|
Manual de usuario DeVilbiss, modelo COMPACT P2-11
Fabricar: DeVilbiss Tamaño del archivo: 1.15 mb Nombre del archivo: COMPACT_CONV_S_UserManual.pdf
|
|
|
|
Enlace gratuito para este manual disponible en la parte inferior de la página
Resumen del manual
If there is any doubt regarding the suitability of a specific material contact your local Distributor or ITW Finishing direct. Model Part Number Example: COM-S430-16 Aircap Fluid nozzle size (16 = 1,6 mm) EC Declaration of Conformity We: ITW Finishing UK, Ringwood Rd, Bournemouth, Dorset, BH11 9LH, UK, as the manufacturer of the Spraygun model Compact, declare, under our sole responsibility, that the equipment to which this document relates is in conformity with the following standards or other normative documents: BS EN 292-1 PARTS 1 & 2: 1991, BS EN 1953: 1999; and thereby conform to the protection requirements of Council Directive 98/37/EC relating to Machinery Safety Directive, and; EN 13463-1:2001, council Directive 94/9/EC relating to Equipment and Protective Systems intended for use in Potentially Explosive Atmospheres protection level II 2 G X. B. Holt, General Manager 30th June 2003 ITW Finishing Systems and Products reserve the right to modify equipment specification without prior notice. © 2005 ITW Finishing Systems and Products 2 SAFETY WARNINGS E EE sprayed. Fire and explosion Solvents and coating materials can be highly flammable or Always wear eye protection when combustible when sprayed. ALWAYS spraying or cleaning the spraygun refer to the coating material suppliers Gloves must be worn when instructions and COSHH sheets spraying or cleaning the equipment before using this equipment Training – Personnel should be givenUsers must comply with all local adequate training in the safe use of and national codes of practice spraying equipment. and insurance company requirements governing Misuse ventilation, fire precautions, operation Never aim a spraygun at any part of theand house-keeping of working body areas Never exceed the max. recommended This equipment, as supplied, safe working pressure for the equipment is NOT suitable for use with The fitting of non-recommended or non- Halogenated Hydrocarbons. original spares may create hazards Static Electricity can be Before cleaning or maintenance, all generated by fluid and/or air pressure must be isolated and relieved passing through hoses, by the spraying from the equipment process and by cleaning non- conductive The product should be cleaned using a parts with cloths. To prevent ignition gun washing machine. However, this sources from static discharges, earth equipment should not be left inside gun continuity must be maintained to the washing machines for prolonged periods spraygun and other metallic equipment of time. used. It is essential to use conductive air and/or fluid hoses. Noise Levels Personal Protective The A-weighted sound level of sprayguns may exceed 85 dB Equipment (A) depending on the set-up being used. Toxic vapours – When Details of actual noise levels are sprayed, certain materials may available on request. It is recommended be poisonous, create irritation that ear protection is worn at all times or be otherwise harmful to health. when spraying. Always read all labels and safety data sheets for the material before spraying Operating and follow any recommendations. Spray Equipment using high pressures If In Doubt, Contact Your may be subject to recoil forces. Under Material Supplier certain circumstances, such forces could The use of respiratory protective result in repetitive strain injury to the equipment is recommended at all times. operator. The type of equipment must be compatible with the material being 3 © 2005 ITW Finishing Systems and Products E EE Parts List Ref. No Description Part Number Qty Options 1 Air Cap/Retaining ring SP-100-430-K 1 + 2 Nozzle SP-200S-**-K 1 16,18,20,22 e.g ** =16 =1.6 mm + 3 Separator SP-623-K5 5 + 4 Packing GTI-445-K2 2 Spreader Valve SP-401-K 1 6 Stud and Screw GTI-408-K5 5 7 Needle Adjusting Screw SP-614-K 1 + 8 Spring SP-622-K5 1 + 9 Needle SP-300S-**-K 1 16,18,20,22 e.g ** =16 =1.6mm Airvalve housing + seal SP-612-K 1 + 11 Spindle -1 12 Trigger SP-617-K 1 13 Connector SP-611-K 1 14 Airflow Valve SP-402-K 1 Fluid Inlet Connector and seal SP-610–K 1 + 16 Air Valve Service Kit SPK-101-K 1 17 RetainingRing and Seals SPK-102-K 1 + 18 Spreader/ Cheater Service Kit GTI-428-K5 5 19 Circlip 25746-007-K5 5 Washer - kit of 5 KS-48-K5 2 21 Cam KR-445-1 1 22 Washer - kit of 5 KR-40-K5 1 23 Lid Gasket - kit of 3 KR-11-K3 1 24 Nut - kit of 5 KR-94-K5 1 Drip free diaphragm—kit of 5 KR-115-K5 1 26 Cup KR-466-K 1 27 Cup lid assembly KR-4001-B 1 28 Cup -KR-566-1-B 1 29 Yoke KR-77-1 1 Fluid Tube KR-456-B 1 + 31 Air valve Assembly Tool 1 32 Spanner SPN-5 1 Spraygun Service Kit (parts included marked + ) SPK-401-** 1 16,18,20,22 e.g ** =16 =1.6 mm © 2005 ITW Finishing Systems and Products 4 EE EE Patent No 2372465 (GB) Specification Air supply connection Universal 1/4“ BSP and NPS Fluid Supply Connection -Universal 3/8“ BSP and NPS Maximum static Air inlet pressure -P1 = 12 bar (175 psi) Maximum static Fluid inlet pressure -P2 = 15 bar (218 psi) Nominal gun Air inlet pressure - with gun triggered 3.0 bar (44 p...
|