Iniciar sesión:
Votos - 0, Puntuación media: 0 ( )

Manual de usuario Adaptec, modelo Adaptec RAID 5805

Fabricar: Adaptec
Tamaño del archivo: 25.24 kb
Nombre del archivo:
Idioma del manual:en
Enlace gratuito para este manual disponible en la parte inferior de la página



Otros manuales para este modelo:

Resumen del manual


The Adaptec Storage Manager User's Guide contains complete installation information for the Adaptec Storage Manager software. 2.2 Power Management Setup You must use a compatible combination of Adaptec Storage Manager and controller firmware and driver software to use the power management feature. All software components must support power management. You can download the latest controller firmware and drivers from the Adaptec Web site at 2.3 Linux Setup Page 2 readme.txt Before installing the Linux operating system on a logical device, Adaptec recommends clearing (removing) old data first. If you do not remove old data prior to installation, the OS may not boot. As a workaround, use the boot parameter 'aacraid.wwn=2'. 3. General Cautions -While an array is being built or cleared, do NOT remove and reinsert any drive from that array. Doing so may cause unpredictable results for any of the controller's arrays. -While a drive is being cleared, do NOT try to include it in a new array. Doing so may cause unpredictable results. -DO NOT move drives containing an array or volume from one controller to another while the power is on. Doing so could cause the loss of the array configuration or data, or both. Instead, power off both affected controllers, move the drives, and then restart. 4. Known Limitations 4.1 ACU Utility o On some Intel and IBM systems, when you try to run the ACU utility, this message appears: "Not enough free memory to load the utility! Press any key to attempt loading the utility forcibly OR Wait for the system initialization to be completed [Default]" This is normal. On Intel systems, wait for the system initialization to be completed. Then the ACU will run. On IBM systems, press any key when prompted to load the utility forcibly. o The ACU erroneously displays deleted logical drives in the JBOD list. The logical drive(s) continue to appear in the JBOD list until you delete all of the JBODs. o With some enclosures, the ACU displays incorrect box/slot information for managed disk drives; for example, Exp/Phy instead of Box/Slot. 4.2 Creating an Array from the Adaptec Storage Manager CD When you create an array with the Adaptec Storage Manager bootable CD, the maximum size of the array is 2 TB. 4.3 Using the Controller with an Adaptec S50 JBOD Enclosure Temperature warnings from the Adaptec S50 JBOD Enclosure with firmware version T016 are not shown in Adaptec Storage Manager (or on the enclosure). To correct the problem, upgrade to the latest firmware version. 4.4 UnixWare and OpenServer Adding or moving controllers in an existing UnixWare or OpenServer system may cause some device resources to change, which may lead Page 3 readme.txt to the operating system being unable to boot. Currently, there is no workaround available in the operating system. B...

Otros modelos de este manual:
Otros componentes - Adaptec RAID 5445 (25.24 kb)
Otros componentes - Adaptec RAID 5405 (25.24 kb)
Otros componentes - Adaptec RAID 52445 (25.24 kb)
Otros componentes - Adaptec RAID 51645 (25.24 kb)

Comentarios



Tu reseña
Tu nombre:
Introduzca dos números de la imagen:
capcha





Categoría