See “REF Level Setting”. 3. On the AD converter, select output channels: 1-4 or 5-8: after entering the SHIFT operation mode if 88.2 or 96 kHz is used. The selected channel outputs will be recorded on the ADAT's tracks: output channels “1, 2, 3 and 4” or “5, 6, 7 and 8” will be recorded onto track 1/2, 3/4, 5/6 and 7/8 respectively. (1) To enter the SHIFT operation mode press the WORD LENGTH button for 2 second or more. (2) Press the FREQ button to select output channels. The FREQ LEDs indicate the selection. CH 1-4: The FREQ LED 44.lk/88.2k lights. CH 5-8: The FREQ LED 48k/96k lights. 4. On the BRC, select “48 k Input" by pressing the EXT SYNC switch to sync to the wordclock. 34 5. On the ADAT’s front panel, press the DIGITAL IN switch to receive digital audio input. Legend j CLOCK: — -► ; AUDIO: -► j Key Board WZ-AD96/AD96M iD*I0lIT j WZ-AD96/AD96M Setting i »CLOCK: CRYSTAL ; • REF LEVEL: -16 dBFS ! • WORD CLOCK-OUT: OUT WZ-DA96 W2-DA96 Setting ■ CLOCK: EXT SP Optical Cable Optical Cable SP BRC Setting : « EXT SYNC: 48k INPUT '• OKjfTAL IN t OUT j □ □□□a □ ADAT : ADAT Setting CLOCK SELECT: EXT(AUTO) INPUT SELECT: DIGITAL Connection-2 Connecting the System Connecting wth TDRS (Connection 3) Wordclock master: WZ-AD96/96M AD Converter • Connection 1. Install the TDIF card, an option to the AD converter, into the rear slot. See instructions attached to the card for more details. 2. Connect between Wordclock-Out on the AD converter and WCK IN on the DA converter with a BNC cable. In addition connect WCK THRU on the DA converter and WORD SYNC In on the DA88 converter with a BNC cable. Note that inside the AD converter both CN907 and 908 jumpers are set to “OUT” positions. 3. Connect TDIF Out on the AD converter and TDIF In on the DA88 with a DB25 Y cable as illustrated. In addition connect one end of the DB25 Y cable to the TDIF In on the DA converter to monitor the sound. See page 40 for detailed information on DB25 Y cable. • Setting 1. On the AD converter, select “CRYSTAL” by pressing the CLOCK button, then select a sampling rate by pressing the FREQ button. Note that if 88.2 or 96 kHz is selected , move the DIP switch #6 to On to keep sending 44.1 or 48 kHz wordclock to the DA88. 2. Set the DIP switch on the AD converter #7 to Off and #8 to On to meet the REF level to -16 dBFS. See “REF Level Setting”. 3. On the DA88, select “WORD” by pressing the CLOCK switch to let it sync to the wordclock. 4. On the AD converter, select output channels: 1-4 or 5-8: after entering the SHIFT operation mode if 88.2 or 96 kHz is used. The selected channel outputs will be recorded on the DA88’s tracks: output channels “1, 2, 3 and 4” or “5, 6, 7 and 8” will be recorded onto track 1/2, 3/4, 5/6 and 7/8 respectively. (1) To enter the SHIFT operation mode press the WORD LENGTH button for 2 second or more. (2) Press the FREQ button to select output channels. The FREQ LEDs indicate the selection. CH 1-4: The FREQ LED 44.1k/88.2k lights. CH 5-8: The FREQ LED 48k/96k lights. 5. On the DA88's front panel, press the DIGITAL IN switch to receive digital audio input. 36 Chapter 5 Legend : CLOCK:---► i AUDIO: ■ ■■ » i Key Board wofoaocK TK«WOUT) W2-AD96/AD96M WZ-AD96/AD96M Setting • CLOCK: CRYSTAL • REF LEVEL:-16 dBFS • WORD CLOCK-OUT: OUT WOOD CLOCK IN TOF rj 25 p :::r[; p.-n. THRU W2-DA96 WZ-DA96 Setting • CLOCK: EXT SP SP E OA86 DA88 Setting •MACHINE ID: 0 • CLOCK: WORD • INPUT: DIGITAL • OIGITAL IN: ON Connection-3 37 Connecting the System Connecting with Pro Tools (Connection 4) Wordclock master: Pro Tools 888 I/O • Connection 1. Connect SLAVE CLOCK OUT on the 888 I/O #1 and SLAVE CLOCK IN on the 888 I/O #2 with a BNC cable. Then connect between #2 and #3 in the same way as #1 and #2. 2. Connect SLAVE CLOCK OUT on the 888 I/O #3 to WCK In on the DA converter with a BNC cable. 3. Connect WCK Out on the DA converter and WCK In on the AD converter #1 with a BNC cable. Then, connect between Wordclock-Out on the AD converter #1 and Wordclock-In on the AD converter #2 with a BNC cable. In the same manner connect the AD converter #2, #3 and the DA converter with BNC cables. 4. Connect AES/EBU Out on the AD converter #1 and AES/EBU In on the 888 I/O #1 with XLR cables. For #2 and #3 connect in the same manner. 5. Connect between the AES/EBU Out on the 888 I/O #1 and AES/EBU In on the DA converter with XLR cables to monitor the sound. • Setting 1. Set SYNC MODE to “INTERNAL”, and select SAMPLE RATE from 44.1k or 48k on the 888 I/O #1. 2. Set Channel 1-8 INPUT to “DIGITAL”, and 1-2 FORMAT to “AES/EBU ”on the 888 I/O #1-3. 3. On the AD converter select “EXT” by pressing the CLOCK button, and set the DIP switch #7 to On and #8 to Off to meet the REF level to -18 dBFS. See “REF Level Setting”. 38 Chapter 5 Legend CLOCK: — AUDIO: » Connection-4 39 Chapter 6 Technical Specifications General Power requirement Power consumption Dimensions (mm) (inch) ...