Iniciar sesión:
Votos - 4, Puntuación media: 4.5 ( )

Manual de usuario Casio, modelo DQR-200U

Fabricar: Casio
Tamaño del archivo: 790.3 kb
Nombre del archivo: DQR200U.pdf
Idioma del manual:en
Enlace gratuito para este manual disponible en la parte inferior de la página



Resumen del manual


Be sure to remove the sticker before using the clock. • Depending on the clock model, the configuration of your clock may differ somewhat from that shown in the illustration. Alarm Off Alarm On • In locations subject to radio frequency interference, the product may malfunction and require you to reset the product. MA0402-EB UP (+) SET SNZ ON OFF ALM RESET °C/ °F RE-SYNC WAVE TEMP. MAX/MIN CLEAR DOWN (—) UP (+) SET RESET °C/ °F RE-SYNC WAVE TEMP. MAX/MIN CLEAR DOWN (—) SNZ ON OFF ALM 1 4 3 78 2 5 9 6 0 Main unit °C/ °F RESET °C/ °F RESET A C B Sub-unit Alarm on PM indicator indicator Wave OK indicator Antenna Icon Current Temperature (OUTDOOR) Upcomimg weather indicator Current time (Hour, minutes, seconds) Day of the week DATE (month – date) Current Temperature (INDOOR) Snooze on indicator Alarm time Operation Guide DQR-200U 2 GENERAL GUIDE Main unit 1SNOOZE/LIGHT button •Press this button to illuminate the display for about four seconds. •Pressing this button while the alarm is sounding stops the alarm. 2Alarm Time Set buttons Use these buttons to change the alarm time or current time setting. 3SET button Use this button when setting the current time. 4WAVE button Press this button to receive the time calibration signal and adjust timekeeping. 5Alarm Mode selector SNZ: Snooze alarm on ON: Alarm on OFF: Alarm off 6RESET button Press this button to reset the clock after replacing its batteries. 7MAX/MIN TEMP. button Press this button to display the high and low temperature values. 8CLEAR button Press this button to clear the currently displayed high/low temperature. 9°C/ °F button Press this button to toggle the temperature units between Celsius and Fahrenheit. 0RE-SYNC button Press this button to re-synchronize the timing of the main unit and the sub-unit. Sub-unit A°C/ °F button Press this button to toggle the temperature units between Celsius and Fahrenheit. BRESET button Press this button to reset the sub-unit after replacing its batteries. CTEST button This button is for testing the unit. Normally, you should not press it. If you do, be sure to press the RESET button (B) next. TIME CALIBRATION SIGNAL RECEPTION PRECAUTIONS •This clock is able to receive the time calibration signal transmitted from Rugby, England. Signal reception is possible within approximately 1,000 km of the transmitter. •Even when the clock is within the reception range, signal reception is impossible if the signal is blocked by mountains or other geological formations between the clock and signal source. •Signal reception is affected by weather, atmospheric conditions, and seasonal changes. •The time calibration signal is bounced off the ionosphere. Because of this, such factors as changes in the reflectivity of the ionosphere, as well as movement of the ionosphere to higher altitudes due to seasonal atmosaheric changes or the time of day may change the reception range of the signal and make reception temporarily impossible. •Reception is best when the back of the clock is facing toward Rugby. Note, however, that moving the clock while the time calibration signal receive operation is taking place will make stable reception impossible. •Think of the clock as acting like a TV or radio when it is receiving the calibration signal.When receiving indoors, move to a location as near as possible to a window. Proper signal reception can be difficult or even impossible under the conditions listed below. Rugby1,000 kilometers 500 kilometers Inside, among buildings, or near neon signs Inside a vehicle Near refrigerators or other household appliances, near office equipment, mobile phones or wireless LAN devices. Near a construction site, airport, or other sources of electrical noise, underground or in tunnels, near railroads, highways, or radio stations with interfering frequencies. Near high-tension power lines Among or behind mountains •Signal reception is normally better at night than during the day. •Radio interference can make signal reception impossible. •Strong electrostatic charge can result in the wrong time being set. •The alarm does not operate during signal reception. Operation Guide DQR-200U 2 GENERAL GUIDE Main unit 1SNOOZE/LIGHT button •Press this button to illuminate the display for about four seconds. •Pressing this button while the alarm is sounding stops the alarm. 2Alarm Time Set buttons Use these buttons to change the alarm time or current time setting. 3SET button Use this button when setting the current time. 4WAVE button Press this button to receive the time calibration signal and adjust timekeeping. 5Alarm Mode selector SNZ: Snooze alarm on ON: Alarm on OFF: Alarm off 6RESET button Press this button to reset the clock after replacing its batteries. 7MAX/MIN TEMP. button Press this button to display the high and low temperature values. 8CLEAR button Press this button to clear the currently displayed high/low temperature. 9°C/ °F button Press this button to toggle the temperature units between Celsius and Fahrenheit. 0RE-S...


Comentarios



Tu reseña
Tu nombre:
Introduzca dos números de la imagen:
capcha





Categoría