Iniciar sesión:
Votos - 3, Puntuación media: 4 ( )

Manual de usuario DCS, modelo DD-36SS

Fabricar: DCS
Tamaño del archivo: 898.5 kb
Nombre del archivo:
Idioma del manual:enfr
Enlace gratuito para este manual disponible en la parte inferior de la página



Resumen del manual


Press the Up/Down button to lower the unit. The Up/Down button must be pressed and held momentarily to raise or lower the plenum. This is a safety feature which protects against accidental activation when cleaning the plenum. For best results, start the Downdraft before cooking and allow the unit to operate for several minutes after cooking is complete to clear all smoke and odors from the kitchen. If using large pots, place them on the rear burner to insure proper ventilation. A higher fan setting may be required. CLEANING The metal grease filters should be cleaned frequently in hot detergent solution or washed in the dishwasher. The plenum and top strip should be cleaned with stainless steel cleaner. Abrasives and scouring agents can scratch stainless steel finishes and should not be used. USE WITH GAS COOKTOPS The DCS Downdraft Vent System is designed for safe use with gas cooktops and will not extinguish burners or pilots. The blower does not start operation until the plenum has reached the full upright position. Also, the blower stops operation as soon as the Up/Down switch is pressed to lower the unit. WARNING: If a spill occurs on the cooktop that allows liquids to seep inside the Downdraft, you must turn the Downdraft off immediately. It is possible to cause damage to the Downdraft if water is allowed inside the Downdraft while it is operating. ¦ Immediately turn “OFF” the Downdraft at the speed control located on the right hand side of the Downdraft. n Turn “OFF” the power supply to the Downdraft at the circuit breaker box or fuse box. ¦ Allow plenty of time for the Downdraft to dry naturally. Do not open the Downdraft to remove the water. Failure to follow these warnings could result in damage to the Downdraft. SAFETY MICROSWITCHES This Downdraft Vent System is designed with a safety microswitch behind the center of each grease filter. These microswitches prevent the blower and plenum-raising mechanism from operating when either of the grease filters is removed. It is very important to make sure that the grease filters are properly and firmly in place after cleaning. If the unit does not operate after replacing the grease filters, make sure the filters are properly installed and are making firm contact with the safety microswitches. Control knob 4 WIRING DIAGRAM SWITCH FAN N.O. BLK BLK ISWITCH SWITCH DOWN N.C. UP N.C. BLU GEAR MOTOR WHT SWITCH FILTER N.O. BLK BLK BLU BLK PUSH BUTTON N.O. 11 UF WHT BLK BLK BLU M WHT WHT BLOWER BLK BLK MOTOR 8/50K-A120 WHT BLK LINE IN 120 VAC 60 Hz WHT GRN BLK WIRING BOX SPEED CONTROL 5 SERVICE HOW TO OBTAIN SERVICE: Before you call for service: 1) Is the circuit breaker tripped or the fuse blown? 2) Is there a power outage in the area? 3) Are the grease filters properly installed? 4) Will the unit go up/down and the blow control is on? For warranty service, contact DCS Customer Care at (888) 281-5698. Before you call, please have the following information ready: n Model Number (can be found on right side of the blower motor box). n Serial Number (can be found on right side of the blower motor box). n Date of installation n A brief description of the problem Your satisfaction is of the utmost importance to us. If a problem cannot be resolved to your satisfaction, please write at: Write: Fisher & Paykel Appliances, Inc. Attention: DCS Customer Care 5900 Skylab Road Huntington Beach, CA 92647 6 WARRANTY LIMITED WARRANTY When you purchase a new DCS Ventilation Product for personal or consumer use you automatically receive a One year Limited Warranty covering parts and labor for the entire product, and a Five year Limited Warranty on the switches and motor (parts only) for servicing within the 48 mainland United States, Hawaii, Washington D.C and Canada. In Alaska the Limited Warranty is the same except that you must pay to ship the Product to the service shop or for the service technician’s travel to your home. Products for use in Canada must be purchased through the Canadian distribution channel to ensure regulatory compliance. If the Product is installed in a motor vehicle, boat or similar mobile facility, you receive the same One year Limited Warranty, but you must bring the vehicle, boat or mobile facility containing the Product to the service shop at your expense or pay the service technician’s travel to the location of the Product. FISHER & PAYKEL UNDERTAKES TO: Repair without cost to the owner either for material or labor any part of the Product, the serial number of which appears on the Product, which is found to be defective. In Alaska, you must pay to ship the Product to the service shop or for the service technician’s travel to your home. If the Product is installed in a motor vehicle, boat or similar mobile facility, you must bring it to the service shop at your expense or pay for the service technician’s travel to the location of the Product. If we are unable to repair a defective part of the Product after a reasonable number of attempts, at our option we ...

Otros modelos de este manual:
Equipo de red - DD-30SS (898.5 kb)

Comentarios



Tu reseña
Tu nombre:
Introduzca dos números de la imagen:
capcha





Categoría