|
Resumen del manual
DO NOT HOLD HOOK SWITCH DOWN WHILE PICKING UP HANDSET. THE CALL TONE SOUNDS THRU THE HANDSET RECEIVER ELEMENT AND COULD CAUSE HEARING DAMAGE. * Installation; 1. DO NOT CONNECT ANY TERMINAL ON ANY UNIT TO AC POWER LINES. 2. Be sure to remove plug of power supply from AC outlet before you open the unit or make wiring connections. 3. Avoid running the connecting wires thru doors, windows or between furniture, which may pinch and disconnected the wires. 4. The intercom equipment must be installed in as dry and dust-free environment as possible. * Maintenance; 1. Clean your intercom equipment with a soft cloth dampened with neutral household cleanser. Never use thinner nor benzine, etc. 2. Do not splash water on the door station by hose, etc. NEVER COMPONENTS AVAILABLE FOR USE IN THE TB-T SYSTEM Jr Ù' ■ ih w TB-10T: 10-call master. TB-20T: 20-call master. TB-20AS: Add-on selector for 20 additional sub stations. •r\ PA-T: Paging adaptor. Connects TB-T master to a paging system and background music system. PG-10A, PG-30A, PG-60A: UL & CSA LISTED paging amplifier. 10W, 30W, 60W (for North America only). PG-10B, PG-30B, PG-60B: Standard paging amplifier. 10W, 30W, 60W. SP-3NA: Ceiling mount speaker. Install with or without NBZ-M square frame. TB-40AS: Add-on selector for 40 additional sub stations. DB-TS: Door station adaptor (required for each door station) TB-RC: Substation. TB-RC (R): Sub station with red case. ICR-1: Call extension. ■ Door stations; All weather resistant type. LED mounted on each cover. IC-DC IC-NA IC-RA IC-KA IC-JA ACTUAL TERMINAL LOCATIONS ,c fy The master station terminal block is located on back of the cabinet. IC-DA-R 1D-DA ID-NC fT)— (20) i for connecting s x 1 sub station (E ) (cÿ j for connecting x ( master station (mV (^s) , (IT) .. for connecting call extension speaker @, (^) .. for power supply to the door station adaptor NOTE: For connecting master station and additional selector, joint each connector on back of the cabinet. -2- WALL MOUNTING INSTALLATION MASTER STATION: (1) When wall mounting, install sub chassis upside down. (2) When mounting to a gang box, use sub plate (available from Aiphone) as shown in the figure. NOTE: Sub chassis must be ALWAYS used for heat SUB STATION: Attach the mounting bracket to wall or gang box. TERMINALS WIRING Layout your system in advance. Determine the location of each station and wiring to each. Two conductors are required from a master to each sub station under control of that master. Three conudctors are required between the two masters. Door station adaptor DB-TS should be located as near master as possible. Three conductors are required to DB-TS. * Connect a single pair of wires (non-polarized) to TB-RC phone, and to numbered station terminals on master station which you wish to call. * Adjust call tone volume as desired on the panel of master. * Do not common one side of pair at any other point than at master. Doing so will affect proper operation of your system. Refer to the connection diagrams. * Extend a single pair of wires from terminals: S, S on master to ICR-1, extension call speaker in places where you wish to receive a call besides at master. Refer to the chart below and select the proper size wire for your needs. 24 AWG 22 AWG 20 AWG 18 AWG Master to sub 750’ 1,300' 2,000' 3,000' Master to master 400' 650' 1,000' 1,600' DB-TS to door station 300' 500' 750' 1,200' 0.5 mm 0.65 mm 0.8 mm 1.0 mm Master to sub 230 m 400 m 600 m 900 m Master to master 120 m 200 m 300 m 480 m DB-TS to door station 90 m 150 m 230 m 360 m After installation of a master and one sub station, we recommend that the system be turned on and tested for proper operation. The system should further be tested after the addition of each five stations. INSTALLATION OF DOOR STATION 1. Terminal N indicates the number to which door will announce. 2. DB-TS should be mounted so as to keep wiring to the master as short as possible. 3. Mount door station to wall or gang box as desired. 4. Connect terminals 1 and 2 on DB-TS to door station. Wiring is non-polarized. 5. Connect terminals + and — to master station. Observe polarity. NOTE: DB-TS can not be connected to additional selector. -3 - INSTALLATION EXAMPLE #(1) : TB-10T w/9 TB-RC & 1 door station * The master station may select and call up to two sub stations simultaneously, except including door station. * Install DB-TS door station adaptor as near master station as possible. * A door station may be connected to either master station but can not be connected to two masters. -4- INSTALLATION EXAMPLE # (2) : TB-10T w/additional selector & 30 TB-RC CONNECTION OF TB-T MASTER TO ADD-ON SELECTOR The provided connector allows easy plug-in connection between master and additional selector. INSTALLATION OF CALL EXTENSION: ICR-1 CONNECTOR A call extension device: ICR-1 may be added to each master station so as to signal calls in a room o...
Otros modelos de este manual:Teléfonos fijos - TB-20T (442.11 kb)