Iniciar sesión:
Votos - 4, Puntuación media: 4 ( )

Manual de usuario ADTRAN, modelo Enterprise Filter R3000IR

Fabricar: ADTRAN
Tamaño del archivo: 3.3 mb
Nombre del archivo: c7a4282f-843d-4b09-ab59-5e28578d66e7.pdf
Idioma del manual:en
Enlace gratuito para este manual disponible en la parte inferior de la página



Resumen del manual


Never disassemble, tamper with, or attempt to repair the server. Doing so may cause smoke, fire, electrical shock, serious physical injury, or death. Do not insert objects through openings in the chassis. Doing so could result in a short circuit that might cause a fire or an electrical shock. Do not operate the server in an explosive atmosphere, in the presence of flammable gases. To ensure proper cooling, always operate the server with its covers in place. Do not block any openings on the chassis. Do not place the server near a heater. Always exit the software application properly before turning off the server to ensure data integrity. Do not expose the server to rain or use near water. If liquids of any kind should leak into the chassis, power down the server, unplug it, and contact 8e6 Technologies technical support. Disconnect power from the server before cleaning the unit. Do not use liquid or aerosol cleaners. AC Power Cord and Cable Precautions Warning: The AC power cord for the server must be plugged into a grounded, power outlet. Do not modify or use a supplied AC power cord if it is not the exact type required in the region where the server will be installed and used. Replace the cord with the correct type. Route the AC power cord and cables away from moving parts and foot traffic. Do not allow anything to rest on the AC power cord and cables. Never use the server if the AC power cord has been damaged. Always unplug the AC power cord before removing the unit for servicing. Electrical Safety Precautions Warning: Heed the following safety precautions to protect yourself from harm and the server from damage: CAUTION: Dangerous voltages associated with the 100-240 V AC power supply are present inside the unit. To avoid injury or electrical shock, do not touch exposed connections or components while the power is on. To prevent damage to the server, read the information in this document for selection of the proper input voltage. Do not wear rings or wristwatches when troubleshooting electrical circuits. To avoid fire hazard, use only the specified fuse(s) with the correct type number, voltage, and current ratings. Only qualified service personnel should replace fuses. Qualified service personnel should be properly grounded when servicing the unit. Qualified service personnel should perform a safety check after any service is performed. Motherboard Battery Precautions Caution: The battery on the motherboard should not be replaced without following instructions provided by the manufacturer. Only qualified service personnel should replace batteries. The battery contains energy and, as with all batteries, a malfunction can cause heat, smoke, or fire, release toxic materials, or cause burns. Do not disassemble, puncture, drop, crush, bend, deform, submerge or modify the battery. Do not incinerate or expose to heat above 140°F (60°C). There is a danger of explosion if the battery on the motherboard is installed upside down, which will reverse its polarities. CAUTION: DANGER OF EXPLOSION IF BATTERY IS INCORRECTLY REPLACED. REPLACE ONLY WITH THE SAME OR EQUIVALENT TYPE RECOMMENDED BY THE MANUFACTURER. DISPOSE OF THE USED BATTERIES ACCORDING TO THE MANUFACTURER’S INSTRUCTIONS. ATTENTION: IL Y A DANGER D’EXPLOSION S’IL Y A REPLACEMENT INCORRECT DE LA BATTERIE, REMPLACER UNIQUEMENT AVEC UNE BATTERIE DU MEME TYPE OU D’UN TYPE EQUIVALENT RECOMMANDE PAR LE CONSTRUCTEUR. METTRE AU REBUT LES BATTERIES USAGEES CONFORMEMENT AUX INSTRUCTIONS DU FABRICANT. WARNING: Users in Member States should consult Article 20 of Directive 2006/66/EC of the European Parliament and of the Council before disposing the motherboard battery. Install the Server Step 1: Setup Procedures This step requires you to link the workstation to the R3000IR. You have the option of using the text-based Quick Start setup procedures described in Step 1A, or the Administrator console setup procedures described in Step 1B. Quick Start Setup Requirements The following hardware is required for the Quick Start setup procedures: R3000IR with AC power cord either one of two options: PC monitor with AC power cord and keyboard, or PC laptop computer with HyperTerminal and serial port cable (and USB DB9 serial adapter, if there is no serial port on your laptop) Go to Step 1A to execute Quick Start Setup Procedures. Administrator Console Setup Requirements The following hardware is required for the Administrator console setup procedures: R3000IR unit with AC power cord CAT-5E crossover cable PC laptop computer, or PC monitor with AC power cord and keyboard Go to Step 1B to execute Console Setup Procedures. Step 1A: Quick Start Setup Procedures Link the Workstation to the R3000IR Monitor and Keyboard Setup A. Connect the PC monitor and keyboard cables to the rear of the chassis (see Fig. 1). B. Turn on the PC monitor. C. Power on the R3000IR by dropping down the face plate and pressing the large button at the right of the front panel (see Fig. 2). Once the R3000IR is ...

Otros modelos de este manual:
Equipo de red - Enterprise Filter R3000IR (3.3 mb)
Equipo de red - Enterprise Filter R3000IR (3.3 mb)
Equipo de red - Enterprise Filter R3000IR (3.3 mb)

Comentarios



Tu reseña
Tu nombre:
Introduzca dos números de la imagen:
capcha





Categoría