Iniciar sesión:
Votos - 2, Puntuación media: 4 ( )

Manual de usuario Agilent Technologies, modelo N9360A

Fabricar: Agilent Technologies
Tamaño del archivo: 879.75 kb
Nombre del archivo: N9360-90002.pdf
Idioma del manual:en
Enlace gratuito para este manual disponible en la parte inferior de la página



Resumen del manual


Connecting a Printer: •Connect a printer to print a hardcopy of the test results if required. Inserting the TEST SIM for GSM mobile phone or TEST USIM for a W-CDMA mobile phone: •Insert the Test SIM (Subscriber Identity Module) supplied by Agilent into the GSM mobile phone or the test USIM (Universal Subscriber Identity Module) supplied by Agilent into the W-CDMA mobile phone before performing any test. •GSM/W-CDMA/cdma2000 Mobile Phone Repair Process Figure 3-2 Mobile Phone Repair Process 4 GSM System For Go/No-Go Testing 4-2 For Pinpointing Failures 4-3 For Troubleshooting 4-5 RF Channels 4-7 MS Power Control / Power Class 4-7 RX Level 4-9 RX Quality 4-10 Figure 4-1 [Automatic Test: Stand-by] Screen Figure 4-2 [Automatic Test: Stand-by] Screen 2Press the Screen>> softkey to set screen mode to Detail or Value. 3Rotate the knob to place the cursor in one of the Pass/Fail cells on the detail screen or test result cells on the value screen. Then, press the knob. 4One of the following measurement result screens is displayed according to your selection in step 3. •To print the measurement results or to save them into a USB memory device, press the Print Screen softkey. •In the graphical display, you can use the marker function to read data points by rotating the knob. •The zoom function is available on the power ramp graph display by pressing the Zoom Off/On softkey. Figure 4-3 Various [Automatic Test: Stand-by] Screens 5To display other measurement result screens or to finish analysis, press the Return softkey to display the previous screen. Figure 4-4 [Manual Test (GSM): Stand-by] Screen 1Press the Manual Test softkey on the [Initial] screen. 2Move the cursor to the “Procedure” field and select a pre-defined test procedure. 3Turn the mobile phone on. 4Wait for the completion of Location Update. 5Press the BS Call softkey and respond to the call on the mobile phone when it is called. Or, dial an arbitrary number and press the Off Hook key on the mobile phone to start the MS Call. 6To start measurement while the left screen is displayed, refer to step 7. For detailed measurement at each measurement item, refer to step 8. Figure 4-5 Various [Manual Test (GSM): Stand-by] Screens 7While “Connection” is highlighted in the test flow, press the Trigger softkey to start single measurement or the Trigger Sing/Cont softkey to start continuous measurement. Press the Trigger Sing/Cont softkey again to terminate the continuous measurement. 8Place the cursor at one of the groups of the test items and press the knob or press the Spectrum Monitor softkey to display a measurement result screen according to your selection. Then, press the Trigger softkey to start single measurement or Trigger Sing/Cont softkey to start continuous measurement. Press the Trigger Sing/Cont softkey again to terminate the continuous measurement. 9In the graphical display, the marker function is available to read the data points by rotating the knob. On the power ramp graph display, the zoom function is also available. 10To display other measurement result screens, press the Return softkey to display the previous screen. To end the entire test, press the Release softkey to start the BS Release, or press the On Hook key on the mobile phone to finish the MS Release. RX Quality Table 4-6 RX Quality 5 W-CDMA System For Go/No-Go Testing 5-2 For Pinpointing Failures 5-3 For Troubleshooting 5-4 UARFCN 5-5 Mobile Phone Maximum Output Power 5-5 Figure 5-1 [Automatic Test: Stand-by] Screen 1Press the Automatic Test softkey on the [Initial] screen for W-CDMA system. 2Move the cursor to the “Procedure” field, and select a pre-defined test procedure. 3Press the Start softkey. 4Turn the mobile phone on. Wait for completion of Location Update. 5Operate the mobile phone as instructed in the table below. Each test flow step is highlighted as it runs. 6After completing the test, check the results on the screen. 7To print the measurement results or to save them into a USB memory device, press the More (1 of 2) softkey and then the Print Screen softkey. Figure 5-2 [Automatic Test: Stand-by] Screen 1Perform the steps described in “For Go/No-Go Testing.” 2Press the Screen>> softkey to set screen mode to Value. 3Check the values of the measurement results. Figure 5-3 [Manual Test: Stand-by] Screen 1Press the Manual Test softkey on the [Initial] screen. 2Move the cursor to the “Procedure” field and select a pre-defined test procedure. 3Turn the mobile phone on. 4Wait for the completion of Location Update. 5Select “RMC” for BS Call at the “BS Call” input field. 6Press the BS Call softkey. 7While “Connection (RMC)” is highlighted in the test flow, press the Trigger softkey to start single measurement or the Trigger Sing/Cont softkey to start continuous measurement. Press the Trigger Sing/Cont softkey again to terminate continuous measurement. 8Press the Release softkey to finish the Test. 6 cdma2000 System When "CDMA Mode" is set to MC-1x mode 6-2 When "CDMA Mode" is set to 1...


Comentarios



Tu reseña
Tu nombre:
Introduzca dos números de la imagen:
capcha





Categoría