.. relative gain adjustments. Argument details Name Description Units Device 0–7 or * to select all units MAX Command form Channel See Groups and Channels, page 97 Group I,O,M,P,L Value -65.00 to 20.00 dB Null to return the current setting Example: #51 MAX 2 M 10 On XAP 800 unit 1 (#51), the maximum (MAX) relative gain setting for mic (M) channel 2 is 10dB. Technical Services Group ~ 1-800-283-5936 (USA) ~ 1-801-974-3760 Appendices ~ Appendix E: Serial Commands MDMODE - Modem Mode This command enables or disables the modem mode for the unit. When the modem mode is enabled, the modem initialization string is sent out the serial port and the serial port now requires a password before a command is processed. After five minutes of serial inactivity the passcode will be requested to continue serial activity. Command form: DEVICE MDMODE [Value] Argument details Name Description Device 0–7 or * to select all units MDMODE Command form Value 0 = Off, 1 = On, 2 = Toggle, Null = current modem mode state Example: #57 MDMODE 1 On XAP 800 unit 7 (#57), the modem mode (MDMODE) is on (1). MIN - Minimum Gain Setting This command changes or reports back the minimum gain setting for an input, output or assignable processing block. Command form: DEVICE MIN [Value] Argument details Name Description Units Device 0–7 or * to select all units MIN Command form Channel See Groups and Channels, page 97 Group I,O,M,P,L Value -65.00 to 20.00 dB Null to return the current setting Example: #54 MIN 2 M -10 On XAP 800 unit 4 (#54), the minimum (MIN) relative gain setting for mic (M) channel 2 is -10dB. Technical Services Group ~ 1-800-283-5936 (USA) ~ 1-801-974-3760 116 116 Appendices ~ Appendix E: Serial Commands MINIT - Modem Initialization String This command sets/reports the modem initialization string of the serial port when in modem mode. Command form: DEVICE MINIT [String] Argument details Name Description Device 0–7 or * to select all units MINIT Command form String 1-80 characters (select string characters to be sent to the modem when the unit is initialized CLEAR = clears the modem initialization string Null = Current string Example: #56 MINIT ATZ On XAP 800 unit 6 (#56), the modem initialization string (MINIT) is ATZ. MINMAX - Minimum and Maximum Gain Setting This command changes or reports back the minimum and maximum gain setting for an input, output or assignable processing block. Command form: DEVICE MINMAX [Minimum] [Maximum] Argument details Name Description Device 0–7 or * to select all units MINMAX Command form Channel See Groups and Channels Group I,O,M,P,L Minimum -65.00 to 20.00, Null to return current settings Maximum -65.00 – 20.00 Example: #55 MINMAX 2 M -12 10 On XAP 800 unit 5 (#55), the minimum and maximum (MINMAX) relative gain settings for mic (M) channel 2 are -12dB and 10dB respectively. Technical Services Group ~ 1-800-283-5936 (USA) ~ 1-801-974-3760 Appendices ~ Appendix E: Serial Commands 117 MLINE - Mic/Line Adjust This command selects/reports the setting of coarse gain adjustment on the input channels 1-8.The three settings are 0dB, 25dB, and 55dB. Command form: DEVICE MLINE [Value] Argument details Name Description Device 0–7 or * to select all units MLINE Command form Channel 1–8 (selects mic inputs) Value 0 = 0dB (line level), 1 = 55dB, 2 = 25dB, Null = current level Example: #53 MLINE 1 2 On XAP 800 unit 3 (#53), the mic/line (MLINE) setting for input 1 is 25dB (2). MMAX - Maximum Number of Microphones This command selects/reports the maximum number of microphones for each gating group. Command form: DEVICE MMAX [Value] Argument details Name Description Device 0–7 or * to select all units MMAX Command form Channel 1–4, A-D (gating groups) Value 0 = Unlimited, 1–8 = Maximum number of mics Null = Current maximum number of microphones Example: #52 MMAX A 4 On the XAP 800 unit 2 (#52), the max number of mics (MMAX) in gating group A that are allowed to gate on at any one time is 4. MPASS - Modem Password This command sets the current password setting for the unit when using modem mode.The password must be entered in twice. Command form: DEVICE MPASS [String] Argument details Name Description Device 0–7 or * to select all units MMAX Command form String 0-12 characters, CLEAR = to clear the current password Null to report the current password Example: #50 MPASS GENTNER On XAP 800 unit 0 (#50), the modem password (MPASS) is set to GENTNER. . .. Once the command is given, the unit responds by echoing back the command, followed by “REENTER PASSWORD” string. The command must then be re-entered exactly as entered previously.Then, the command will be echoed back, followed by an “OK,” indicating that the password has been changed. Technical Services Group ~ 1-800-283-5936 (USA) ~ 1-801-974-3760 118 118 Appendices ~ Appendix E: Serial Commands . .. SRC = source DEST = destination CHNL = channel GRP = group . .. Values indicate entry range only. Actual interna...