Iniciar sesión:
Votos - 3, Puntuación media: 4 ( )

Manual de usuario AMX, modelo Mio Modero R-2

Fabricar: AMX
Tamaño del archivo: 415.97 kb
Nombre del archivo: MIO-R2.OperationReferenceGuide.pdf
Idioma del manual:en
Enlace gratuito para este manual disponible en la parte inferior de la página



Resumen del manual


REV Z 7 47 87 127 167 207 42 PLAY A 1 41 81 121 161 201 43 S. FWD Y 6 46 86 126 166 206 44 REW E 5 45 85 125 165 205 45 FWD D 4 44 84 124 164 204 Configuration Mode The configuration mode allows you to set the following device features: .. IR Transmit Mode (38 KHz, 455 KHz or both 38 KHz IR and RF) .. Timeout Adjustment .. Download Mode .. Debug Mode .. Battery Type .. LED Awake Brightness .. LED Sleep Brightness To enter configuration Mode: 1. Press and hold the STOP button and the INPUT button. The two buttons must be pressed within 0.1 seconds of each other and held down for 2 seconds. The device indicates you are now in configuration mode. See below for available modes. 2. Press the EXIT key when you are finished. Your settings will not be lost in the event your batteries die or are removed. IR Transmit Mode Pressing button "1" on the remote toggles the IR transmission mode between 38KHz, 455KHz, RF, and both 38KHz IR and RF. The display indicates the current mode. Timeout Adjustment Press button "2" on the remote to change the sleep timeout from the default. Each time "2" is pressed, the sleep timeout raises incrementally. The pre-determined sleep timeouts are: .. 3 seconds .. 6 seconds .. 9 seconds .. 12 seconds The display indicates the selected sleep timeout. Mio Modero R-2 Programming The Mio R-2 Download Mode Pressing "3" on the remote toggles the Download mode OFF and ON. The Download mode must be ON before you can download a file to the Mio R-2 device. While the Download mode is ON the device will not go to sleep. A power cycle will return the device to Download OFF. Debug Mode Pressing button "4" on the remote toggles development mode between ON and OFF. The display indicates the selected mode. In development mode, the display shows the IR code assigned to buttons when pressed. This mode is useful to the programmer when determining what IR codes are associated to each mode. Battery Type Pressing button "6" on the remote toggles the battery type between Normal and Recharge. The display indicates the selected type. The type of battery in the Mio R-2 dictates the battery type you need to set. LED Awake Brightness Pressing button "7" on the remote toggles the Power LED brightness mode from LOW to MED and then HIGH. The display indicates the selected mode. LED Sleep Mode Brightness Pressing button "8" on the remote toggles the Sleep brightness mode from OFF to LOW and then MED. The Sleep brightness is the state the Mio R-2 assumes while in the charging cradle. TeleText Mode For various reasons, the standard numeric keypad for the Mio R-2 may be bypassed in favor of using the TeleText mode. This mode allows the central toggle wheel to be used to enter alphanumeric information, such as passwords, much like the toggle wheel on a phone. Pressing button "9" puts the central toggle wheel into TeleText mode. Press "9" again to leave TeleText mode. TeleText button functions Toggle Wheel up/down Scrolls character up/down Toggle Wheel left/right Moves cursor left/right between Last button Backspace (moves cursor back one space and erases previous character) Exit button Abort (erases previously selected information without entering it) Enter button Done (submits information) Mio Modero R-2 Programming The Mio R-2 Updating Mio R-2 Firmware Updating firmware in the Mio R-2 is also done through the programming jack. To update the main firmware for the Mio R-2: 1. Connect the Mio R-2 to your computer via the programming jack (FIG. 3). 2. Put the device into Download mode, as shown on page 10. 3. Open NetLinx Studio. 4. Set the Master Communication Settings to Axcess Master and set the baud rate to 115200. 5. Go to Tools > Firmware Transfers > Send to Axcess Device... This opens the Send to Axcess Dialog Window(FIG. 4). FIG. 4 Send to Axcess Dialog Window 6. Browse to the location of the firmware file. 7. Select the file within the Files frame. 8. Click Query for Devices. 9. The Query For Devices field will display a complete list of all devices currently connected to NetLinx Studio capable of accepting the firmware file selected. Select the Mio R-2. In most cases, the Mio R-2 is the only device on the list. 10. Click Send. 11. After device firmware download, check one more time to verify the firmware version change. 12. Click Close. 13. Upon confirmation of a successful send, you can exit NetLinx Studio and disconnect the programming jack. Mio Modero R-2 Programming The Mio R-2 Persistent Serial Commands There are a select number of persistent commands the Mio R-2 recognizes. Establish a HyperTerminal session with your device to use the following commands: Serial Commands @BRT Set Brightness level Syntax: "'BRIT-,'" Variables: brightness level # = a value from 0 - 32. "'@BRT-#'" (Set LED Awake brightness level) "'@BRT-#,#'" (Set LED Awake brightness level, sleep brightness level) Example: (1) "'@BRT-16'" Sets the awake brightness level to 50%. (2) "'@BRT-32,5'" Sets ...


Comentarios



Tu reseña
Tu nombre:
Introduzca dos números de la imagen:
capcha





Categoría