|
Resumen del manual
. 17 For best results, Hansgrohe recommends that this unit be installed by a licensed, professional plumber. Please read over these instructions thoroughly before beginning installation. Make sure that you have all tools and supplies needed to complete the installation. This product is listed by IAPMO and is approved for use in Massachusetts. • • • Protection against backflow provided by check valve in the handshower outlet. The high temperature limit stop on the thermostatic mixing valve may be reset to comply with local plumbing codes* -- see page 13. • • *In Massachusetts, the maximum output temperature cannot exceed 112°F. English Rough-in This unit can be installed on a flat wall or in a 90° corner. Instructions for installation on a flat wall begin on page 5. Go to page 8 if the panel is to be installed in a corner. Ensure that you have a minimum 83" ceiling height from the standing surface. Stub out 1/2" NPT male nipples for the hot and cold water supplies at the locations shown on the appropriate rough-in Installation on a flat wall diagram. The nipples should extend 5/8" outside the surface of the finished wall. Install the wall surface and make the wall watertight before installing the panel. The panel hangs on the finished wall. Seal the wall around the nipples with waterproof sealant. Failure to seal the wall can lead to possible water damage. Installation in 90° corner Installation .. flat wall Wrap the threads on the nipples with Teflon tape. Install the elbows so that the outlets face upwards. Measure up the wall 78 .", making sure that the line is plumb. Mark the position for the top screw hole. From the position of the top screw hole, measure down 35 3/8”. Mark the position for the center screw hole. From the center screw hole, measure down 19 1/8". Mark the position for the bottom screw hole. Use a 6 mm bit to drill the three screw holes. Install the set screws in the top and bottom holes. Use a 10 mm nut driver to attach a nut to the top set screw. Slide the panel over the top and bottom set screws. Tighten the nut on the top set screw. Install and tighten the nut on the bottom set screw. Install one recessed head screw and the large washer on the center hole. Tighten the screw. Seal the wall around the anchors with waterproof sealant. Failure to seal the wall can lead to possible water damage. English Use the compression nuts and ferrules to connect the supply hoses on the panel to the supply elbows. Use two wrenches, as shown, to prevent the supply hoses from twisting. Attach the seals to the side covers. Install the side covers. The pins on the covers must go into the grooves on the sides of the panel. English Push the bodyjet supply hose on the valve cover into the fitting on the panel. Install the valve cover on the panel. The pins on the cover must connect to the slots on the panel. Turn to page 11 to continue the installation. English English Installation in 90° corner Wrap the threads on the nipples with Teflon tape. In...
Otros modelos de este manual:Fontanería - Metro E 0657000 (5.13 mb)
Fontanería - Metro E 0657000 (5.13 mb)
Fontanería - Metro E 06573000 (5.13 mb)
Fontanería - Metro E 06573000 (5.13 mb)