Iniciar sesión:
Votos - , Puntuación media: ( )

Manual de usuario Shindaiwa, modelo EB344EF13

Fabricar: Shindaiwa
Tamaño del archivo: 1.37 mb
Nombre del archivo: c74a4903-1e79-4cbc-b479-f9fb4c2ee6c0.pdf

Idioma del manual:en

El documento se está cargando, por favor, espere
El documento se está cargando, por favor, espere

Resumen del manual


WARNING! WARNING Moving parts can amputate fingers or cause severe injuries. Keep hands, clothing and loose objects away from all openings. • ALWAYS stop engine, disconnect spark plug, and make sure all moving parts have come to a complete stop before removing obstructions, clearing debris, or servicing unit. • DO NOT start or operate unit unless all guards and protective covers are properly assembled to unit. • NEVER reach into any opening while the engine is running. Moving parts may not be visible through openings. The Properly Equipped Operator Always wear eye protection such as a face shield Wear hearing protection Wear a dust mask to reduce the risk of inhalation injuries. or goggles while operating this unit. Never operate the blower when visibility is poor. Wear close-fitting clothing to protect legs and arms. Gloves offer added protection and are strongly recommended. Do not wear clothing or jewelry that could get caught in machinery or underbrush. Secure hair so it is above shoulder level. NEVER wear shorts! when operating this unit. Keep a proper footing and do not overreach. Maintain your balance at all times during operation. Always be aware of the strength and direction of the blower discharge stream. Never direct the Wear appropriate footwear blower discharge stream toward such as non-skid boots or shoes. people or animals! Do not wear open-toed shoes or sandals and never operate the unit while barefoot! Figure 1 Be Aware of the Working Environment Reduce the risk of bystanders being struck by flying debris. Make sure bystanders or observers outside the 15 m (50 feet) “danger zone” wear eye protection. Avoid long-term 15 m (50 feet)—that’s Make sure no one is within operation in very hot about 16 paces—of an or very cold weather. operating blower. 15 METERS Never operate the blower if any component parts Do not direct the air blast are damaged, towards bystanders. The high loose, or missing! objects at great speed causing possible eye injury. air flow could blow small Be extremely careful of Be constantly alert slippery terrain, especially for objects and debris that during rainy weather. could be thrown from Never operate this blower the air blast and bounced on a roof, ledge or ladder. from a hard surface. Figure 2 5 Unit Description Figure 3 IMPORTANT! Safety and Operation Information Labels: Make sure all information labels are undamaged and readable. Immediately replace damaged or missing information labels. New labels are available from your local authorized Shindaiwa dealer. Recoil/ Starter Handle Fuel Primer Bulb Throttle Lever Throttle Limiter Lever Exhaust Air Cleaner Cover Fuel Filler Cap Ignition Switch Nozzle Blower Tube Contents Using Figure 3 as a guide, familiarize yourself with the blower and its components. Understanding the unit helps ensure top performance, longer service life, and safer operation. Before assembling the blower, make sure you have all required components. • Power unit and blower assembly. • This Owner’s/Operator’s Manual and a tool kit containing a tool bag, T-Wrench, 4 mm Hex Wrench. IMPORTANT! The terms “left”, “left-hand”, “LH”; “right”, “right-hand”, and “RH”; “front” and “rear” refer to directions as viewed by the operator during normal operation. Carefully inspect all components for damage. Specifications Model EB344 Engine Type 4-cycle air cooled gasoline engine, vertical cylinder Engine Bore x Stroke 38 mm x 30 mm (1.5 in x 1.18 in.) Engine Displacement 34.0 cc (2.07 in3) Unit Weight (without blower tube) Less Fuel 5.3 kg (11.7 lb) Unit Dimensions (LxWxH) 895 x 256 x 374 mm (35 x 10 x 15 in) Fuel Tank Capacity 0.6 liter/20.0 oz. Fuel/oil ratio 50:1 with *ISO-L-EGD or JASO FD class engine oil Carburetor Diaphragm type Ignition CDI (Capacitor Discharge Ignition) Spark Plug NGK CMR5H Electrode Gap 0.6 mm (.024 in) Torque 16.7 - 18.6 Nm / 148-165 in • lbs Air Cleaner Dry Element Muffler Type Spark arrestor muffler or spark arrestor muffler with catalyst Starting Method Recoil Starter Stopping Method Slide Switch (grounding type) Air Speed 89 m/sec. (199 MPH) Air Volume 9.6 m3 /min. (340 cu. ft./min.) Sound Level @ 50 ft. dB(A) scale per ANSI B175.2 71 dB(A) Idle Speed (RPM) 3,000 Wide Open Throttle (RPM) 8,700 Specifications are subject to change without notice. IMPORTANT! This spark ignition system complies with the Canadian standard ICES-002. Emission Control (Exhaust & Evaporative) EPA 2010 and Later and/or C.A.R.B. TIER III The emission control system for the engine is EM/TWC (Engine Modification and 3-way Catalyst) and for the fuel tank the Control System is EVAP (Evaporative Emissions) or N (for nylon tank). Evaporative emission may be applicable to California models only. An Emission Control Label is located on the unit. (This is an EXAMPLE ONLY; information on label varies by engine FAMILY). PRODUCT EMISSION DURABILITY (EMISSION COMPLIANCE PERIOD) The 300 hour emission compliance period is the time span selected by the manufacturer certifying th...

Otros modelos de este manual:
Los sistemas de ventilación - X7501930200 (1.37 mb)

Comentarios



Tu reseña
Tu nombre:
Introduzca dos números de la imagen:
capcha





Categoría