Iniciar sesión:
Votos - 4, Puntuación media: 3.8 ( )

Manual de usuario Datalogic Scanning, modelo DS6400

Fabricar: Datalogic Scanning
Tamaño del archivo: 6.33 mb
Nombre del archivo: e12dad9d-e4ea-4ebb-9166-cc8acce0b374.pdf
Idioma del manual:en
Enlace gratuito para este manual disponible en la parte inferior de la página



Resumen del manual


CONDITIONS Code = Interleaved 2/5 or Code 39 PCS = 0.90 Pitch angle = 0° Skew angle = 10° - 20° Tilt angle = 0° The curves show the minimum and maximum radial distance. 60 56 130 64 (in) 160 150 52 (cm) 140 120 110 100 90 80 36 32 40 44 48 28 70 0 55 60 65 70 75 80 85 90 95 100 105 110 115 (cm) 22 24 26 28 30 32 34 36 38 40 42 44 46 (in) 60 50 40 24 20 16 Max. Reading Distance Reading distance Focus Distance 120 125 68 170 72 180 48 50 130 52 Min. Reading Distance Figure 90 – Standard Model 0.30 mm / 12 mils Radial Distance DS6400-100-0XX - Resolution: 0.38 mm/15 mils The diagram shows a global reading area, which includes all possible focus positions, and the reading area obtained for the DS6400-100-0XX operating with focus position = 140 cm and barcode density of 0.38 mm (15 mils). It is possible to obtain the minimum and maximum distance values by referring to the radial distance curves displayed in Figure 92. 8 4 12 (in) 0 16 20 24 28 32 36 (in) 0 40 50 60 70 80 90 100 110 (cm) 50 40 30 20 0 (cm) 10 -10 0 -20 -30 -40 16 20 -16 -20 -12 -8 -4 120 130 40 44 48 52 -50 -24 24 60 140 150 56 60 Global Reading Area -60 Focus Position = 140 cm 160 64 170 180 68 72 28 70 -28 -70 Figure 91 – Standard Model 0.38 mm / 15 mils Reading Diagram Note: (0,0) is the center of the laser beam output window. CONDITIONS Code = Interleaved 2/5 or Code 39 PCS = 0.90 Pitch angle = 0° Skew angle = 10° - 20° Tilt angle = 0° The curves show the minimum and maximum radial distance. 60 56 130 64 (in) 160 150 52 (cm) 140 120 110 100 90 80 36 32 40 44 48 28 70 0 50 60 70 80 90 100 110 120 130 140 150 160 170 (cm) 20 24 28 32 36 40 44 48 52 56 60 64 68 (in) 60 50 40 24 20 16 Max. Reading Distance Reading distance Focus Distance 180 68 170 72 180 72 40 16 Min. Reading Distance Figure 92 – Standard Model 0.38 mm / 15 mils Radial Distance DS6400-100-0XX - Resolution: 0.50 mm/20 mils The diagram shows a global reading area, which includes all possible focus positions, and the reading area obtained for the DS6400-100-0XX operating with focus position = 120 cm and barcode density of 0.50 mm (20 mils). It is possible to obtain the minimum and maximum distance values by referring to the radial distance curves displayed in Figure 94. 8 4 12 (in) 0 16 20 24 28 32 36 (in) 0 40 50 60 70 80 90 100 110 (cm) 50 40 30 20 0 (cm) 10 -10 0 -20 -30 -40 16 20 -16 -20 -12 -8 -4 120 130 40 44 48 52 -50 -24 24 60 140 150 56 60 Global Reading Area -60 Focus Position = 120 cm 160 64 170 180 68 72 28 70 -28 -70 190 76 200 80 Figure 93 – Standard Model 0.50 mm / 20 mils Reading Diagram Note: (0,0) is the center of the laser beam output window. CONDITIONS Code = Interleaved 2/5 or Code 39 PCS = 0.90 Pitch angle = 0° Skew angle = 10° - 20° Tilt angle = 0° The curves show the minimum and maximum radial distance. 64 60 140 68 (in) 170 160 56 (cm) 150 130 120 110 100 90 40 36 44 48 52 32 80 0 50 60 70 80 90 100 110 120 130 140 150 160 170 (cm) 20 24 28 32 36 40 44 48 52 56 60 64 68 (in) 70 60 50 28 24 20 Max. Reading Distance Reading distance Focus Distance 180 72 180 76 190 72 40 16 80 200 Min. Reading Distance Figure 94 – Standard Model 0.50 mm / 20 mils Radial Distance 4.4.2 DS6400 Oscillating Mirror Model DS6400-105-0XX - Resolution: 0.20 mm/8 mils The diagram shows a global reading area, which includes all possible focus positions, and the reading area obtained for the DS6400-105-0XX operating with focus position = 60 cm and barcode density of 0.20 mm (8 mils). It is possible to obtain the minimum and maximum distance values by referring to the radial distance curves displayed in Figure 96. 8 6 10 10 (in) 0 14 16 18 20 22 24 (in) 0 35 40 45 50 55 60 65 70 (cm) 35 30 25 20 4 (cm) 15 5 0 -5 -10 -15 12 14 -4 -6 -2 0 2 75 80 26 28 30 32 -8 -20 16 40 85 90 95 100 34 36 38 40 Global Reading Area -25 -30 -35 -40 -10 -12 -14 -16 Focus Position = 60 cm Figure 95 – Oscillating Mirror Model 0.20 mm / 8 mils Reading Diagram Note: (0,0) is the center of the laser beam output window. CONDITIONS Code = Interleaved 2/5 or Code 39 PCS = 0.90 Pitch angle = 0° Skew angle = 10° - 20° Tilt angle = 0° The curves show the minimum and maximum radial distance. 36 85 (in) 34 (cm) 90 80 75 70 65 60 26 24 28 30 32 22 55 0 40 45 50 55 60 65 70 75 80 85 90 (cm) 0 16 18 20 22 24 26 28 30 32 34 36 (in) 50 45 40 20 18 16 Min. Reading Distance Max. Reading Distance Reading distance Focus Distance Figure 96 - Oscillating Mirror Model 0.20 mm / 8 mils Radial Distance DS6400-105-0XX - Resolution: 0.25 mm/10 mils The diagram shows a global reading area, which includes all possible focus positions, and the reading area obtained for the DS6400-105-0XX operating with focus position = 95 cm and barcode density of 0.25 mm (10 mils). It is possible to obtain the minimum and maximum distance values by referring to the radial distance curves displayed in Figure 98. 8 4 12 (in) 0 12 16 20 24 28 32 (in) 0 30 40 50 60 70 80 90 100 (cm) 50 40 30 20 0 (cm) 10 -10 0 -20 -30 -40 16 20 -16 -20 -12 -8 -4 110 120 36 40...


Comentarios



Tu reseña
Tu nombre:
Introduzca dos números de la imagen:
capcha





Categoría