Iniciar sesión:
Votos - 1, Puntuación media: 5 ( )

Manual de usuario Advantech, modelo Data Acquisition Modules ADAM 4000

Fabricar: Advantech
Tamaño del archivo: 3.65 mb
Nombre del archivo: ADAM-4000_Manual_Ed_10_7.pdf
Idioma del manual:en
Enlace gratuito para este manual disponible en la parte inferior de la página



Resumen del manual


5-58 ADAM 4000 Series User’s Manual 4011, 4011D, 4012 Chapter 5 @AARE Name Read Event Counter command Description The addressed module is instructed to return its event counter value. Syntax @AARE(cr) @ is a delimiter character. AA (range 00-FF) represents the 2-character hexadecimal address of an analog input module. RE is the Reads Event Counter command. (cr) represents terminating character, carriage return (0Dh). Response !AA(data)(cr) if the command was valid. There is no response if the module detects a syntax error or communication error or if the specified address does not exist. ! delimiter character indicates a valid command was received. AA represents the 2-character hexadecimal address of the responding analog input module. (data) represents the stored value, from ‘00000’ to ‘65535’ (The max value that can be held by the counter register is 65535). The number 65535 is held when the actual total counts exceed this number. (cr) represents terminating character, carriage return (0Dh). Example command: @08RE(cr) response: !0832011(cr) The command instructs the module at address 08h to return its counter value. The module responds that its counter value equals 32011. 5-59 ADAM 4000 Series User’s Manual 4011, 4011D, 4012 @AACE Name Clear Event Counter command Description The addressed module is instructed to reset its event counter to zero. Syntax @AACE(cr) @ is a delimiter character. AA (range 00-FF) represents the 2-character hexadecimal address of an analog input module. CE is the Clear Event Counter command. (cr) represents terminating character, carriage return (0Dh). Response !AA(cr) if the command was valid. There is no response if the module detects a syntax error or communication error or if the specified address does not exist. ! delimiter character indicates a valid command was received. AA represents the 2-character hexadecimal address of the responding analog input module. (cr) represents terminating character, carriage return (0Dh). Example command: @09CE(cr) response: !09(cr) The command instructs the module at address 09h to set its event counter to zero. The module responds that its counter has been reset. 5-60 ADAM 4000 Series User’s Manual Chapter 5 5.4 Excitation Voltage Output Command Set Command Syntax Command Name Description I/O module $AA6 Get Excitation Voltage Output Value Returns either last value sent to specified module by $AA7 command, or start-up output voltage. 4016 $AA7 Excitation Voltage Output Direct output excitation voltage data to a specified module 4016 $AAS Start-up Voltage Output Configuration Stores a default value in a specified module. The output value will take effect upon startup. 4016 $AAE Trim Calibration Trims specified module a number of units up/down 4016 $AAA Zero Calibration Tells the module to store parameters for zero calibration 4016 $AAB Span Calibration Tells the module to store parameters for span calibration 4016 5-61 ADAM 4000 Series User’s Manual $AA6 Name Get Excitation Voltage Output Value command Description The addressed strain gauge input module is instructed to return the latest output value it received from Excitation Voltage Output command. If the module hasn’t received an Excitation Voltage Output command since startup, it will return its Start-up Output value. Syntax $AA6(cr) $ is a delimiter character. AA (range 00-FF) represents the 2-character hexadecimal address of the strain gauge input module. 6 is the Get Excitation Voltage Output command. (cr) is the terminating character, carriage return (0Dh) Response !AA(data)(cr) if the command is valid. ?AA(cr) if an invalid command was issued. There is no response if the module detects a syntax error or communication error or if the specified address does not exist. ! delimiter character indicates a valid command was received. ? delimiter character indicates the command was invalid. AA (range 00-FF) represents the 2-character hexadecimal address of the strain gauge input module. (data) is the value that is returned by analog output channel. The format of the data is in engineering unit. (cr) is the terminating character, carriage return (0Dh) Example command: $0A6(cr) response: !0A+03.000(cr) The command tells the strain gauge input module at address 0Ah to return the last excitation voltage output value it received from an Excitation Voltage Output command. The strain gauge input module returns the value +03.000V. 5-62 ADAM 4000 Series User’s Manual 4016 Chapter 5 $AA7 Name Excitation Voltage Output command Description Send a value to the analog output channel of the addressed strain gauge input module. Upon receipt, the analog output channel will output this value. Syntax $AA7(data)(cr) $ is a delimiter character. AA (range 00-FF) represents the 2-character hexadecimal address of the strain gauge input module. 7 is the Excitation Voltage Output command. (data) is the value that has to be output through the analog output channel. The data format is engineering unit and the range is...

Otros modelos de este manual:
Equipo de red - Data Acquisition Modules ADAM 4000 (3.65 mb)

Comentarios



Tu reseña
Tu nombre:
Introduzca dos números de la imagen:
capcha





Categoría