Iniciar sesión:
Votos - 0, Puntuación media: 0 ( )

Manual de usuario HP, modelo HP StorageWorks Clustered Gateway Device Management Software

Fabricar: HP
Tamaño del archivo: 279.05 kb
Nombre del archivo:
Idioma del manual:en
Enlace gratuito para este manual disponible en la parte inferior de la página



Otros manuales para este modelo:

Resumen del manual


ID
Message and Corrective Action
This cluster is unable to take control of SAN, because the servers are unable to
perform fencing operations, possibly due to a networking or fencing hardware
failure or misconfiguration. As a result, some or all filesystem operations may be
paused throughout the cluster. In addition, filesystem mounts and unmounts and
disk imports and deports can not be performed.
17005
Action. HP Scalable NAS is unable to exclude servers that have become
unresponsive, or to verify the fencing of servers that were previously fenced and
have not yet been rebooted. Possibly the fencing device is not responding to the
fencing request or the Ethernet connection to the FibreChannel switch has failed.
Also check for other networking or SAN hardware problems. The servers should
be rebooted as soon as possible.
This cluster takes control of SAN failure resolved.
17006
Action. None. Alert 17005 is resolved.
This cluster unable to take control of SAN, because the servers are unable to write
to a majority of the membership partitions, possibly due to a SAN hardware failure
or misconfiguration and/or because some servers have been excluded from the
SAN. As a result, some or all filesystem operations may be paused throughout the
17007
cluster. In addition, filesystem mounts and unmounts and disk imports and deports
cannot be performed.
Action. Check the cluster configuration and add the server if it is not currently a
member. Also ensure that the server can access the membership partitions and
has write access to them, and check for any SAN hardware problems.
This cluster takes control of SAN failure resolved.
17008
Action. None. Alert 17007 is resolved.
This cluster unable to take control of SAN, because a majority of the membership
partitions cannot be written or are corrupt, possibly due to a SAN hardware failure
or misconfiguration and/or because servers have been excluded from the SAN.
As a result, some or all filesystem operations may be paused throughout the cluster.
In addition, filesystem mounts and unmounts and disk imports and deports cannot
17009
be performed.
Action. Ensure that all servers can access the membership partitions and have write
access to them. If a membership partition is corrupt, another alert will specify its
location. See “Membership partitions” in the HP Scalable NAS File Serving
Software administration guide
for corrective actions.
This cluster takes control of SAN failure resolved.
17010
Action. None. Alert 17009 is resolved.
HP Scalable NAS File Serving Software event notification guide
35


...

Otros modelos de este manual:
datos de dispositivos de procesamiento - HP DL380 - WSS Clustered Gateway (279.05 kb)
datos de dispositivos de procesamiento - HP DL380-SL Clustered Gateway (279.05 kb)
datos de dispositivos de procesamiento - HP ProLiant DL380G5-WSS Storage Server Clustered Gateway (279.05 kb)
datos de dispositivos de procesamiento - HP ProLiant DL380G5-WSS Storage Server Initial Cluster (279.05 kb)

Comentarios



Tu reseña
Tu nombre:
Introduzca dos números de la imagen:
capcha





Categoría