Iniciar sesión:
Votos - 1, Puntuación media: 4 ( )

Manual de usuario Porter-Cable, modelo 444

Fabricar: Porter-Cable
Tamaño del archivo: 192.54 kb
Nombre del archivo: ff2ccc91-63d3-4fb8-99ec-83bb84c7bbf0.pdf
Idioma del manual:en
Enlace gratuito para este manual disponible en la parte inferior de la página



Resumen del manual


These masks and replaceable filters are readily available at major hardware stores. Be sure the mask fits. Beards and facial hair may keep the masks from sealing properly. Change filters often. DISPOSABLE PAPER MASKS ARE NOT ADEQUATE. 7. Keep food and drink out of the work area. Wash hands, arms, and face and rinse mouth before eating or drinking. Do not smoke or chew gum or tobacco in the work area. 8. Clean up all removed paint and dust by wet mopping the floors. Use a wet cloth to clean all walls, sills and any other surfaces where paint or dust is clinging. DO NOT SWEEP, DRY DUST OR VACUUM. Use a high phosphate detergent or trisodium (TSP) to wash and mop areas. 9. At the end of each work session, put the paint chips and debris in a double plastic bag, close it with tape or twist ties and dispose properly. Such preventive safety measures reduce the risk of exposure. 10. Remove protective clothing and work shoes in the work area to avoid carrying dust into the rest of the dwelling. Wash work clothes separately. Wipe shoes off with a wet rag, then wash that rag with the work clothes. Wash hair and body thoroughly with soap and water. SAVE THESE INSTRUCTIONS! 8 MOTOR Many Porter-Cable tools will operate on either D.C., or single phase 25 to 60 cycle A.C. current and voltage within plus or minus 5 percent of that shown on the specification plate on the tool. Several models, however, are designed for A.C. current only. Refer to the specification plate on your tool for proper voltage and current rating. Do not operate your tool on a current on which the voltage is not within correct limits. Do not operate tools rated A.C. only on D.C. current. To do so may seriously damage the tool. EXTENSION CORD SELECTION If an extension cord is used, make sure the conductor size is large enough to prevent excessive voltage drop which will cause loss of power and possible motor damage. A table of recommended extension cord sizes will be found in this section. This table is based on limiting line voltage drop to 5 volts (10 volts for 230 volts) at 150% of rated amperes. If an extension cord is to be used outdoors, it must be marked with the suffix WA or W following the cord type designation. For example – SJTW-A to indicate it is acceptable for outdoor use. RECOMMENDED EXTENSION CORD SIZES FOR USE WITH PORTABLE ELECTRIC TOOLS Length of Cord in Feet 115V 25 Ft. 50 Ft. 100 Ft. 150 Ft. 200 Ft. 250 Ft. 300 Ft. 400 Ft. 500 Ft. 230V 50 Ft. 100 Ft. 200 Ft. 300 Ft. 400 Ft. 500 Ft. 600 Ft. 800 Ft. 1000 Ft. Nameplate Ampere Rating 0-2 18 18 18 16 16 14 14 12 12 2-3 18 18 16 14 14 12 12 10 10 3-4 18 18 16 14 12 12 10 10 8 4-5 18 18 14 12 12 10 10 8 8 5-6 18 16 14 12 10 10 8 8 6 6-8 18 16 12 10 10 8 6 6 6 8-10 18 14 12 10 8 8 6 6 4 10-12 16 14 10 8 8 6 6 4 4 12-14 16 12 10 8 6 6 6 4 2 14-16 16 12 10 8 6 6 4 4 2 16-18 14 12 8 8 6 4 4 2 2 18-20 14 12 8 6 6 4 4 2 2 SAVE THESE INSTRUCTIONS! 9 CARTON CONTENTS * Sander * Standard sanding pad * Profile mounting plates * Set of 9 different sanding profiles * Assorted profile sanding sheets * Carrying case FUNCTIONAL DESCRIPTION FOREWORD The Porter-Cable Profile Sander provides an “in-line” sanding motion that permits sanding of corners, profiles, and other areas that are inaccessible to other power sanders. ASSEMBLY NOTE: This tool is shipped completely assembled. No assembly time or tools are required. OPERATION PREPARATION FOR SANDING NOTE: A wide variety of accessory pads, profile holders, and profiles is available to fit the Porter-Cable Profile Sander. Please refer to your Porter-Cable Catalog to determine which of these items are supplied as standard equipment with each particular Profile Sander Package. All of these items are available as accessories, and they may be used with any Porter-Cable Model 444 Profile Sander. SELECTING A PAD OR PROFILE MOUNTING PLATE Select the sanding pad or profile holder that best fits your application: Fig. 1. A B C D E Fig. 1 A. Diamond Pad for PSA Abrasives: The pointed tip of this pad is used for sanding into corners and intricately shaped areas. Precut PSA abrasives are used with this pad (Fig. 2). 10 B. Diamond Pad for Hook & Loop Abrasives: The pointed tip of this pad is used for sanding into corners and intricately shaped areas. Precut, Hook & Loop Abrasives with dust extraction holes are used with this pad. The optional 14449 dust wand (and an external vacuum source), can also be used with this pad to provide dust collection (Fig. 3). Fig. 2 Fig. 3 C. Single Profile Mounting Plate: This plate is used to mount any one of the profiles in a vertical position, centered under the Profile Sander (Fig. 4). Special PSA Abrasives are available in precut sheets or in rolls that can be cut-to-fit the various profiles. D. Angled Profile Mounting Plate: This plate is used to mount any one of the profiles at a 30° outward angle on either the right or left side of the tool. (Fig. 5) This plate permits the profiles to be used in areas that are inaccessible with the...

Otros modelos de este manual:
Máquinas de rectificar - 444vs (192.54 kb)

Comentarios



Tu reseña
Tu nombre:
Introduzca dos números de la imagen:
capcha





Categoría