Iniciar sesión:
Votos - 4, Puntuación media: 3.5 ( )

Manual de usuario American Standard, modelo 641

Fabricar: American Standard
Tamaño del archivo: 226.72 kb
Nombre del archivo:
Idioma del manual:en
Enlace gratuito para este manual disponible en la parte inferior de la página



Resumen del manual


Shut-Off Valves Connect supply line to faucet (finger tight) and carefully bend tubes to engage with the supply shut-off valves. Tighten connections at faucet and shut-off valves for secure seal. B C Connect trap to drain assembly hand tight to check alignment. It may be necessary to cut off part of the tailpiece (area “B”) or part of the horizontal leg of the trap (area “C”). Secure joints for watertight assembly. 7301354-100 Rev. B 3 3. Above Counter OR 4. Drop-in ** BACK OF LAVATORY IS UNGLAZED ** The lavatory must be installed flush with wall. Countertop Installation: Using the template provided, locate the position of the sink on the countertop. Provide proper clearance under the countertop for the faucet supply lines, drain assembly and the structural parts of the cabinet. NOTE: If replacing an existing sink be certain to shut off water supply before removing old sink. 3-A 4-A After checking fit and alignment, turn sink upside down and apply a generous portion of silicone adhesive around the under side of the rim near the edge. Place sink in position. Wipe off excess adhesive. 3-E 4-E Drill a clearance hole inside the perimeter line of the template for countertop installation. Cut opening around the perimeter of the template. Perimeter of template Perimeter of template 3-B 4-B Mount the faucet and drain assembly (not included) on the sink following the manufacturer’s instructions. Be certain to apply a bead of sealing putty on the underside of the drain (Part “A”) in order to ensure a watertight seal between the sink and drain. Remove excess putty after installing drain on sink. A 3-C 4-C Use the mounting holes on the rear of the lavatory to secure the sink to the wall. 3-F 4-F Connect supply line to faucet (finger tight) and carefully bend tubes to engage with the supply shut-off valves. Tighten connections at faucet and shut-off valves for secure seal. 3-G 4-G Shut-Off Valves 3-D 4-D B C Connect trap to drain assembly hand tight to check alignment. It may be necessary to cut off part of the tailpiece (area “B”) or part of the horizontal leg of the trap (area “C”). Secure joints for watertight assembly. 3-H 4-H Countertop Installation: • Place the sink temporarily into the template • Check for alignment and clearance • Mark the sink and countertop in several places as a guide for the installation location. Part #REPAIR PARTS LIST Description 047523-0070A Wall mounting kit 7301354-100 Rev. B 4 ...

Otros modelos de este manual:
Fontanería - 404 (226.72 kb)
Fontanería - 403 (226.72 kb)

Comentarios



Tu reseña
Tu nombre:
Introduzca dos números de la imagen:
capcha





Categoría