Iniciar sesión:
Votos - 5, Puntuación media: 3.8 ( )

Manual de usuario Adder Technology, modelo AdderView CATx AVX4016IP

Fabricar: Adder Technology
Tamaño del archivo: 3.62 mb
Nombre del archivo:
Idioma del manual:en
Enlace gratuito para este manual disponible en la parte inferior de la página



Resumen del manual


The default startup string is ‘ATZS0=1’. Both the serial port speed and startup string settings can easily be altered during configuration - see Initial IP configuration for more details. The other serial settings are fixed at: No parity, 8 bit word and 1 stop bit. ... ........... .... ..... . ........ .... .... ... . .... .. ... ... . Power in connection The.AdderView.CATx.unit.is. supplied.with.a.single.30W.power. adapter.which.is.sufficient.to.supply. any.configuration.of.the.unit..The. AdderView.CATx.IP.unit.has.two. power.input.sockets.to.allow.an. auxiliary.(redundant).power.adapter. to.be.connected..There.is.no.on/off. switch.on.the.unit,.so.operation. begins.as.soon.as.a.power.adapter. is.connected. Note: AdderView CATx units require a heavy duty power adapter at either or both power input connectors. Use only the adapter supplied with the unit or available under Adder part number: PSU-IEC-5V6A. Do not use the standard 10W adapters that are supplied with other Adder products, such as the X100. To connect the power supply 1. Attach.the.output.lead.from.the.power.adapter.to.the.MAIN PWR IN.socket. on.the.rear.panel.of.the.AdderView.CATx. AdderView CATx rear panel output lead from power adapter 2. Connect.the.IEC.connector.of.the.supplied.country-specific.power.lead.to. the.socket.of.the.power.adapter. 3. Connect.the.power.lead.to.a.nearby.main.supply.socket. 4. Repeat.steps.1.to.3.for.the.auxiliary.power.adapter.(using.the.AUX PWR IN. socket),.if.a.backup.supply.is.required. Note: Both the AdderView CATx and its power supply generate heat when in operation and will become warm to the touch. Do not enclose them or place them locations where air cannot circulate to cool the equipment. Do not operate the equipment in ambient temperatures exceeding 40 degrees Centigrade. Do not place the products in contact with equipment whose surface temperature exceeds 40 degrees Centigrade. Using two power supplies will ensure that each power supply takes less load and run at a correspondingly cooler temperature. ... ........... .... ..... . ........ .... .... ... . .... .. ... ... . Power control port The.AdderView.CATx.IP.models.provide. a.serial.port.for.connection.to.one.or. more.optional.power.control.units.. This.allows.you.to.control.the.mains. power.being.supplied.to.the.connected. computer(s).so.that.an.authorised.user. can,.if.necessary,.perform.a.complete. remote.cold.reboot.on.a.failed.system. The.control.connector.of.the.first.power.switch.is.attached,.via.serial.cable,.to. the.rear.panel.of.the.AdderView.CATx.IP..Any.additional.power.switches.are. then.attached.via.a.‘daisy-chain’.arrangement.to.the.first.power.switch..Each. power.switch.box.is.then.given.a.unique.address.and.access.to.each.power.port. (8.ports.on.each.power.switch.box).is.gained.using.a.combination.of.the.switch. box.address.and.the.port.number.. ‘Daisy-chain’ Power to computerBox , port - address: Power control switch connections boxes Box Box Box Box The.power.ports.are.connected.to.the.power.inputs.of.each.computer.system. and.the.power.switch.box(es).are.then.connected.to.a.mains.power.supply. IMPORTANT: Power switching devices have a maximum current rating. It is essential to ensure that the total current drawn by the equipment connected to the power switching device does not exceed the current rating of the power switching device. You must also ensure that the current drawn from any mains socket does not exceed the current rating of the mains socket. Setting.up,.configuring.and.using.power.switching.requires.three.main.steps: •. Connect.and.address.the.switch.boxes.• •. Configure the power strings •. Operate.power.switching.via configuration menu.or.via viewer To connect and address the switch boxes Note: The AdderView CATx IP unit can be powered on during this procedure, however, the switch boxes should be switched off. 1. Mount.up.to.four.switch.boxes.in.positions.where.they.are.close.to.the. computer.systems.that.they.will.control.and.not.too.distant.from.the. AdderView.CATx.IP.unit.(preferably.within.2.5.metres). 2. Use.a.serial.cable.with.an.RJ9.and.a.9-pin.D-type.connector.(see.Appendix 7.for.specification)..Attach.the.RJ9.plug.to.the.socket.marked.IN.on.the.first. switch.box..Attach.the.other.end.to.the.socket.marked.POWER CONTROL.on. the.AdderView.CATx.IP. AdderView CATx rear panel Serial cable to first power switch box 3. For.each.of.the.remaining.switch.boxes.(if.used),.use.a.serial.cable.with.RJ9. connectors.at.both.ends.(see.Appendix 7.for.specification)..Attach.one. end.to.the.socket.marked.OUT.of.the.previous.box.and.the.other.end.to.the. socket.marked.IN.of.the.next.box.. 4. Set.the.addressing.switches.on.each.switch. box.using.the.two.micro.switches.marked. ‘Slct’.on.the.front.panel..The.box.connected. directly.to.the.AdderView.CATx.IP.is.Box.1. and.so.on,.down.the.daisy-chain.line.to.Box. 4.at.the.end. 5. Attach.IEC.to.IEC.power.leads.between. Box Switch Switch . . 1... Off. Off . 2. On. Off . 3. Off. On . 4. On. ...

Otros modelos de este manual:
Equipo de red - AdderView CATxIP 1000 (3.62 mb)
Equipo de red - AdderView CATx AVX4016 (3.62 mb)
Equipo de red - AdderView CATx CATX-PS2 (3.62 mb)
Equipo de red - AdderView CATx CATX-PS2A (3.62 mb)

Comentarios



Tu reseña
Tu nombre:
Introduzca dos números de la imagen:
capcha





Categoría