Iniciar sesión:
Votos - , Puntuación media: ( )

Manual de usuario Agilent Technologies, modelo E4400-60597

Fabricar: Agilent Technologies
Tamaño del archivo: 105.7 kb
Nombre del archivo:

Idioma del manual:en

El documento se está cargando, por favor, espere
El documento se está cargando, por favor, espere

Resumen del manual


The default installation folder can be changed using the Browse button. 4. After installing both the PSG/ESG Upgrade Assistant 5.12 program and the selected firmware files, proceed to “Using the PSG/ESG Upgrade Assistant 5.12 with Firmware Files” on page 11. To install PSG/ESG Upgrade Assistant 5.12 and firmware files from CD-ROM 1. Insert the firmware upgrade CD-ROM into the computer’s CD-ROM drive. An autostart file should run automatically. 2. Once the PSG/ESG Upgrade Assistant 5.12 starts, proceed to “Using the PSG/ESG Upgrade Assistant 5.12 with Firmware Files” on page 11. Agilent Technologies Firmware Upgrade Kits E4400-60230 and E4400-60597 for PSG/ESG Signal Generators Firmware Upgrade Kits E4400-60230 and E4400-60597 for PSG/ESG Signal Generators Use the PSG/ESG Upgrade Assistant 5.12 with Firmware Files The PSG/ESG Upgrade Assistant 5.12 is used with firmware files to upgrade the firmware on PSG/ESG signal generators. NOTE For Agilent E44xxB ESG Signal Generators Models Only When upgrading Agilent E44xxB ESG signal generators from firmware versions earlier than B.03.20, the firmware must be upgraded in two steps: a. Upgrade from earlier firmware versions to B.03.20 using RS-232. b. Upgrade from B.03.20 to any newer version (> B.03.20) using RS-232 or GPIB. 1. From the program’s Setup Parameters dialog box, select the Connection Type to be either LAN, GPIB, or RS-232: • If LAN is selected (not available with Agilent E44xxB ESG signal generators), specify the settings for LAN Setup. Enter the IP address or the instrument name (alias name) that has been assigned to the signal generator. For example, the signal generator could be assigned an instrument name or an IP address such as 141.xxx.xxx.xxx (where each x can be any digit from 0 to 9). Each instrument name or IP address is assigned by a system administrator at your facility. (For further information, refer to the documentation that came with your LAN interface card or contact your system administrator.) • If GPIB is selected, specify the settings for GPIB Setup. Use GPIB Port 0 and Address 19. These values should correspond with the values that are set on your signal generator. For example, the signal generator is usually set to GPIB Port 0 and Address 19 and the GPIB interface card in the computer is usually set to GPIB Port 0 and Address 21. These values are chosen by convention, but any address in the range 0-30, inclusive, may be used. (For further information, refer to the documentation that came with your GPIB interface card.) • If RS-232 is selected (only for use with Agilent E44xxB ESG signal generators), specify the settings for RS-232 Setup. Use either COM Port 1, 2, 3, or 4; the COM port that is selected depends on the number of serial ports that are available on the PC model be used. — Main firmware must be loaded at a Baud Rate of 19200, but DSP code can be loaded at Baud Rates up to 57600. 2. Under Firmware Release, click the Browse button. 3. From the Select Release File dialog box, double-click the folder for the version of firmware that you would like to install (for example, double-click c_02_52_2002_nov). 4. When the folder opens, double-click the filename for the version of firmware that you would like to install (for example, c_02_52_e443xc.esg). a. Click the View Release Information button and review all firmware release information before downloading to the signal generator. b. From the program’s Setup Parameters dialog box, under Special Cases, select any items that may apply to the upgrade: • Select the Added New Hardware checkbox if new hardware has been added to the signal generator. Agilent Technologies Firmware Upgrade Kits E4400-60230 and E4400-60597 for PSG/ESG Signal Generators Check Signal Generator Functionality • Select the Recover Failed Upgrade checkbox if a previous firmware upgrade had been aborted or failed and a recovery is required. c. Click the Next button to proceed. 5. From the program’s Select Components dialog box: a. Under Selected Release, verify that the correct firmware version has been selected. • If the firmware version needs to be changed, use the Back button and return to step 3 of this procedure. b. Under Firmware Revision, verify that the version of the firmware designated as Installed is to be replaced by the version designated as New. • If an old version of firmware is to be installed, select the Allow Old Revisions checkbox. Note that installing old versions of firmware with new hardware may generate errors. c. Under Upgrade Selection, verify that all firmware components are to be upgraded. By default, all upgrade components are selected: • If you want to perform a partial upgrade and do not already know the requirements for each upgrade component, use the Back button and return to step 4 of this procedure. • If all components are not to be upgraded: 1. Click the Options button and review the cards installed in the signal generator along with their corresponding options. 2. Click the OK...

Otros modelos de este manual:
Equipo de red - E4400-60230 (105.7 kb)

Comentarios



Tu reseña
Tu nombre:
Introduzca dos números de la imagen:
capcha





Categoría