Iniciar sesión:
Votos - 3, Puntuación media: 4.3 ( )

Manual de usuario Aiphone, modelo IP MULTIFUNCTIONAL MASTER STATION AN-8500MS

Fabricar: Aiphone
Tamaño del archivo: 222.88 kb
Nombre del archivo: AN-8500MS_Install.pdf
Idioma del manual:en
Enlace gratuito para este manual disponible en la parte inferior de la página



Resumen del manual


0 Before installation or use, be sure to carefully read all the instructions in this section for correct and safe operation. 0 Be sure to follow all the precautionary instructions in this section, which contain important warnings and/or cautions regarding safety. 0 After reading, keep this manual handy for future reference. Indicates a potentially hazardous situation which, if mishandled, could result in moderate or minor personal injury, and/or property damage. When the Unit is in Use 0 Use the dedicated AC adapter or its equivalent for the unit. Note that the use of other adapter may cause a fire. 2. GENERAL DESCRIPTION The AN-8500MS is an IP multifunctional master station designed for use with AIPHONE's network intercom system that employs the packet audio technology*'. Connecting the IP multifunctional master station to a network permits the ideal system for in-house or wide-area information transmission applications, such as paging, periodical broadcasts, and background music broadcasts, to be built in combination with the AN-8000MI Multi interface unit and AN-8000EX IP Intercom Exchange. Using an optional YC-280 Wall mounting bracket, the station can be mounted on a wall, or tilted for easy key operation when used on a desktop. *' Technology related to audio transmission over a network. 3. FEATURES Clear conversations between stations over wide band. The system's echo cancellation*2 feature makes hands-free duplex conversation possible (conversations made without using a handset at both parties) between stations. Can be connected to an existing local area network (LAN) or wide-area network (WAN). The system can also be easily connectedto fiber-optic networks without restrictions on operating distance. 0 The dedicated software program enables centralized control with a personal computer. * System maintenance (verifying operation log and line supervision) can also be performed with a personal computer and Internet browser. 0 Connecting the station to a PoE (Power over Ethernet) switching hub eliminates the need for an AC adapter. A PC can be cascaded with the station. If power is not supplied to the station, hub function will not work. ** A circuit that prevents acoustic feedback or echo generated when the voice output from the station's internal speaker enters the microphone. 4. WHEN MOUNTING THE STATION ON A WALL When mounting the station on a wall, the orientation of the handset hook needs to be changed. Step 1. Raise the number directory cover forward tab. Number directory covet Step 2. Remove both the number directory cover and the directory. Remove the handset hook and reverse its orientation, then replace. Step 3. After replacing the directory on the station, hook the directory cover's forward tab and push on the upper part of the directory cover. 5.WALL MOUNTING The optional YC-280 Wall mounting bracket is required. The YC-280 can be mounted to a one-gang electrical box. 5.1. Mounting Step 1. Install the YC-280 to the wall Notes iting 0 Use the appropriate screws for the construction of wall. 0 Wood screws 3.5 x 20 are supplied with the YC-280. 0 No fitting screws for an electrical box are supplied. Use commercially available screws. Step 2. Hang the station on the wall mounting bracket hook to install. Push down the station body in the direction indicated by the arrows. Wood screw 3.5 x 20 (suppliedwith the YC-280) 5.2. Installation Completion Drawing 5.3. YC-280 Dimensional Drawing Unit: mm 4.6 x 6 Unit: mm 148 YC-280 K-IN In desktop installations, the front operation panel can be inclined 16" from the desk surface for easier operation by attaching the YC-280 Wall mounting bracket to its bottom surface. 6.1. Mounting 6.2. Installation Hang the YC-280's hook on the station's wall bracket mounting slot to install. t-205.2 Unit: mm Push up the YC-280 in the direction indicated by the arrows. YC-280 Wall YC-280 AN-8500MsA h mounting bracket ~~ Rubber foot Hook the YC-280) 7.WIRING Power supply connection The following 2 methods are available for AN-8500MS rear supplying power to the station. 0 From a DC 12 V AC adapter From an IEEE802.3af compliant PoE switching hub (For connection, refer to the instruction 12V-4WmA manual supplied with the switching hub.) AC adapter connection Cable <>-T-T> Connect the AC adapter*. Install the supplied ferrite clamp on the AC adapter cable by winding the cable around the ferrite clamp once Ferrite clamp (accessory) * Use the AC adapter AD-121 OP (optional) or the equivalent. b As for the usable adapter, consult the AIPHONE sales Off PC connection External speaker connection Use a UTP category 5 straight- through cable with an RJ-45 Press down the desired push- connector for this connection. in terminal button with a tip of standard driver, and insert the cable securely. 11 mm * Applicable cables are as follows. Can be connected to a network of IOBASE- COM HOT Conductor diameter: TI1 OOBASE-TX in auto-sensing. 00.4 -1.3 mm (AWGI 6 -26), Solid wire Use a UTP catego...


Comentarios



Tu reseña
Tu nombre:
Introduzca dos números de la imagen:
capcha





Categoría