Insert the flush valve sensor wire connector into the CENTER CIRCUIT BOARD RECEPTOR (6) on each unit. Fig. 15a. 4. Remove the SPLIT PLUG (7a) from the SENSOR WIRE GROMMET (7) on the left side of each ELECTRICAL BOX (3). 5. Take the 10 ft. EXTENSION WIRE (8) from Unit #2 and insert one end of the EXTENSION WIRE CONNECTOR (9) through the SENSOR WIRE GROMMET (7) on left side of Unit #1. Insert EXTENSION WIRE (8) into SPLIT PLUG (7a). Push SPLIT PLUG (7a) into SENSOR WIRE GROMMET (7) to seal. Insert EXTENSION WIRE CONNECTOR (9) into LOWER CIRCUIT BOARD RECEPTOR (10). Fig. 15a. 6. Insert other end of EXTENSION WIRE (8) into SENSOR WIRE GROMMET (7) on left side of Unit #2. Insert that EXTENSION WIRE CONNECTOR (9) into the LOWER CIRCUIT BOARD RECEPTOR (10) of Unit #2. Fig. 15b. 7. On Unit #2 ELECTRICAL BOX (3) remove ROUND KNOCK-OUT (11) on the bottom of the box by pressing a flathead screwdriver into the center of the ROUND KNOCK-OUT (11). Fig 15b. 8. Insert additional SENSOR WIRE GROMMET (12) included with Unit #2 into the knock-out opening in the bottom of the ELECTRICAL BOX (3). Take the 10 FT. EXTENSION WIRE (8) from Unit #3 and insert one end into the SENSOR WIRE GROMMET (12) in the bottom of the ELECTRICAL BOX (3) of Unit #2. Insert EXTENSION WIRE CONNECTOR (9a) into TOP CIRCUIT BOARD RECEPTOR (13) on Unit #2 . Fig. 15b. 9. Insert the other end of the EXTENSION WIRE (8) from Unit #3 into the SENSOR WIRE GROMMET (7) on the left side of Unit #3. Insert EXTENSION WIRE CONNECTOR (9) into LOWER CIRCUIT BOARD RECEPTOR (10) on Unit #3. 10. Repeat Steps 7 to 9 as necessary for additional Multi-AC Units. 11. Once all wire connections are made. Install the COVER (2) and COVER SCREWS (1) onto each ELECTRICAL BOX (3). Fig. 15 Fig. 15a Fig. 15b 12 9 TOP TOP TOP 2 7a 7 8 3 6 1 5 4 9 TOP 10 SENSOR WIRE CONNECTOR SENSOR WIRE FROM UNIT #2 Unit #2 7a 7 8 3 9a TOP 12 7 12 8 8 8 8 12 11 10 9 SENSOR WIRE CONNECTOR FROM UNIT #3 BACK OF BOX (3) FROM UNIT #1 REMOVE KNOCK-OUT (11), INSERT WIRE GROMMET (12) 1 2 SENSOR WIRE SENSOR WIRE 6 10 7 6 10 13 7 6 10 13 13 M968550 REV. 1.6 13 HOWTO INSTALL NEW BATTERY; Fig. 16 1. Remove FRONT PANEL. For removing front panel see Step 9 for instructions. 2. Remove the four COVER SCREWS (1) and COVER (2) from ELECTRICAL BOX (3). Fig. 16. 3. Disconnect GREY SENSOR WIRE (4) from CIRCUIT BOARD (5). 4. Remove CIRCUIT BOARD (5) from ELECTRICAL BOX (3). Fig. 16a. 5. With your thumbs, spread the two TABS (6) on battery holder apart and remove the BATTERY (7). 2. Install NEW BATTERY (7) into holder on DC circuit board. Press BATTERY (7) down (contacts facing downward) into position until TABS (6) lock BATTERY (7) into place. 6. Install CUIRCUIT BOARD (5) and connect GREY SENSOR WIRE (4). 7. Install COVER (2) and SCREWS (1). 8. Replace and FRONT PANEL. See Step 9 for instructions on installing front panel. 14 ADJUST SUPPLY STOP; Fig. 17 IMPORTANT: To avoid overflowing, the SUPPLY STOP (2) must never be opened to the point where the flow from th...
Otros modelos de este manual:Fontanería - SELECTRONIC 6065.22X (869.21 kb)
Fontanería - SELECTRONIC 6065.26X (869.21 kb)
Fontanería - SELECTRONIC 6068.22X (869.21 kb)
Fontanería - SELECTRONIC 6068.26X (869.21 kb)