Iniciar sesión:
Votos - 2, Puntuación media: 3.5 ( )

Manual de usuario ADTRAN, modelo 624

Fabricar: ADTRAN
Tamaño del archivo: 2.42 mb
Nombre del archivo:
Idioma del manual:en
Enlace gratuito para este manual disponible en la parte inferior de la página



Resumen del manual


For example, if the timer expires but the switch continues to request battery removal, the Total Access 6XX will follow the switch and continue to remove battery. For ATM mode, if the timer is set to IGNORE SWITCH, the IAD will never remove battery. Press on the TANDEM [+] option to view the TANDEM options if the port mode is set to TANDEM (E&M). Set the CONVERSION MODE of the port to either LOOP START or GROUND START. Set the SUPERVISION of the port to either IMMEDIATE or WINK. Be sure to set the TANDEM options for each port set to TANDEM E&M. 2. Configuring the Layer 2 Protocol From the main menu, select L2 PROTOCOL and press . Use the arrow keys to select the PROTOCOL field for the T1 interface. Press . Select ATM from the list of available protocols. Use the arrow keys to select the CONFIG menu for the T1 interface and press . Highlight the ATM CONFIG menu for the T1 interface and press . Enter the IDLE CELLS format for your network. Set DATA SCRAMBLING appropriately for your network. Back all the way out to one level to the PVC CONFIG menu, and press . Enter the VPI and VCI values for communicating with that Gateway. (From this menu, the appropriate Voice information for working with the Voice Gateway is entered by selecting VOICE under the CONNECTION field.) Select SETUP, and from the SETUP menu, enter the Gateway type under CALL CONTROL and enter the VPI and VCI values for communicating with that Gateway. For this application, CALL CONTROL and virtual identifier (VPI and VCI) values should be set appropriately for your network. To verify correct setup, use the PVC STATUS menu (under the STATUS menu located at L2 PROTOCOL [0] > STATUS) to look at the current status of the voice connection. Under STATUS, view information about the voice PVC along with information about the POTS ports available on the unit. Appendix B. RFC1483 Quick Start (IP Routing) Figure 10. Application Diagram Initial Setup 1. Setting up the Interfaces From the main menu, select INTERFACES. 2 Highlight the CONFIG menu for the T1 interface and press . 3 Right arrow to select FORMAT and choose ESF or SF. This format must match the format used by the other units in the network. Set the LINE CODE to B8ZS or AMI. This line code must match the line code used by the other units in the network. Set the EQUALIZATION or line build out. The default setting of 0 DB is usually sufficient. Set the CSU LPBK option to ENABLE, DISABLE, or DISABLE ALL based on whether looping to this unit from another unit will be allowed. From the main menu, select INTERFACES. 2 Highlight the CONFIG menu for the ETH interface and press . 3 Use the right arrow to select AUTONEGOTIATION and press . Use the down arrow to choose OFF. Select the DATA RATE field and specify either 10BASET or 100BASET. Select the DUPLEX TYPE field and specify either HALF DUPLEX or FULL DUPLEX. .2. Configuring the Layer 2 Protocol From the main menu, select L2 PROTOCOL and press . Use the arrow keys to select the PROTOCOL field for the T1 interface. Press . Select ATM from the list of available protocols. Use the arrow keys to select the CONFIG menu for the T1 interface and press . Highlight the ATM CONFIG menu for the T1 interface and press . Enter the IDLE CELLS format for your network. Set DATA SCRAMBLING appropriately for your network. Back all the way out to one level to the PVC CONFIG menu, and press . Enter the VPI and VCI values for communicating with that Gateway. Select ROUTER under the CONNECTION field. Select the SETUP menu and configure the virtual circuit for IP or PPP operation. (Our example selects IP.) Refer to L2 Protocol (ATM–NET–ATM) > Config > PVC Config > Setup (Router) on page 103 for more details. Set mode to ROUTE IP. Using this menu you also have the option to route only IP packets and bridge all other data packets (ROUTE IP/BRIDGE OTHER) or bridge all data packets on this connection (BRIDGE ALL). Refer to L2 Protocol (ATM–NET–ATM) > Config > PVC Config > Setup (Router) on page 103 for more details. Left arrow back to the main menu to save the changes. 3. Setting the Router Options From the main menu, select ROUTER and press . Use the right arrow key to highlight CONFIG and press . Select INTERFACES and press . Use the right arrow key to highlight the SETUP field for the ETH (Ethernet) interface and press . Highlight the PRIMARY IP field and press . Set the IP ADDRESS of the Ethernet port. Set the SUBNET MASK for the Ethernet port. By default, RIP is disabled on the Ethernet interface. If RIP needs to be enabled, highlight the RIP field and press . Set the appropriate VERSION, RIP METHOD, DIRECTION, and V2 SECRET (where applicable) to configure RIP on the interface. For more details, refer to Router > Config > Interfaces (ETH) > Sub-Interface on page 120. Press the left arrow key to return to the Ethernet sub-interface menu (...

Otros modelos de este manual:
Teléfonos fijos - 604 (2.42 mb)
Teléfonos fijos - 606 (2.42 mb)
Teléfonos fijos - 612 (2.42 mb)
Teléfonos fijos - 616 (2.42 mb)

Comentarios



Tu reseña
Tu nombre:
Introduzca dos números de la imagen:
capcha





Categoría