 Turning the Power On/Off ................................................................................................... 8 2.3 Automatic Distortion Compensation ................................................................................... 9 2.4 Selecting Output Data Format ............................................................................................. 9 3 MAINTENANCE & TROUBLESHOTTING 3.1 Maintenance....................................................................................................................... 10 3.2 Troubleshooting ................................................................................................................. 10 3.3 Diagnostic Test .................................................................................................................. 11 3.4 Displaying Program Version No. ....................................................................................... 12 PARTS LOCATION AND LIST...................................................... AP-1 OUTLINE DRAWING .........


Comentarios



Tu reseña
Tu nombre:
Introduzca dos números de la imagen:
capcha





Categoría