Fabricar: JVC
Tamaño del archivo: 56.73 kb
Nombre del archivo: baff9b2c-d722-8284-f908-3c646a4edc9a.pdf
|
Resumen del manual
LCT0811-001A The following instructions will tell you how to safely replace the projection lamp. Please read these instructions fully before attempting to replace the lamp. If you feel unsure about replacing the lamp, call a service technician. WARNING! It is very important you DO NOT TOUCH THE GLASS SURFACE OF THE NEW LAMP. Touching the glass surface will deposit oils from your hand onto the lamp surface. When the lamp heats up to operating temperature, the oil will cause a difference in temperature on the lamp surface. This will likely cause the lamp to break. This lamp is only for use with the AV-61S902. It is designed to work specifically with the AV-61S902. Using this lamp with a different television or other product could cause a malfunction and/or damage to the television or the lamp. Under operating conditions THE LAMP WILL GET EXTREMELY HOT AND WILL CAUSE SEVERE BURNS IF TOUCHED. Before attempting to replace the lamp, make sure the television has run through its cooling cycle (indicated by the front panel LED lights) and that the television is unplugged. If you feel any warmth coming from the lamp DO NOT TOUCH IT. Wait until the lamp has fully cooled before attempting to replace it. NEVER attempt to replace the lamp with the television plugged into a wall outlet. Attempting to replace a lamp with the television plugged in could lead to a severe electrical shock. This kit also includes instructions on recycling the used lamp. Because the lamp contains a small amount of mercury, it cannot be disposed of with normal trash in the U.S. Packaging, with a pre-paid shipping label for returning the lamp to a JVC-authorized recycling center for recycling, is included with the replacement lamp. See the included sheet and page 63 in the AV-61S902 User’s Guide for details on recycling information for customers in the United States. Check the accessories Check that nothing is missing. The kit will include: • High-Pressure Mercury Lamp • Hex Wrench • Replacement Instructions • Recycling Information Sheet • Pre-paid shipping label Replacing the Lamp 1) Turn the television off. Press the Power button on the remote control or television’s front panel to turn the television off. Wait until the picture has closed and the LED lights on the front panel have stopped blinking indicating the lamp cool-down cycle is complete. Warning: The cool-down cycle cools the lamp from its normal operating temperatures. This does not mean the lamp will now be cool enough to handle safely. Wait at least one hour before proceeding. 2) Unplug the television. Disconnect the television’s power cord from the AC outlet. Make sure the LED lights have stopped blinking before you unplug the television. Never attempt to replace the lamp with the television plugged in. Continued on the next page 1. Pull 2. Lift Speaker Panel 1. Pull 2. Lift Speaker Panel 3) Remove the left speaker panel. The next step is to remove the left speaker panel located at the bottom of the front of the television cabinet. Make sure the television is unplugged (see steps 1 and 2) before removing the speaker panel. To remove the panel - Grab the panel from the side near the top. Gently pull the top away from the television. When the top part of the speaker panel is fully away from the television, lift up. The panel will come away from the bottom of the television. Set the panel aside. 4) Remove the filter cover. The lamp is located behind the air filter. To access the lamp you will need to remove this filter assembly and the filter panel covering it. To remove this panel you will need a Phillips head screwdriver. First loosen the screws located at the four corners of the Screws panel. Once the screws have been loosened, slide the cover up until the large holes align with the screw heads. Gently pull the panel away from the television and set aside. (Please see Appendix A for illustrations for removing the speaker and filter covers). Filter Cover 5) Removing the filter assembly. Next you will need to remove the filter Interlock switch assembly. To remove the assembly, use a coin to loosen the three large- slotted screws fastening the filter assembly. When the screws have been Coin etc. loosened, slide the filter assembly out to remove it. • Do not touch the surface of the filter or try to remove it from the filter assembly. These actions could damage the filter. If the filter is damaged, call a service technician to replace the filter. WARNING: DO NOT attempt to remove the assembly until the lamp has fully cooled down. If you feel any heat near the lamp assembly, STOP the removal and wait until the lamp has FULLY COOLED. NEVER attempt to remove the lamp assembly with the television plugged into a wall outlet. DO NOT DROP the used lamp. The inside of the lamp is under pressure. Dropping or other hard shock could cause the lamp to shatter. ALWAYS recycle the used lamp. Because the lamp contains a small amount of mercury it cannot be thrown out with regular trash. Follow the re...