Iniciar sesión:
Votos - 3, Puntuación media: 5 ( )

Manual de usuario Hitachi, modelo BACKPACK SPRAYER 94573

Fabricar: Hitachi
Tamaño del archivo: 616.1 kb
Nombre del archivo: 94573.pdf
Idioma del manual:en
Enlace gratuito para este manual disponible en la parte inferior de la página



Resumen del manual


Never attempt to spray flammable, combustible, or corrosive liquids with the Sprayer. Always follow all chemical label 6. precautions and local EPA regulations when using liquid chemicals. Do not touch harmful chemicals. After use, clean the Sprayer thoroughly with agents recommended by the chemical manufacturer. Never point the nozzle of the Spray 7. Gun Assembly at yourself, other people, pets and animals, or property. A note on Chemicals disposal: 8. Never attempt to burn unused fertilizers, herbicides, pesticides, or any other types of chemicals. Make sure to check with your local solid waste authorities for proper disposal procedures. Always make sure children and 9. animals do not have access to chemically treated areas. Dry running will cause damage to 10. the inner seals. Make sure the water or liquid chemical supply used for the Sprayer is not dirty or sandy. Do not pull or carry the Sprayer by its 11. Spray Gun Assembly. Use the Handle on the Sprayer to move the tool from one location to another. The work area should have adequate 12. drainage to reduce the possibility of a fall due to slippery surfaces. This product is designed for outdoor 13. use only. Keep the Cap and Spray Gun 14. Assembly of the Sprayer connected to the tool while the system is pressurized. Prior to refilling or emptying the Tank, squeeze the Trigger on the Spray Gun Assembly to completely depressurize the system. Prior to starting the Sprayer in cold 15. weather, check all of the parts of the tool to make sure ice has not formed. Do not store the Sprayer where the temperature will fall below 32° Fahrenheit. Do not keep water or any liquid 16. chemicals in the Sprayer after use. Make sure to clean the Filter of the 17. Sprayer before each use. Never leave the Sprayer unattended.18. When finished using the Sprayer, empty the unit. Thoroughly clean the unit and store it in a clean, dry, safe location out of reach of children. The warnings and cautions discussed 19. in this manual cannot cover all possible conditions and situations that may occur. It must be understood by the operator that common sense and caution are factors which cannot be built into this product, but must be supplied by the operator. People with pacemakers should consult 20. their physician(s) before using this product. Electromagnetic fields in close proximity to a heart pacemaker could cause interference to or failure of the pacemaker. SAVE THESE INSTRUCTIONS Grounding To prevent electric shock and death from incorrect grounding wire connection: Check with a qualified electrician if you are in doubt as to whether the outlet is properly grounded. Do not modify the power cord plug provided with the tool. Never remove the grounding prong from the plug. Do not use the tool if the power cord or plug is damaged. If damaged, have it repaired by a service facility before use. If the plug will not fit the outlet, have a proper outlet installed by a qualified electrician. Double Insulated Tools: Tools with Two Prong Plugs Outlets for 2-Prong Plug Tools marked “Double Insulated” do 1. not require grounding. They have a special double insulation system which satisfies OSHA requirements and complies with the applicable standards of Underwriters Laboratories, Inc., the Canadian Standard Association, and the National Electrical Code. (See Outlets for 2-Prong Plug.) Double insulated tools may be used in 2. either of the 120 volt outlets shown in the preceding illustration. (See Outlets for 2-Prong Plug.) Extension Cords Note: Extension cords must not be used with this item’s charger. Symbology Double Insulated Canadian Standards Association Underwriters Laboratories, Inc. V~ Volts Alternating Current A Amperes n0 xxxx/min. No Load Revolutions per Minute (RPM) SPECIFICATIONS Charger Input 120 V~ / 60 Hz Charger Output 12 VDC Battery Type Rechargeable 12V / 10 Ah Charge Time 8 Hours Charger Cord/Plug 58-1/2” L, 2-Prong Spray Time Output Approximately 9 to 10 Hours (Full Charge) Tank Capacity 4.8 Gallons Flow Rating 0.7 Gallons Per Minute Maximum Pressure 65 PSI Unit Dimensions 7” Long x 15” Wide x 23-5/8” High Spray Rod Dimensions 28” Long x 3/8” Diameter Unit Weight (Empty) 17.5 lb. Accessories Conical Mist Nozzle Four Hole Adjustable Nozzle Mist Nozzle / 30° Dual Nozzle Additional Features Diaphragm Pump Triple Screen Water Filtration UNPACKING When unpacking, make sure all that the item is intact and undamaged. If any parts are missing or broken, please call Harbor Freight Tools at 1-800-444-3353 as soon as possible. Charging Instructions The Battery (51) for the Sprayer must 1. be fully charged before using the tool. When charging for the first time, and all subsequent charges, the charge time is 8 hours. Never charge the Battery (51) for longer than 8 hours, as damage to the Battery and/or Sprayer will occur. CHARGER(63) CHARGINGPLUGPOWER SWITCH(58) FIGURE ECHARGE FOR 8 HOURS(DO NOT OVERCHARGE) 2. To charge the Battery (51), Turn the Power Switch (58) to its “OFF” posit...

Otros modelos de este manual:
Armas - BACKPACK SPRAYER 94573 (616.1 kb)

Comentarios



Tu reseña
Tu nombre:
Introduzca dos números de la imagen:
capcha





Categoría