Iniciar sesión:
Votos - , Puntuación media: ( )

Manual de usuario Adaptec, modelo Adaptec Serial ATA II RAID 1220SA

Fabricar: Adaptec
Tamaño del archivo: 196.2 kb
Nombre del archivo:

Idioma del manual:en

El documento se está cargando, por favor, espere
El documento se está cargando, por favor, espere

Resumen del manual


You need JVM version 1.3 or later. To check your JVM version, load JVM, type JAVA -VERSION. Note: For the latest updates from Novell, visit 1 Insert the Adaptec Storage Manager CD. Chapter 1: Getting Started with the Command Line Utility . 8 2 From the command prompt type load cdrom, then press Enter. From the command prompt, type: xx_yy_zz:\netware\manager\install where xx is the product CD, yy is the version number, and zz is the release number. For example: adptcd_v2_01 The installation program starts. 3 Follow the on-screen instructions to complete the installation. Installing on OpenServer and UnixWare To install ARCCONF on OpenServer and UnixWare systems or HRCONF on OpenServer: 1 Insert the Adaptec Storage Manager installation CD in the CD drive. 2 Mount the Adaptec Storage Manager installation CD: mount -r -F cdfs /dev/cdrom/cdromdevicefile /mnt where cdromdevicefile is the device file, for example, c0b0t010, for the CD block device. To determine the actual filename, look in the /dev/cdrom directory. 3 Use pkgadd to install Adaptec Storage Manager: pkgadd -d /mnt/unixware/manager/RaidMan.ds (for UnixWare) pkgadd -d /mnt/openserv6/manager/RaidMan.ds (for OpenServer 6) 4 Follow the instructions on the screen to complete the installation. 5 Unmount the CD drive: umount /mnt Installing on Solaris Note: HRCONF is not supported by systems running Solaris. To install ARCCONF on Solaris systems: 1 Insert the Adaptec Storage Manager Installation CD. The CD mounts automatically. (If it doesn’t, manually mount the CD using a command similar to the one shown below. Refer to your operating system documentation for detailed instructions.) mount -F hsfs -o ro/dev/dsk/c1t0d0s2/mnt 2 Install Adaptec Storage Manager: pkgadd -d//solaris/manager/StorMan.ds 3 Follow the on-screen instructions to complete the installation. Eject or unmount the Adaptec Storage Manager Installation CD. Refer to your operating system documentation for detailed instructions. Chapter 1: Getting Started with the Command Line Utility . 9 Starting the Command Line Utility To start ARCCONF or HRCONF, enter one of the following commands: . Windows—c:\\.exe . Linux—/usr// . NetWare—load . UnixWare/OpenServer—/opt/RaidMan/ . Solaris—/usr/StorMan/ Install_dir* is the directory where the utility is installed and name of utility is ARCCONF or HRCONF. To see a list of available commands, type ARCCONF or HRCONF at the prompt. The utility command functions are detailed in the next chapter, Using the Command Line Utility. Using the Command Line Utility 2 In this chapter... Understanding the Command Line Utility ........................................................................... ...

Otros modelos de este manual:
Otros componentes - Adaptec RAID 4000 (196.2 kb)
Otros componentes - Adaptec RAID 3805 (196.2 kb)
Otros componentes - Adaptec RAID 31605 (196.2 kb)
Otros componentes - Adaptec RAID 3085 (196.2 kb)

Comentarios



Tu reseña
Tu nombre:
Introduzca dos números de la imagen:
capcha





Categoría