|
Resumen del manual
If the power source is out of sight, lock and TAG IN OPEN (OFF) POSITION to prevent unexpected power application. Failure to do so could result in fatal electrical shock! This unit is not designed for use in septic tanks or underground vaults to pump raw sewage or effluents. Never use in hazardous or explosive locations. 1. This pump has been designed to attach to a standard garden hose. Thread the female end of the garden hose to the male discharge on the pump. 2. To reduce leakage between the pump and the hose, place a hose washer (not included) on the garden hose before installing to the pump. 3. For best pump performance, unwind the hose before starting the pump. This will help remove any kinks or binds in the hose and allow the unit to pump with less restriction. 4. Set the pump on a hard surface in the water. Do not set the pump directly on mud or sand surfaces. This will cause the inlet screen to clog. 5. The water level must be at least 1/2 inches for the pump to operate. Water levels less than 1/2 inches will not allow the impeller to contact water and no water will be pumped. © 2000 Wayne Water Systems 351301-001 1/00 Operating Instructions and Parts Manual Installation and Operation (Continued) Do not handle pump with wet hands or when standing in water or on a damp surface when the unit is operating or fails to operate. Always disconnect pump power cord from power source before handling. 6. Plug the power cord into a grounded 115-volt AC power outlet. The pump will start operating as soon as the power cord is plugged into the power outlet. 7. The pump will remove water down to 1/8 inches of the hard surface the pump was placed on. 8. The pump should be turned off once the water level reaches the 1/8-inch mark. Do not allow pump to run dry. The shaft seal depends on water for lubrication. Operating pump without water will damage the shaft seal and cause pump failure. Maintenance Always disconnect electric supply before attempting to install, service, relocate or perform any maintenance. Failure to do so could result in fatal electrical shock. Minimal service is required for this pump. If pump should fail to operate, perform the following troubleshooting guidelines: operate, unplug power cord and proceed to maintenance guideline item 4 in this section. 3. Verify discharge hose is correctly installed. a. Connect hose to another water source such as a faucet. If water flows through hose, proceed to step 3b. If water is restricted, verify discharge hose is unwound. Remove all kinks, bends or obstructions in hose. b. Verify pumping height does NOT exceed 25 feet (See Figure 1). If pumping height is greater than 25 feet, this pump will NOT work. 4. Periodic cleaning of pump is required to maintain performance of the pump. Follow the cleaning steps listed below: a. Unplug the power cord. b. Remove the 3 screws at the bottom of the pump. c. Remove the volute cover. Note the alignment marks. d. Remove the gasket. Note how the openings in the gasket align with the openings in the pump base. e. Remove the debris and make sure the impeller turns freely. f. Replace the gasket making sure the openings are aligned. g. Replace the volute cover. h. Replace the 3 screws. 1. The motor housing of the pump is completely sealed and requires no service. Disassembly of the motor housing or alteration of the power cord could result in fatal electrical shock. 2. Verify pump is operating correctly. a. Disconnect pump from power source. b. Disconnect discharge hose from pump. c. Immerse pump in a bucket or tub of water. d. Plug power cord into a grounded 115 volt AC power outlet. If pump operates correctly proceed to step #3. If pump does NOT Figure 1 Water Level 25 Ft. Max. Water Level 2 Operating Instructions and Parts Manual For Replacement Parts, call 1-800-237-0987 Please provide following information: Address parts correspondence to: -Model number Wayne Water Systems -Serial number (if any) 100 Production Drive -Part description and number as shown in parts list Harrison, OH 45030 U.S.A. 1 2 3 4 5 6 Ref. No.DescriptionTSC130/250TSC160Qty. 1 Power cord 31006-002 31006-002 1 2 Discharge fitting 15875 15875-002 1 3 Outer housing with o-ring 28053-001 28053-001 1 19023-001 19023-001 1 4 Impeller 23097 23097 1 5 Volute gasket 23122 23122 1 6 Volute cover with screen 28056-001 28056-002 1 3 Operating Instructions and Parts Manual Limited Warranty For one year from the date of purchase, Wayne Water Systems Division ("Wayne") will repair or replace, at its option, for the original purchaser any part or parts of its Sump Pumps or Water Pumps (“Product”) found upon examination by Wayne to be defective in materials or workmanship. Please call Wayne (800-237-0987) for instructions or see your dealer. Be prepared to provide the model number and the serial number when exercising this warranty. All transportation charges on Products or parts submitted for repair or replacement must be paid by purchaser. This L...
Otros modelos de este manual:Fontanería - 351301-001 (120.63 kb)