Iniciar sesión:
Votos - 4, Puntuación media: 3.8 ( )

Manual de usuario Delta, modelo SELECTRONIC 7095.121

Fabricar: Delta
Tamaño del archivo: 1.01 mb
Nombre del archivo:
Idioma del manual:
Enlace gratuito para este manual disponible en la parte inferior de la página



Resumen del manual


Fig. 4a. 2. Push the COVER TUBE (1) into the WALL ESCUTCHEON (2). Slide both onto the SUPPLY PIPE (3). Fig. 4b. 3. Push the COVER TUBE (1) in to expose the threads of the supply pipe. Fig. 4c. With a wrench thread the SUPPLY STOP (4) onto the SUPPLY PIPE (3). Align and tighten. Fig. 4c. 4. Pull COVER TUBE (1) against SUPPLY STOP (4) and push WALL ESCUTCHEON (2) against finished wall. 3 INSTALL DOWN TUBE AND VACUUM BREAKER; Fig. 5 1. Place the SPUD FLANGE (1) over the spud on the Fixture. 2. Thread SPUD COUPLING NUT (2) onto Spud. Make sure SEAL WASHER (3) and FRICTION WASHER (4) are installed. Do not tighten fully. 3. Insert the DOWN TUBE (5) into the SPUD COUPLING NUT (2) and push it down. Note: If cutting Down Tube (5) to size, note that Critical Line (C/L) on Vacuum Breaker must typically be 6" (152mm) above fixture. Consult Code for details. Fig.3 CENTER LINE OF FIXTURE SPUD FINISHED WALL FILE EDGES SOLDER ADAPTER ADAPTER 32mm (1-1/4) A (A-B)= BC CLEAN Fig. 4 Fig. 4a Fig. 4b Fig. 4c 1 1 4 2 3 TEFLON TAPE FINISHED WALL X X2 1 2 5 Fig. 5 3 4 1-1/2" TOP SPUD M968699 Rev. 1.14 3 FLUSH OUT SUPPLY LINES; Fig. 6 Fig. 6 1. Remove COVER (1) from SUPPLY STOP (2). 2. With a flat blade screwdriver open SUPPLY STOP (2). 3. Turn on water supply to flush line of any debris or sediment. 4. Close SUPPLY STOP (2) and replace COVER (1). 1 CLOCKWISE CLOSES CONTROL STOP COUNTER-CLOCKWISE OPENS CONTROL STOP REMOVE COVER 2 2 45LEFT OR RIGHT HAND INSTALLATION; Fig. 7 The UNIT is shipped with the inlet flange on the right side. If needed, the orientation can be reversed by following the steps below. 1. Loosen SET SCREW (1) with 2.5mm Hex Wrench (4) in back of top half of FLUSH VALVE (2). Fig. 7a. 2. Rotate TOP (2) to the right and pull off. Fig. 7b. 3. Rotate bottom half of FLUSH VALVE (3) 180°. Fig. 7b. 4. Replace TOP (2) and rotate until key engages than tighten SET SCREW (1). Fig. 7c, 7d. 4 M968699 Rev. 1.14 1 4 Fig. 7a Fig. 7c Fig. 7d Fig. 7 4 KEY 2 2 1 3 Fig. 7b 180° RED+ BLACK- 2 INSTALL FLUSH VALVE; Fig. 8a Fig. 8a & 8b 1. As shown in Fig. 8a, insert the side INLET FLANGE (1) on the FLUSH VALVE (2) into the SUPPLY STOP (3). Lubricate the INLET FLANGE O-RING (4) with water if necessary. Lightly tighten COUPLING NUT (5). Fig. 8a. Important: Do not use lubricants (other than water) or any type of thread sealing paste or tape. 2. Align the FLUSH VALVE (2) (Fig. 8b) directly above the DOWN TUBE (7) and VACUUM BREAKER COUPLING NUT (6). Make sure that GASKET (10) is installed. Note: There is a +13mm, -6mm (+1/2, -1/4) tolerance for the 121mm (4-3/4) dimension. Fig. 8b. 3. Pull the DOWN TUBE (7) up to meet the threaded 3 2 5 1 4 FLUSH VALVE CONNECTION (8) and hand tighten the VACUUM BREAKER COUPLING NUT (6). Align all components of the flush valve assembly. Fig. 8b. 4. Lightly tighten the COUPLING NUT (5) connection first, then the VACUUM BREAKER COUPLING NUT (6) and finally the SPUD COUPLING NUT (9)....

Otros modelos de este manual:
Fontanería - SELECTRONIC 6065.121 (1.01 mb)
Fontanería - SELECTRONIC 6065.122 (1.01 mb)
Fontanería - SELECTRONIC 6065.122 (1.01 mb)
Fontanería - SELECTRONIC 6065.121 (1.01 mb)

Comentarios



Tu reseña
Tu nombre:
Introduzca dos números de la imagen:
capcha





Categoría