Iniciar sesión:
Votos - 3, Puntuación media: 4 ( )

Manual de usuario APC, modelo NETBOTZ NBWL0456

Fabricar: APC
Tamaño del archivo: 753.85 kb
Nombre del archivo:
Idioma del manual:en
Enlace gratuito para este manual disponible en la parte inferior de la página



Resumen del manual


Administrator account user ID and password Your NetBotz appliance has a pre-configured Administrator account. The User ID and Password for this account are: • User ID: apc • Password: apc Note: To increase security, be sure to use the Advanced View Users task to change the default User ID and Password for the Administrator account. Root account user ID and password Your NetBotz appliance has a pre-configured root account. The root account is used only for appliance communications that are performed using the USB Console Port, e.g., when you use the Serial Configuration Utility to specify network settings. The default User ID and Password for this account are: • User ID: root • Password: apc Note: You cannot change the root account User ID. To increase security, use the Advanced View Change Root Password Tool to change the default root account password. NetBotz 455 Installation and Quick Configuration Manual Lost password recovery To recover from a lost password: 1. Locate the reset switch on the bottom of the appliance. 2. Use a thin wire such as a paper clip to press the reset switch for 10 seconds. This causes the system to restart. 3. Once the system restarts, login within two minutes using the default login values: – For Advanced View: • User ID: apc • Password: apc – For the console: • User ID: root • Password: apc Note: If you do not log in within two minutes after holding down the reset switch, you must repeat the procedure. 4. After you log in, change the password to increase security. Basic View Use the Basic View to view the current sensor data, image capture, and other appliance data in a HTML-based interface. Use the Basic View to perform basic appliance configuration. The configuration tasks available from the Basic View are limited and are included for initial appliance installation and setup. This view is provided to allow you to use a Web browser to view appliance status. APC supports the following Web browsers: • Microsoft Internet Explorer® 5.5 and higher (on Windows operating systems only) • Mozilla®-based browsers that support Firefox® 1.x (on all operating systems) • Netscape® 7.x and higher (on all operating systems) Note: Other commonly available browsers also may work but have not been fully tested by APC. NetBotz 455 Installation and Quick Configuration Manual Advanced View Use the Advanced View to view sensor data, camera images, and other appliance data in a custom Java application. You can also use the Advanced View to generate relay output actions and configure all appliance features. The Advanced View is a stand-alone application that must be installed on a supported network-attached computer. For more information on the Basic View or the Advanced View, see the NetBotz Appliance User’s Guide. APC Quick Configuration Once you configure, install, and apply power to your appliance, use the Advanced View to perform the following procedures. • Configure Appliance Settings: Configure the appliance Clock, DNS, Region, Network Interface (hostname, NAT proxy, and speed and duplex settings), E-mail Servers, and Proxy settings. • Configure Alert Actions: Configure the Play Audio Alert and Primary E-mail Notification alert actions. NetBotz 455 Installation and Quick Configuration Manual Configure appliance settings Open the Advanced View and perform the following Appliance Settings tasks. The icons associated with each task are located in the Configuration pane, in the Appliance Settings region. 1. Set the Clock settings. By default, your appliance synchronizes the system clock with the default NTP servers. If network access to these servers is not permitted, double-click on the Clock icon and specify your NTP server address or manually specify clock settings. 2. Set DNS settings. Double-click the DNS icon and specify the DNS Domain and at least one DNS Server address. 3. Set the Region settings. Double-click the Region icon and set Locale and Time Zone. The default settings are US and Central Standard Time. 4. Specify a hostname for your appliance. Double-click on Network Interfaces and specify a hostname for your appliance. Optionally, specify a NAT proxy name or IP address to be used by a NAT Proxy server in your network to allow users to connect to the appliance from outside the firewall. You can also specify speed and duplex settings for use by this interface, or use the default setting, Auto Negotiate. 5. Assign a unique User ID and Password to the Administrator account. By default, User ID and Password for the Administrator account are both apc. To increase security, double-click the Users icon, double-click APC Admin Account, and specify a unique User ID and password for the administrator account. 6. Set your E-mail Server settings. This is the e-mail server that your appliance uses to deliver e-mail alert notifications. Double-click the E-mail Servers icon, and configure the following settings: – (Optional) Provide a From address. –In the SMTP server field, type the hostname or IP...

Otros modelos de este manual:
Baby - NETBOTZ NBWL0455 (753.85 kb)

Comentarios



Tu reseña
Tu nombre:
Introduzca dos números de la imagen:
capcha





Categoría