Manual de usuario Invacare, modelo IRC10LXO2

Fabricar: Invacare
Tamaño del archivo: 754.33 kb
Nombre del archivo:
Idioma del manual:en
Enlace gratuito para este manual disponible en la parte inferior de la página



Resumen del manual


It is an electronically operated device that separates oxygenfromroomair.Itprovideshighconcentrationofoxygen directly to you through a nasal cannula. Clinical studies have documented that oxygen concentrators are therapeutically equivalent to other types of oxygen delivery systems. Your provider will show you how to use your oxygen concentrator. He/She should be contacted with any questions or problems regarding your oxygen concentrator. This owner’s manual will tell you aboutyour concentrator andwill serve as a reference as you use your concentrator. Select a Location WARNING NEVER block the air openings of the product or place it on a soft surface, such as a bed or couch, where the air opening may be blocked. Keep the openings free from lint, hair and the like. Keep unit at least 3 inches away from walls, draperies, furniture, and the like. You may select a room where using your oxygen concentrator would be most convenient. Your concentrator can be easily rolled from room to room on its casters. The air intake of the unit should be locatedina well ventilated area to avoid airborne pollutants and/or fumes. DO NOT place in a closet. Platinum™ Series 16 Part No 1118353 SECTION 5—OPERATING INSTRUCTIONS Set-Up Plug in Power Cord Plug in power cord to an electrical outlet. POLARIZED PLUG WARNING As a safety feature, this appliance may have a polarized plug (one blade is wider than the other). This plug will fit in a polarized outlet only one way. If the plug does not fit fully in the outlet, reverse the plug. If it still does not fit, contact a qualified electrician. DO NOT attempt to defeat this safety feature. Connect Humidifier (If So Prescribed) WARNING DO NOT overfill humidifier. DO NOT reverse the oxygen input and output connections. Water from the humidifier bottle will travel through the cannula back to the patient. NOTE: For this procedure, refer to FIGURE 5.1, FIGURE 5.2 and FIGURE 5.3 on page 18 and FIGURE 5.4 on page 19. NOTE: For Platinum 5, XL .recommended humidifiers are: Invacare 3260, 003.40, or 006.40. For Platinum 10, recommended humidifiers are high flow: 7900.10, 7900.25. 1. Remove cap and fill humidifier bottle with distilled water to the level indicated by the manufacturer. 2. Replace the humidifier cap and securely tighten. Humidifier Bottle FIGURE 5.1 Filling the Humidifier Part No 1118353 17 Platinum™ Series SECTION 5—OPERATING INSTRUCTIONS Humidifier Bottle FIGURE 5.2 Humidifier Compartment 3. Remove the filter access door located on the side of the concentrator. Insert a flathead screwdriver in the plate groove on the top edge of the filter access door and gently pry the filter access door open. Refer to Detail “A” in FIGURE 5.3. 4. The humidifier adapter is next to the inlet filter. Pull up and remove the humidifier bottle adapter. Refer to Detail “B” in FIGURE 5.3. 5. Attach it to the humidifier by turning the wing nut on the humidifier bottle counterclockwise until it is securely fastened. Refer to Detail “C” in FIGURE 5.3. 6. Place the humidifier bottle in the humidifier compartment. DETAIL “A” Plate Groove (Insert Flat Head Screwdriver Here) Filter Access Door DETAIL “B” Humidifier Bottle Adapter Humidifier Bottle Adapter Filter Access Door DETAIL “C” FIGURE 5.3 Attaching the Humidifier Bottle Adapter Platinum™ Series 18 Part No 1118353 SECTION 5—OPERATING INSTRUCTIONS 7. Attach oxygen tubing from the humidifier bottle to oxygen outlet connector on the oxygen concentrator (FIGURE 5.4). 8. Attach the cannula/patient supply tubing to the humidifier bottle outlet (FIGURE 5.4). 9. After assembly, ensure that oxygen is flowing through the cannula. Oxygen Tubing Humidifier Outlet Oxygen Outlet Connector FIGURE 5.4 Attaching the Oxygen Tubing Power Switch NOTE: For this procedure, refer to FIGURE 5.5 on page 19. 1. Press power switch to on position. All the panel lights and the audible alarm will come on for one second, indicating that the unit is functioning properly. On/Off (I/O) Power Switch FIGURE 5.5 Power Switch Part No 1118353 19 Platinum™ Series SECTION 5—OPERATING INSTRUCTIONS Flowrate NOTE: For this procedure, refer to FIGURE 5.6 on page 20. 1. Turn the flowrate knob to the setting prescribed by your physician or therapist. CAUTION Never set the flow greater than 5 L/min on the IRC5. Never set the flow greater than 10L/min on the IRC10. WARNING DO NOT change the L/min setting on the flowmeter unless a change has been prescribed by your physician or therapist. NOTE: To properly read the flowmeter, locate the prescribed flowrate line on the flowmeter. Next, turn the flow knob until the ball rises to the line. Now, center the ball on the L/min. line prescribed. 2. If the flowrate on the flowmeter ever falls below 0.5 L/min for Platinum 5 (1 L/min for Platinum 10) for more than about one minute, the LOW FLOW alarm will be triggered. This is a rapid beeping of the audible alarm. Check your tubing or accessories for blocked or kinked tubing or a defective humidifier bottle. Aft...

Otros modelos de este manual:
Otros dispositivos personales - IRC10LX (754.33 kb)
Otros dispositivos personales - IRC5LX (754.33 kb)
Otros dispositivos personales - IRC5LXO2 (754.33 kb)

Comentarios



Tu reseña
Tu nombre:
Introduzca dos números de la imagen:
capcha





Categoría