Iniciar sesión:
Votos - 2, Puntuación media: 4 ( )

Manual de usuario Binatone, modelo ACTION 950

Fabricar: Binatone
Tamaño del archivo: 801.19 kb
Nombre del archivo: action-950-user-guide.pdf
Idioma del manual:en
Enlace gratuito para este manual disponible en la parte inferior de la página



Resumen del manual


LCD Screen USER GUIDE PWR/VOL Switch - Rotate clockwise/ counter clockwise to turn the unit ON or OFF, and adjust the volume. \_f Ear/Mic/Charge jack CALL button -Press to send Ringing tone to other PMR units. Transmit (LED) MENU Button -Press to switch between Modes. MIC (Microphone) Receiver (LED) Lights up when you are receiving signals 1 RX SCAN DCS BB mam [ng ¿g On «H* Channel Number. Changes from 1 to 8 as selected by the user. CTCSS Code. Changes from 1 to 38 as selected by the user. Digital Code. Changes from 1 to 83 as selected by the user. Displays the Battery charge level. ¡7HP When the bars are reduced, the battery needs recharging. TX Displayed when transmitting a signal. RX Displayed when receiving a signal. CTCSS Displayed when a CTCSS sub-channel is turned on. DCS Displayed when the Digital Code System is turned On. VOX Displayed when the VOX feature is enabled. SCAN Displays when the PMR is scanning all channels. DCM Displayed when the Dual Watch function is turned ON. On Displayed when the Key Lock feature is activated. A Displays when the call signal is ON. () Displays when the vibrator function is activated. 2. Installation 2.1 Removing the Belt Clip a. Pull the Belt Clip latch up (away from the Action 950) b. While pulling the Belt Clip latch,slide the Belt Clip up as shown in Figurel. 2.2 Installing the Belt Clip a. Slide the Belt Clip into the slot as shown in Figure2. A “click” indicates the Belt Clip is locked into position. 2.3 Installing the Batteries Belt Clip latch Figure 3 Figure 4 Caution: Observe the proper battery polarity orientation when installing batteries. Incorrect positioning can damage both the batteries and the unit. a. Unclip the battery cover latch at the bottom of the cover, and lift the battery cover off. b. Insert the 4 “AAA” size rechargeable batteries by following the +1- polarity marking inside the Battery Compartment as shown in Figure 3. c. Replace the Battery Compartment Cover. See Figure 4. Important Read these Safety Warnings before you charge the batteries. When placing the Action 950 in the charger, use only the power supplies listed in the user instructions supplied with the Action 950. Don’t try to recharge non-rechargeable batteries. Make sure the battery compartment cover is securely locked in place when you are charging the batteries. Dispose of used batteries safely and in a way that will not harm the environment- never try to burn them or put them anywhere they could get burnt or punctured. Don’t leave dead batteries in your Action 950 units. They might leak if you do. 2.4 Charging the Batteries a. Insert the small plug on the end of the mains adaptor into the Power-in Connection Jack at the back of the desktop charger. b. Plug the mains adaptor into a 240V AC, 50Hz main socket with the switch on the socket set to OFF. c. Switch ON the mains socket. Use only the mains adaptor provided. Using any other adaptor will result in non-compliance with EN60950-1 and will invalidate any approvals & warranty. Place the Action 950 units in the charge cradle in an upright position. The Charge LED indicators will light up. It takes about 10 hours to fully recharge the batteries if they are completely run down. New batteries take up to 14 hours to fully charge. Important: Always turn off the PMR units when charging. This will shorten the charging time. Mains socket OR: Charging the batteries (using adaptor) Lift the charge socket cover located on the right side of the handset. Insert the round connector of the 9.0V DC/200mA adaptor into the charge jack. Plug the mains adaptor into a 240V AC, 50Hz main socket with the switch on the socket set to OFF. Use only the mains adaptor provided. Then switch ON the mains socket. Charge jack Battery meter The battery meter is located in the left corner of the LCD Screen. It appears like a battery with three bars inside. These indicate the amount of power available. When the battery level reaches its minimum level in PMR on mode, the unit will emit two beep tones and automatically power off. The Action 950 can detect the battery charge in 4 levels; Battery charge at high level. Battery charge at medium level. Battery charge at low level. At this level, the Action 950 will emit a “beep” sound for every 10 seconds in normal mode. Important: Charge the unit for 10-14 hours. Battery charge at very low level. When the battery level reachs its minimum level in Action 950 on mode, the unit will emit two beep tones and automatically turn off the power . I»D ED EZS uzs Important: Charge the unit for 10-14 hours. CAUTION : Risk of explosion if battery is replaced by an incorrect type. Dispose of used batteries according to the instructions. e. Battery life The Action 950 h as a built in power saver to make the batteries last longer. But when you are not using the units, turn them OFF to conserve battery power. 3. Operation 3.1 Transmitting range ...


Comentarios



Tu reseña
Tu nombre:
Introduzca dos números de la imagen:
capcha





Categoría