Iniciar sesión:
Votos - 4, Puntuación media: 4 ( )

Manual de usuario Baracoda, modelo BRR-L

Fabricar: Baracoda
Tamaño del archivo: 325.43 kb
Nombre del archivo:
Idioma del manual:en
Enlace gratuito para este manual disponible en la parte inferior de la página



Resumen del manual


The BRR should have been previously set in the “No data loss mode” ON. REAL TIME without ACK beep and buffersiation. Forces the RoadRunners in Real Time mode (without data acknowledgement). Erases all codes in memory. The BRR should have been previously set in the “No data loss mode” ON. © Baracoda 2007 8/29 RoadRunners BRR-L & BRR-LA Programming guide Nov 2007 2.5.2/ Batch mode BATCH MODE. Forces the RoadRunners in Batch mode. Erases all codes in memory. When in batch mode, The BRR will wait the appropriate command in order to start uploading the barcodes: this command can come • from the Baracoda Manager • from reading the “discharge” barcode here after If this barcode is read when the reader is in batch mode and connected, the reader will automatically upload to the host all the data in its memory. If not in batch mode and not connected, the BRR-L will ignore this barcode. • For CPU firmware versions <3.16, only the following upload barcode is available: Upload batch data When scanning this barcode, the BRR will send all barcodes in memory using the Baracoda header, with “no data loss mode” OFF. .. For CPU firmware versions .3.16, this upload barcode is available: Upload batch data with no data loss mode This upload process consists in switching temporarily the BRR into Real time with “no data loss mode” ON (all the barcodes in memory will be sent using the no data loss protocol). Then the BRR switches back to batch mode when all the barcodes are properly sent. © Baracoda 2007 9/29 RoadRunners BRR-L & BRR-LA Programming guide Nov 2007 2.6/ Cradle / RS232 jack 2.6.1/ Cradle By default, the scanner Bluetooth is always ON. (It wasn’t the case for CPU version < 3.00) Disable dock UART (*) 2.6.2/ RS232 jackTo communicate with the scanner through the RS232 cable instead of Bluetooth way, you have to scan this barcode. Enable Dock UART Note : When the RS232 cable is not connected, it is possible to communicate with the scanner over Bluetooth. 2.7/ Buzzer and Led Settings You can use these options to enable or disable the buzzer and / or the Led. You can also invert the led position. LED ON (*) LED OFF Parameters are : Baud rate : 115200 Parity : none Data bits : 8 Stop bit : 1 LED CONFIG : default (*) LED CONFIG : inverted Good read beep on (*) Good read beep off ACK beep on (*) ACK beep off Beep level volume = HIGH (*) Beep level Volume = LOW © Baracoda 2007 10/29 RoadRunners BRR-L & BRR-LA Programming guide Nov 2007 2.8/ Bluetooth commands 2.8.1/ Bluetooth name You can change the scanner Bluetooth name; name that you see during a search of Bluetooth peripheral. (Feature enabled for CPU firmware version > 3.00) Set BT Name End of config Read « Set BT name » label START Read intermediary label Corresponding to the next character to set for the BT Name (from Appendix 1) Finished ? Read « END of config » label END NO YES © Baracoda 2007 11/29 RoadRunners BRR-L & BRR-LA Programming guide Nov 2007 2.8.2/ Sniff settings The higher the Sniff period, the higher is the latency and the smaller is the power consumption. Default value is 150ms. Sniff period = 150ms (*) Sniff period = 100ms Sniff period = 200ms Sniff period = 300ms Sniff period = 500ms 2.8.3/ Power emission settings You can configure your scanner to work at 20 dBm (default setting) or 10 dBm. Due to local laws, you may not use 20 dBm in some countries Power = 10dBm Power = 20dBm(*) 2.8.4/ Security (code PIN) settings Some BT device will not accept connections with devices that do not have a security code. Disable BT security code Enable BT security code (*) © Baracoda 2007 12/29 RoadRunners BRR-L Programming guide dec 2006 2.9/ Prefix and suffix The barcode string can be added a prefix, a postprefix, a suffix and/or a postsuffix. These can come as described below: prefix postprefix barcode suffix postsuffix 2.9.1/ Prefix/suffix You can add a prefix and/or a suffix (strings of more than 32 characters will not be accepted) to every barcode sent to the host device. There is no prefix/suffix in default settings. PREFIX on SUFFIX on PREFIX off (*) SUFFIX off (*) Read « Set Suffix (prefix) » label START Read intermediary label Corresponding to the next character to set for the suffix (appendix 1 of this document) Finished * ? Read « END of config » label END NO YES Programming procedure for “set suffix (prefix)” option. *= max length of the Suffix (Prefix) is 32 characters Set prefix Set suffix End of configuration © Baracoda 2006 13/29 RoadRunners BRR-L Programming guide dec 2006 2.9.2/ Postrefix/postsuffix You can add a postprefix and/or a postsuffix (strings of more than 32 characters will not be accepted) to every barcode sent to the host device. (Feature enabled for CPU firmware version . 3.16) There is no postprefix/postsuffix in default settings. POST PREFIX on POST PREFIX off (*) POST SUFFIX on POST SUFFIX off (*) Read « Set postprefix (postsuffix) » label START Read intermediary label Corresponding to the next character to set for the postprefix/postsuf...

Otros modelos de este manual:
escáner / copiadora / impresora multifunción - BBR-LA (325.43 kb)

Comentarios



Tu reseña
Tu nombre:
Introduzca dos números de la imagen:
capcha





Categoría