|
Manual de usuario Bradley Smoker, modelo AERADA 1100 SERIES 1100
Fabricar: Bradley Smoker Tamaño del archivo: 609.28 kb Nombre del archivo: fa1558.pdf
Idioma del manual:
|
|
|
|
Enlace gratuito para este manual disponible en la parte inferior de la página
Resumen del manual
Read this entire installation manual to ensure proper installation, then file theseinstructions with the owner or maintenance department. Flush all the water supply lines before making connections, then make sure the watersupply is turned off before beginning installation. Do not use pipe dope on faucet and supply connections. Possible solenoid contaminationcould occur and will void any warranty. Teflon tape is the recommended sealant. The installation site should have access to an electrical box with 120 volt AC, 60 Hz cyclefor input to a transformer. When installing the transformer, the electrical box should belocated within six feet of the sink. The DC faucet is powered by one factory-installed 6-volt lithium battery. Pressurized plumbing fixtures must be installed in accordance with manufacturer’srecommendations. The supply piping to these devices must be securely anchored to thebuilding structure to prevent the installed device from unnecessary movement whenoperated by the user. Use extreme caution when installing the device to prevent damage tothe exposed significant surface. Compliance and conformity to local codes and ordinances is the responsibility of theinstaller. Product warranties may be found under “Product Information” on our web site at215-1558 Rev. A; EN 07-202 P.O. Box 309, Menomonee Falls, WI 53052-0309 © 2007 Bradley Corporation Phone: 1-800-BRADLEY FAX: (262) 251-5817 Page 1 of 8 3/8/07 Aerada 1100 Series High Arc Faucet Installation Instructions Table of Contents Faucet Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2 Supplies Required for Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2Faucet Components . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3 Installation Information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4 Cleaning and Maintenance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5 Changing the Battery . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .6Changing the Sensor Detection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .6Faucet Troubleshooting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .7 Transformer Connection Detail . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .8 4.8" (122mm) 5.3" (135mm) 7.6" (193mm) 0.2"-1.2" 14" (356mm) 0.9" (23mm) G 3/8" (10mm) SW 0.75" (19mm) SW 1.5" (38mm) 25° Faucet Dimensions Supplies Required for Installation: • Teflon Tape • 1/2" NPT water inlet supply • Pipe fittings 3/8/07 Bradley Corporation • 215-1558 Rev. A; EN 07-202 3 Installation Instructions Aerada 1100 Series High Arc Faucet Bradley Corporation • 215-1558 Rev. A; EN 07-202 3/8/07 Components for Aerada 1100 Series Faucet Model S53-305 shown, model S53-304 is similar Carefully separate all parts from packaging and check each part with the illustrations below. Make sure all parts are accounted for before discarding any packaging material. If any parts are missing, do not attempt to install your Bradley Faucet until you obtain the missing parts. VANDAL-RESISTANT AERATOR (S05-176) O-RING FIXING SCREW WITH WIRE AC ADAPTER MODULE (AC model only) SOLENOID VALVE (269-1806) ELECTRONIC MODULE (269-1807) BRAIDED SUPPLY HOSE SCREEN FILTER ADAPTER FOR ANGLE STOP VALVE BACKFLOW PREVENTER AND FILTER BRAIDED SUPPLY HOSE SETSCREW EXTERNAL TEMPERATURE CONTROL KNOB 115V AC PLUG-IN ADAPTER (232-006) Aerada 1100 Series High Arc Faucet Installation Instructions 1. Turn off water supply to the existing faucet and remove the faucet. 2. Mount the spout and rubber washer to top of base as shown in the illustration. Install the second rubber washer, steel washer and spout nut underneath the base. Securely tighten the spout nut. 3. Tighten the spout nut securely to prevent the spout from rotating. If necessary, support the spout from above to prevent twisting. Do not overtighten. IMPORTANT: Do not use a wrench on spout or inlet tubes. 4. AC Only: Plug the power supply into the appropriate 110/115V wall outlet. Connect the power supply female plug into the faucet male plug. NOTE: Power supply is equipped with an 11.8" (30cm) cord. For multiple faucet installation, an additional extension cord is provided. Refer to the wiring diagram packaged with the faucet. 5. Connect the hot and cold water lines to the supply pipes. Use Teflon tape on the threads to ensure a leak-free joint. Tighten connections securely. 6. Turn the water supply on. 7. Remove the protective covering from the sensor. 8. Place a hand in front of the sensor for 15 seconds to activate for the first time. Installation Instructions AC High Arc Faucet shown; DC model is similar. RUBBER WASHER SPOUT RUBBER WASHER, STEEL WASHER, SPOUT NUT HOT AND COLD WATER SUPPLY 3/8/07 Bradley Corporation • 215-1558 Rev. A; EN 07-202 5 Installation Instructions Aerad...
|