Iniciar sesión:
Votos - 2, Puntuación media: 5 ( )

Manual de usuario AMX, modelo TPI-PRO-4

Fabricar: AMX
Tamaño del archivo: 3.8 mb
Nombre del archivo:
Idioma del manual:en
Enlace gratuito para este manual disponible en la parte inferior de la página



Resumen del manual


Panel Logs Page The Panel Logs page allow you to view and track the connection history of the panel. FIG. 51 Panel Logs page The elements of the Panel Logs page are described in the following table: Panel Logs Page Back Saves all changes and returns to the previous page. Connection Status icon The icon in the upper-right corner of each Setup page shows online/offline state of the panel to the master. •Bright red - disconnected •Bright green - connected. Blinks when a blink message is received to dark green every 5 seconds for half a second then go back to bright green. •Bright yellow - panel missed a blink message from the master. It will remain yellow for 3 missed blink messages and then turn red. It will return to green when a blink message is received. Note: A Lock appears on the icon if the panel is connected to a secured NetLinx Master. Connection Logs A history of all connections, attempts, and failures for the panel. Clear Clears the Connection Logs history. Refresh Refreshes the Connection Logs history. Page Indicates the current page of the Connection Logs. Use the Up and Down arrows to move from one page to the next. Checking the Panel Connection Logs 1.Press the Tools button in the Protected Setup Navigation Buttons section. This opens the Tools menu. 2.Within the Tools menu, press the Panel Logs button. All connection data is contained in the section Connection Logs. Refreshing the Panel Connections Log 1.Press the Tools button in the Protected Setup Navigation Buttons section. This opens the Tools menu. 2.Within the Tools menu, press the Panel Logs button. 3.Push the Refresh button. Clearing the Panel Connections Log 1.Press the Tools button in the Protected Setup Navigation Buttons section. This opens the Tools menu. 2.Within the Tools menu, press the Panel Logs button. 3.Push the Clear button. 4.Confirm your selection. Panel Statistics Page The options on the Panel Statistics page allow you to track the connection status for the panel. The Panel Statistics page tracks ICSP messages, Blink messages, Ethernet connection statistics, and Wireless connection statistics (FIG. 52). FIG. 52 Panel Statistics page The elements of the Panel Statistics page are described in the following table: Panel Statistics Page Back Saves all changes and returns to the previous page. Connection Status icon The icon in the upper-right corner of each Setup page shows online/offline state of the panel to the master. •Bright red - disconnected •Bright green - connected. Blinks when a blink message is received to dark green every 5 seconds for half a second then go back to bright green. •Bright yellow - panel missed a blink message from the master. It will remain yellow for 3 missed blink messages and then turn red. It will return to green when a blink message is received. Note: a Lock appears on the icon if the panel is connected to a secured NetLinx Master. ICSP Messages Messages sent between the master and the touch panel; it is the protocol they use to communicate to each other. Total •Received - The total ICSP messages received by the panel. •Processed - The total ICSP messages processed by the panel. •Dropped - The total ICSP messages dropped by the panel. Last 15 Minutes •Received - The total ICSP messages received by the panel in the last 15 minutes. •Processed - The total ICSP messages processed by the panel in the last 15 minutes. •Dropped - The total ICSP messages dropped by the panel in the last 15 minutes. Blink Messages The master sends this message once every 5 seconds to all connected devices. Total •Received - The total Blink messages received by the panel. •Missed - The total Blink messages missed by the panel. Last 15 Minutes •Received - The total Blink messages received by the panel in the last 15 minutes. •Missed - The total Blink messages missed by the panel in the last 15 minutes. Ethernet Statistics The Ethernet connection statistics for the panel. Clear Clears all panel connection statistics. Refresh Refreshes all panel connection statistics. Checking the Panel Statistics 1.Press the Tools button in the Protected Setup Navigation Buttons section. This opens the Tools menu. 2.Within the Tools menu, press the Panel Statistics button. All connection statistics are contained on this page, e.g., Received, Processed, and Dropped ICSP Messages. Refreshing the Panel Statistics 1.Press the Tools button in the Protected Setup Navigation Buttons section. This opens the Tools menu. 2.Within the Tools menu, press the Panel Statistics button. 3.Push the Refresh button. Clearing the Panel Statistics 1.Press the Tools button in the Protected Setup Navigation Buttons section. This opens the Tools menu. 2.Within the Tools menu, press the Panel Statistics button. 3.Push the Clear button. 4.Confirm your selection. Connection Utility Page The options on the Connection Utility page allows you to view query and response statistics for your connection. FIG. 53 Connection Utility page The elements of the Connection Utili...

Otros modelos de este manual:
Equipo de red - TPI-PRO-2 (3.8 mb)

Comentarios



Tu reseña
Tu nombre:
Introduzca dos números de la imagen:
capcha





Categoría