Iniciar sesión:
Votos - 3, Puntuación media: 3.7 ( )

Manual de usuario Graco Inc., modelo 150 RPX

Fabricar: Graco Inc.
Tamaño del archivo: 1.02 mb
Nombre del archivo: b9cc5caa-de70-4e9d-98b8-7fc5b07fd306.pdf
Idioma del manual:en
Enlace gratuito para este manual disponible en la parte inferior de la página



Resumen del manual


Flush the pump, In–line Valve and pressure roller immediately after each use to prevent paint from drying in the pressure roller and damaging it. Cleanup page 17. 14 309388 Rolling Techniques 1. Rolling vertically, roll out the letter “M”. 2. Cross roll, horizontally, to spread the paint. 3. Finish with light vertical strokes until the entire area has been evenly covered. 309388 15 Ceilings, Woodwork and Walls 1. Ceilings: Using a paint brush, apply a starting row of paint approximately the width of your brush where the walls and ceiling meet. 2. With the roller, apply paint to the ceiling, working the short way of the room and applying as wide a strip as possible. 1. Woodwork & Walls: Using a brush, paint woodwork first. Apply a starting row of paint approximately the width of the paint brush around the woodwork and where the walls meet the ceiling. 2. With the roller, apply paint to the walls, following the Roller Techniques described on page 15. 16 309388 Cleanup Leave the roller assembly attached to the In–line Valve for this procedure. 1. Relieve the pressure. Turn power switch OFF. 2. Remove roller cover and diffuser from roller frame as follows: a. Using your thumb, slide clip down and release end caps, diffuser, and roller cover into a pail. b. Remove roller cover from diffuser. c. Pull end caps off diffuser. 309388 17 Cleanup (continued) 3. Clean roller cover, caps and diffuser with water or a compatible solvent for non–water–based materials. Solvent Paint Solvent 4. Place roller frame in paint pail. Be sure the holes in the frame are facing inside the paint pail. 5. Place suction tube in bucket of water or compatible solvent for non–water–based materials. 6. Turn pressure control knob to roller symbol. 18 309388 309388 19 7. Turn power switch ON. Cleanup (continued) 8. Trigger In–line Valve. 9. Turn Spray/Prime valve to SPRAY. 10. Continue to trigger In–line Valve until flushing fluid begins to dilute paint. Then release In–line Valve trigger. 11. Place roller frame in another bucket. If you are flushing a non–water–based fluid, flush until fluid coming out of roller frame is clear. Proceed to page 25, Cleanup–Cleaning Contractor In–line Valve Filter. If water–based, follow Power Flushing procedure, page 20. 12. Relieve pressure, page 6. Turn power switch OFF. Solvent Cleanup – Power Flushing After Spraying Water–based Paint 1. Relieve pressure, page 6. Turn power switch OFF. Power Flush attachment 2. Screw Power Flush attachment onto garden hose. open closed garden hose close 3. Turn lever to close Power Flush attachment. WASTE inlet screen 4. Unscrew inlet screen from suction tube and place in waste pail. 20 309388 Cleanup – Power Flushing After Spraying Water–based Paint – (continued) 5. Connect garden hose to suction tube with Power Flush attachment. Leave prime tube in waste pail. Suction tube Power Flush attachment garden hose 6. Turn lever to open Power Flush attachment. Turn on garden hose. open 7. Align arrow on sprayer with bucket symbol on Pressure Knob. 8. Turn power switch ON. 309388 21 22 309388 9. Place roller frame in waste pail and trigger In–line Valve. Be sure the holes of the roller frame are facing inside the pail. 10. Turn Spray/Prime Valve to SPRAY. 11. Keep In–line Valve triggered for 1–2 minutes until somewhat clear water flows out of roller frame. Cleanup – Power Flushing After Spraying Water–based Paint – (continued) WASTE 1–2 MIN. WASTE Cleanup – Power Flushing After Spraying Water–based Paint – (continued) 12. Turn Spray/Prime Valve to PRIME. 13. Let water flow through sprayer into waste pail for 20 seconds. 20 SEC. WASTE 14. Turn Power Switch OFF. 309388 23 Cleanup – Power Flushing After Spraying Water–based Paint – (continued) 15. Close Power Flush. Turn off garden hose. closed 16. Unscrew Power Flush attachment from suction hose. 17. Remove roller frame and extension from In–line Valve. 24 309388 309388 25 1. Relieve pressure, page 6. 2. Push up on the trigger guard and swing it away from the trigger. 3. Unscrew the In–line Valve handle from the housing. Remove the filter and clean it in compatible solvent. NOTE: Do not soak the entire In–line Valve in solvent. Prolonged exposure to solvent can ruin the packings. Cleanup – Cleaning Contractor In–line Valve Filter 4. Apply Lithium–based greased to the threads of the In–line Valve handle and reassemble In–line Valve. Solvent Cleanup – Filling the Sprayer with Storage Fluid Always pump storage fluid through the pump system after cleaning. Water left in the sprayer will corrode and ruin pump. 1. Place suction tube in storage fluid bottle and prime tube in waste pail. WASTE prime tube suction tube 2. Turn Prime/Spray valve to PRIME. 3. Turn Pressure Control knob all the way left (counterclockwise) to minimum pressure. 26 309388 Cleanup – Filling the Sprayer with Storage Fluid 4. Turn power switch ON. 5. Align arrow on the sprayer with the (roller symbol) on the Pressure Control knob. 6. When storage fluid comes out of pr...

Otros modelos de este manual:
Otras herramientas - 309388 (1.02 mb)

Comentarios



Tu reseña
Tu nombre:
Introduzca dos números de la imagen:
capcha





Categoría