Iniciar sesión:
Votos - 4, Puntuación media: 3.8 ( )

Manual de usuario Delta, modelo TOWNSQUARE 2555.602

Fabricar: Delta
Tamaño del archivo: 227.87 kb
Nombre del archivo: Install_1275.pdf
Idioma del manual:en
Enlace gratuito para este manual disponible en la parte inferior de la página



Resumen del manual


1 7-1/2" OPTIONAL TO FINISHED FLOOR USUALLY BETWEEN 65'' AND 78'' 8" REF. 7-1/4" REF. 4" 1/2" COPPER 1-3/4" REF. 18" OPTIONAL "SEE ILLUSTRATION" TOP OF TUB RIM SHW TUB M968789 Rev. 1.5 Thank you for selecting American-Standard...the benchmark of fine quality for over 100 years. To ensure that your installation proceeds smoothly--please read these instructions carefully before you begin. 3 INSTALL TRIM Push CAP (1) over VALVE CARTRIDGE (2). Mount ESCUTCHEON (3) and gasket to valve body with SCREWS (4). Remove PIPE CAPS (5) from shower pipe and tub filler pipe. Install SHOWER ARM (6) and SHOWER HEAD (7). Install SLIP-ON TUB SPOUT (8). Tighten with HEX WRENCH supplied. 2 INSTALL DIVERTER When finished tiling the wall, remove PLASTER GUARD (1). Remove two screws that secure the DIVERTER LID (2) and remove Lid. Inspect the inside surface of diverter port. Diverter port must be free of any dirt. Clean if necessary. Install DIVERTER (3) with SCREWS (4) removed from DIVERTER LID (2). Operate DIVERTER (3). DIVERTER (3) should slide in and out smoothly. Push on DIVERTER COVER (5). 1 2 4 5 3 DIVERTER PORT ADJUST HOT LIMIT STOP By restricting HANDLE rotation and limiting the amount of hot water allowed to mix with the cold, the HOT LIMIT SAFETY STOP (1) reduces risk of accidentalscalding. To set the maximum hot water temperature of your faucet, all you need to do is adjust the setting on the HOT LIMIT SAFETY STOP (1). 4 Turn CARTRIDGE STEM (2) to the OFF position (coldest setting) before making adjustment to HOT LIMIT STOP (1). Use a flat blade screwdriver to pry free the HOT LIMIT SAFETY STOP (1). Pull forward and rotate counterclockwise one number to limit hot water temperature. Use ARROW (3) on CARTRIDGE (4) and NUMBERS (5) on HOT LIMIT STOP (1) for indication. 151311975310 15131197531 15131197531 COLDER (Larger Numbers) 0 1 3 5 7 9 11 13 15 HOTTER (Smaller Numbers) 0 1 3 5 7 9 11 13 15 1 5 1 5 4 4 3 3 2 2 6 7 3 1 4 5 2 5 8 CAUTION: Protect finish on SHOWER ARM and SHOWER HEAD when installing. HEX WRENCH 1-3/4" REF. M968789 Rev. 1.5 5 INSTALL HANDLE Install HANDLE BUSHING (1) onto CAP (2). Find correct position of HANDLE (3) and push HANDLE (3) onto VALVE STEM (4). Install HANDLE SCREW (5) and push in INDEX CAP (6). Check proper operation of HANDLE. 5 6 Screw on DIVERTER KNOB (7). 1 3 24 7 6 TO GAIN ACCESS TO VALVE FOR SERVICING Pull INDEX CAP, unscrew HANDLE SCREW and pull HANDLE off valve stem. Remove two SCREWS holding ESCUTCHEON and remove ESCUTCHEON. Remove COVER by pulling straight out. Shut off water supply by either closing off main water supply, or closing off the hot and cold CHECK STOPS on valve, if present. VALVE LEAKS WHEN SHUT OFF Remove CARTRIDGE (1) by removing CARTRIDGE SCREWS (2). Remove three SCREWS (3) from FIXATION RING (4) and pull out PRESSURE BALANCING (5) unit. Clean SEALS (9) on base of CARTRIDGE (1). Check base of PRESSURE BALANCING UNIT (5) and clean O-RINGS (6). Remove CAPS (7) and check O-RINGS on inside of CAPS (7). Clean in...

Otros modelos de este manual:
Fontanería - TOWNSQUARE 2555.602 (227.87 kb)
Fontanería - TOWNSQUARE 2555.602 (227.87 kb)
Fontanería - TOWNSQUARE 2555.602 (227.87 kb)

Comentarios



Tu reseña
Tu nombre:
Introduzca dos números de la imagen:
capcha





Categoría