Iniciar sesión:
Votos - 5, Puntuación media: 4.2 ( )

Manual de usuario IBM, modelo EGX-400

Fabricar: IBM
Tamaño del archivo: 2.37 mb
Nombre del archivo: a7bec66f-799f-41f0-9580-343422d27153.pdf
Idioma del manual:enfr
Enlace gratuito para este manual disponible en la parte inferior de la página



Resumen del manual


In such cases, allow to warm up by running at about 15,000 rpm with no load for around 15 minutes. Chapter 1 - Getting Started 19 1-3. Installation and Cable Connections 1-3. Installation and Cable Connections s Make sure the power to the machine is switched off before attempting to connect or disconnect the cables. Connect securely to ensure that accidental disconnection does not occur during operation. Ground the unit with the ground wire. Failure to do so may result in risk of electrocution in the event of a mechanical problem. Use only with the power cord included with this product. Use with other than the included power cord may lead to fire or electrocution. Do not use with any electrical power supply that does not meet the ratings displayed on the unit. Use with any other power supply may lead to fire or electrocution. Connect the operation panel and the power cable. If you're using a computer, then also connect a printer cable or serial cable. The printer cable or serial cable is sold separately. Use a cable that is compatible with the computer. Printer cable Use a commercially available printer cable. Serial cable If your computer is an IBM AT-compatible personal computer, then use an optionally available XY-RS-34 cable (or equivalent). A straight cable such as a modem cable will not work. When the connection uses a serial cable, you need to make sure the communication parameters for the machine match the communication parameters for the computer. For more information about the computer's communication parameters, refer to the documentation for the program. The defaults for the programs included with this machine are set up to match without modification. Configuring the Communication Parameters for the Machine See p.109 "I/O Submenus" 20 Chapter 1 - Getting Started 1-3. Installation and Cable Connections 1-3. Installation and Cable Connections Do not insert an Ethernet cable or connect to a modular jack. Insert until it clicks into place. Operation-panel connector cable Rear Secure with the screws. Printer cable Serial cable Power connector Parallel connector Serial connector Serial portPrinter port Secure with the clips. Power outlet Power cord Connect either a printer cable or serial cable. Chapter 1 - Getting Started 21 22 2.2.n This chapter describes what you should know before you try to use the machine, such as the most basic operations and the procedures for safe use and handling. Be sure to read this chapter before you go on to the next step. Operating the buttons makes the machine move. When operating the buttons, be sure to keep your hands away from the machine. Do not let your hair, necktie, or the like touch the machine. There is danger of becoming it caught on the spindle or other moving parts. 2-1. Emergency Stop to Ensure Safety 2-1. Emergency Stop to Ensure Safety p To stop the machine in an emergency in order to avoid danger, press the emergency stop switch. The machine immediately stops operating and quits cutting. Cutting cannot be resumed. To Cancel an Emergency Stop To cancel an emergency stop, turn the emergency stop switch in the direction of the arrow. The machine returns to the state it was in immediately after powerup. Opening and Closing the Spindle Cover Be sure to close the spindle cover before you start cutting, and never open it while operation is in progress. For safety, opening the spindle cover during operation causes an emergency stop. To recover, switch off the power to the machine. When the spindle cover is open, only head movement using the movement buttons is possible. You cannot use the buttons to rotate the spindle or perform cutting. 24 Chapter 2 - Basic Operation 2-2. Switching the Power On and Off 2-2. Switching the Power On and Off r Keep your hands away from the machine when you turn on the power. Also, do not place and objects where they may obstruct the operation of the spindle head, X-axis rail, bed, or other components. Turning On the Power 1 1 Turn on the power switch on the back of the machine. The display shows the model name, and while this is displayed, internal initialization is performed. This takes about ten seconds. EGX-600 Roland DG Corp. 2 2 When the screen shown at right appears, press . This machine operates at this time. The spindle head moves to the left and back (to the VIEW position), then stops. 3 3 The display changes to the top screen, and startup ends. Switching Off the Power Turn off the power switch on the back of the machine. Do not the emergency stop switch for turning the power on and off in day-to-day use. Hit "ENTER" key X 0 Y 40700 Z 0 8000RPM Chapter 2 - Basic Operation 25 2-3. Moving the Spindle Head Do not put the operation panel on the machine while operation. Doing so may result in unexpected problems. 2-3. Moving the Spindle Head Do not put the operation panel on the machine while operation. Doing so may result in unexpected problems. d The spindle head moves in three directions, along the X, Y, and Z axes. When t...

Otros modelos de este manual:
Otras herramientas - EGX-600 (2.37 mb)

Comentarios



Tu reseña
Tu nombre:
Introduzca dos números de la imagen:
capcha





Categoría