Iniciar sesión:
Votos - 3, Puntuación media: 4.3 ( )

Manual de usuario Channel Plus, modelo TELEPHONE DISTRIBUTION MODULE DMT-16

Fabricar: Channel Plus
Tamaño del archivo: 200.46 kb
Nombre del archivo: DMT-16.pdf
Idioma del manual:en
Enlace gratuito para este manual disponible en la parte inferior de la página



Resumen del manual


4. The user is responsible for all labor costs associated with removing, reinstalling and returning the product to Linear LLC. Linear LLC, at its option, will repair or replace the defective product. Replacements will be made from B-Stock, if an exact replacement is not available, Linear LLC, at its option, will select the nearest equivalent product. The user is responsible for freight charges to Linear LLC. Linear LLC will return warranted repaired or replacements by UPS Ground or an equivalent service. A customer may pay the additional costs for second-day or next-day service. All products returned for warranty service require a Return Product Authorization Number (RPA#). Contact Linear Technical Services at 1-800-999-5225 for an RPA# and other important details. B) Never install telephone jacks in a wet location. A) Never install telephone wiring during a lightning storm. D) Use caution when installing or modifying telephone C) Never touch uninsulated telephone wires or terminals unless the telephone line has been disconnected network interface. SAFETY INFORMATION: IMPORTANT INSTRUCTIONS: When you use your telephone equipment, basic precautions should always be followed to reduce the risk of fire, electric shock and injury to persons, including the following: 1. Read and understand instructions. 2. Do not use this product near water, for example, near a bathtub, wash bowl, kitchen sink, or laundry tub, in a wet basement, or near a swimming pool. 3. Never push objects of any kind into this product through they may touch dangerous voltages. 4. Use on UL listed cabinets the H218A, H236A, or SAVE THESE INSTRUCTIONS 600-230 C Copyright © ® Telephone Distribution Module Line Ringing ® Model DMT-16 Designed for ChannelPlus and OpenHouse structured wire grid systems. 2005 Expansion Jumper (included) Install this jumper for normal operation. Remove to disconnect telephone service from the system. Each line is individually surge protected to 50 Joules and 4000 Amps. Some surges contain sufficient energy that although your system has been protected, the surge circuit will be unable to provide additional protection. When this happens, the red light for that line will turn on and the module needs to be returned for service. From telephone company 4 Lines 4 Lines to 16 telephone wall plates. Security system connection (RJ-31X) Telephone Distribution Module DMT-16 Active Line Indicators Typical Installation Family Room Guest House 2 Basement Bathroom Bedroom 4 Bathroom 1 Bathroom 3 Bedroom Bedroom 1 Bedroom 2 Bedroom 3 Bathroom 2 Back Door Master Suite 2 Dining Room Game Room Garage Garage 2 Guest House 1 Family Room FAX FAX 2 Fitness Center Front Door Guest House Bedroom 6 Bedroom 7 Bedroom 5 Den Den 2 Children’s Room Children’s Room 1 Children’s Room 2 Children’s Room 3 Children’s Room 4 Satellite Satellite 1 Satellite 2 Satellite 3 Satellite 4 Patio Play Room Pool House PVR PVR 1 Master Suite 3 Master Suite 4 Media Center Media Center 1 Media Center 2 Modem 2 Modem Office Office 1 Office 2 Office 3 Guest Room Guest Room 2 Hall Hall 2 Kitchen Laundry Room Living Room Master Suite Master Suite 1 Guest Room 1 Bat Phone Label Card: Separate and slide labels into extrusion, or flip the label over for a blank surface. Front Rear Example 2 Included: (1) Expansion Jumper 24”. (2) Flat Surface Mounting Ears. (1) Disconnect Jumper (66) Labels Line Ringing ® 3 Black Green Yellow Red Pairs 1 & 2 Pairs 3 & 4 Option: old style wall plate Pairs 3 & 4 Pairs 1 & 2 RJ-14 Voice Grade Jacks Cable Color Pin # Connector Color Pin 1 White/Orange Pin 2 White/Orange Blue Pin 3 Blue White/Blue Pin 4 White/Blue Orange Pin 5 Orange Pin 6 N/C N/C Cable Color Pin # Connector Color Pin 1 White/Brown Pin 2 White/Orange Green Pin 3 Blue White/Green Pin 4 White/Blue Brown Pin 5 Orange Pin 6 N/C N/C 8 position connectors T RT RT RT R 1 2 3 4 5 6 7 8 PR2 PR3 PR1 PR4 RJ-11 Single line telephones, RJ-14 Dual line telephones & RJ-25 Rare 3 line KSU RJ-45 (wired to TIA T568A standard) Ethernet (both 10BaseT and 100BaseT) Structured wiring of phones and data lines Follow color code for T568A jacks. Position first pair to channel closest to end of jack. (Do not untwist conductor pairs more than 0.5" from the termination point.) Keep sheath close to jack. 1 Using a 110 punch-down tool, push wires into channels Repeat for subsequent pairs. and trim. 110 punchdown tool 2 When all conductor pairs are terminated, snap on strain relief caps. 3 Wiring a Cat-5 jack Keep sheath close to connector Untwist .5” max. 110 punch down tool Note order of colors Wiring a telephone wall plate Black Green Yellow Red Wiring a 110 connector green black white red yellow blue TIP TIP TIP TIP RING RING RING RING Cat5 4 pair UTP blue/white blue orange/white orange green/white green brown/white brown pair 1 pair 2 pair 3 pair 4 pair 1 pair 2 pair 3 Solid Color Twisted-Pair Wire Modular connectors 6 position connectors RT T RT R T T RT RR 1 1 1 2 2 2 3 3 3 4 4 4 5 5 5 6 6 6 PR2 PR1 PR...


Comentarios



Tu reseña
Tu nombre:
Introduzca dos números de la imagen:
capcha





Categoría